Vania Callista, Yuskar Lase, Widjojo Adi Prakoso, Mulia Orientilize
{"title":"spe连接的数字研究对象是带有和没有混凝土填充料的小帽","authors":"Vania Callista, Yuskar Lase, Widjojo Adi Prakoso, Mulia Orientilize","doi":"10.29103/tj.v12i1.681","DOIUrl":null,"url":null,"abstract":"According to SNI 8640, spun pile as part of lower structure is not designed with the concept of performance-based design (PBD) because of repair issues, although PBD has been allowed for lower structures in other countries. According to the 2017 seismic zone, the increasing seismic demand in Indonesia results in an inefficient foundation design if inelastic behavior of foundation due to a big earthquake is not allowed. Three full scales of spun pile connections were tested with lateral cyclic loading to explore the inelastic behavior of foundation. A finite element (FE) analysis using Abaqus was conducted for further study. Due to low number of spun pile’s shear reinforcement (spiral) produced in Indonesia, the confinement effect of spiral model is compared with hoops model. Finite element analysis was also done to investigate the behavior difference of hollow spun pile and spun pile with concrete infill in terms of strength, ductility, and performance levels of spun pile’s connection.","PeriodicalId":52898,"journal":{"name":"Teras Jurnal Jurnal Teknik Sipil","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"STUDI NUMERIK SAMBUNGAN SPUN PILE TERHADAP PILE CAP DENGAN DAN TANPA BETON PENGISI AKIBAT PEMBEBANAN SIKLIK\",\"authors\":\"Vania Callista, Yuskar Lase, Widjojo Adi Prakoso, Mulia Orientilize\",\"doi\":\"10.29103/tj.v12i1.681\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"According to SNI 8640, spun pile as part of lower structure is not designed with the concept of performance-based design (PBD) because of repair issues, although PBD has been allowed for lower structures in other countries. According to the 2017 seismic zone, the increasing seismic demand in Indonesia results in an inefficient foundation design if inelastic behavior of foundation due to a big earthquake is not allowed. Three full scales of spun pile connections were tested with lateral cyclic loading to explore the inelastic behavior of foundation. A finite element (FE) analysis using Abaqus was conducted for further study. Due to low number of spun pile’s shear reinforcement (spiral) produced in Indonesia, the confinement effect of spiral model is compared with hoops model. Finite element analysis was also done to investigate the behavior difference of hollow spun pile and spun pile with concrete infill in terms of strength, ductility, and performance levels of spun pile’s connection.\",\"PeriodicalId\":52898,\"journal\":{\"name\":\"Teras Jurnal Jurnal Teknik Sipil\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Teras Jurnal Jurnal Teknik Sipil\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29103/tj.v12i1.681\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Teras Jurnal Jurnal Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29103/tj.v12i1.681","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
STUDI NUMERIK SAMBUNGAN SPUN PILE TERHADAP PILE CAP DENGAN DAN TANPA BETON PENGISI AKIBAT PEMBEBANAN SIKLIK
According to SNI 8640, spun pile as part of lower structure is not designed with the concept of performance-based design (PBD) because of repair issues, although PBD has been allowed for lower structures in other countries. According to the 2017 seismic zone, the increasing seismic demand in Indonesia results in an inefficient foundation design if inelastic behavior of foundation due to a big earthquake is not allowed. Three full scales of spun pile connections were tested with lateral cyclic loading to explore the inelastic behavior of foundation. A finite element (FE) analysis using Abaqus was conducted for further study. Due to low number of spun pile’s shear reinforcement (spiral) produced in Indonesia, the confinement effect of spiral model is compared with hoops model. Finite element analysis was also done to investigate the behavior difference of hollow spun pile and spun pile with concrete infill in terms of strength, ductility, and performance levels of spun pile’s connection.