Manisha B. Sinha , Meryl Rachel John , Joseph Abraham Poonuraparampil , Human Prasad Sinha
{"title":"与内窥镜手术相关的骨性Kambin三角的尺寸","authors":"Manisha B. Sinha , Meryl Rachel John , Joseph Abraham Poonuraparampil , Human Prasad Sinha","doi":"10.1016/j.mjafi.2022.12.018","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div><span>Endoscopic procedures nowadays are successful, minimally invasive, and safer, with fewer intraoperative and postoperative complications<span> and shorter hospital stays. Kambin's triangle (KT) is the three-dimensional configuration that is used as a transforaminal anatomical corridor for epidural steroid injections and endoscopic surgeries for various lumbar pathologies. This study aims to estimate the dimensions of KT and diameter of the </span></span>cannula for the transforaminal surgical approaches using KT in the Chhattisgarh population.</div></div><div><h3>Methods</h3><div><span>Seven human cadavers (three males and four females) were included in the study for observing KT. Dissection was done to carefully clear landmarks, including the vertebral bodies, </span>intervertebral disc<span>, exiting nerve root, and superior articular process. Base<span> (a horizontal plane passing through the superior border of the caudal vertebra) and height (along the superior articular process of the inferior vertebra in line with the articular facet) were measured. Hypotenuse, semiperimeter of the triangle, area of triangle, diameter, and area of the inscribed circle were calculated.</span></span></div></div><div><h3>Results</h3><div>Height, base, and inscribed circle diameter increased from L1-L2 to L4-L5 then decreased to L5-S1. There was no statistically significant difference between males and females. The safest admissible cannula diameter according to the current study that can be used at all levels in KT was 6.06 mm.</div></div><div><h3>Conclusion</h3><div>This study provides the safest cannula size to be considered in the patients of the Chhattisgarh population during transforaminal approaches in the lumbar area. Minimally invasive surgery and shorter hospitalization are vital criteria to evaluate any surgery these days.</div></div>","PeriodicalId":39387,"journal":{"name":"Medical Journal Armed Forces India","volume":"80 ","pages":"Pages S127-S134"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dimensions of bony Kambin's triangle pertaining to endoscopic procedure\",\"authors\":\"Manisha B. Sinha , Meryl Rachel John , Joseph Abraham Poonuraparampil , Human Prasad Sinha\",\"doi\":\"10.1016/j.mjafi.2022.12.018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div><span>Endoscopic procedures nowadays are successful, minimally invasive, and safer, with fewer intraoperative and postoperative complications<span> and shorter hospital stays. Kambin's triangle (KT) is the three-dimensional configuration that is used as a transforaminal anatomical corridor for epidural steroid injections and endoscopic surgeries for various lumbar pathologies. This study aims to estimate the dimensions of KT and diameter of the </span></span>cannula for the transforaminal surgical approaches using KT in the Chhattisgarh population.</div></div><div><h3>Methods</h3><div><span>Seven human cadavers (three males and four females) were included in the study for observing KT. Dissection was done to carefully clear landmarks, including the vertebral bodies, </span>intervertebral disc<span>, exiting nerve root, and superior articular process. Base<span> (a horizontal plane passing through the superior border of the caudal vertebra) and height (along the superior articular process of the inferior vertebra in line with the articular facet) were measured. Hypotenuse, semiperimeter of the triangle, area of triangle, diameter, and area of the inscribed circle were calculated.</span></span></div></div><div><h3>Results</h3><div>Height, base, and inscribed circle diameter increased from L1-L2 to L4-L5 then decreased to L5-S1. There was no statistically significant difference between males and females. The safest admissible cannula diameter according to the current study that can be used at all levels in KT was 6.06 mm.</div></div><div><h3>Conclusion</h3><div>This study provides the safest cannula size to be considered in the patients of the Chhattisgarh population during transforaminal approaches in the lumbar area. Minimally invasive surgery and shorter hospitalization are vital criteria to evaluate any surgery these days.</div></div>\",\"PeriodicalId\":39387,\"journal\":{\"name\":\"Medical Journal Armed Forces India\",\"volume\":\"80 \",\"pages\":\"Pages S127-S134\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Journal Armed Forces India\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0377123722002416\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Journal Armed Forces India","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0377123722002416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Dimensions of bony Kambin's triangle pertaining to endoscopic procedure
Background
Endoscopic procedures nowadays are successful, minimally invasive, and safer, with fewer intraoperative and postoperative complications and shorter hospital stays. Kambin's triangle (KT) is the three-dimensional configuration that is used as a transforaminal anatomical corridor for epidural steroid injections and endoscopic surgeries for various lumbar pathologies. This study aims to estimate the dimensions of KT and diameter of the cannula for the transforaminal surgical approaches using KT in the Chhattisgarh population.
Methods
Seven human cadavers (three males and four females) were included in the study for observing KT. Dissection was done to carefully clear landmarks, including the vertebral bodies, intervertebral disc, exiting nerve root, and superior articular process. Base (a horizontal plane passing through the superior border of the caudal vertebra) and height (along the superior articular process of the inferior vertebra in line with the articular facet) were measured. Hypotenuse, semiperimeter of the triangle, area of triangle, diameter, and area of the inscribed circle were calculated.
Results
Height, base, and inscribed circle diameter increased from L1-L2 to L4-L5 then decreased to L5-S1. There was no statistically significant difference between males and females. The safest admissible cannula diameter according to the current study that can be used at all levels in KT was 6.06 mm.
Conclusion
This study provides the safest cannula size to be considered in the patients of the Chhattisgarh population during transforaminal approaches in the lumbar area. Minimally invasive surgery and shorter hospitalization are vital criteria to evaluate any surgery these days.
期刊介绍:
This journal was conceived in 1945 as the Journal of Indian Army Medical Corps. Col DR Thapar was the first Editor who published it on behalf of Lt. Gen Gordon Wilson, the then Director of Medical Services in India. Over the years the journal has achieved various milestones. Presently it is published in Vancouver style, printed on offset, and has a distribution exceeding 5000 per issue. It is published in January, April, July and October each year.