{"title":"UPLC法结合设计分析质量和绿色分析技术评估匹伐他汀和依折麦布","authors":"Hemanth Kumar Chanduluru, Abimanyu Sugumaran","doi":"10.1556/1326.2021.00949","DOIUrl":null,"url":null,"abstract":"\n The current study explores a design and development of the simple, fast, green and selective novel method of UPLC to quantify pitavastatin and ezetimibe simultaneously. The combined approach of Green Analytical Method with Quality by Design-based risk assessment was done using the Ishikawa fishbone diagram followed by a rotatable central composite design used for the optimization. The optimal chromatographic separation was attained through a mobile phase of 72: 28% v/v ethanol and 0.1% orthophosphoric acid (pH 3.5), with a 0.31 mL min−1 flow rate. The developed UPLC-PDA method was sensitive and specific for pitavastatin and ezetimibe, with linearity ranging from 2 to 30, 10–150 μg mL−1 with an R2 of 0.9999 and 0.9997, respectively. The forced degradation study of stability-indicating assay results shows the degradation in respective stress conditions. The developed UPLC method was validated and found to have sensible results with good linearity, accuracy and precision. Further, the greenness was evaluated using five states of art metrics like NEMI, GAPI, AES, AMGS, and AGREE metrics and found the greenest results. Based on the results we concluded that the developed UPLC method could be efficient for the simultaneous determination of pitavastatin and ezetimibe in bulk and tablet dosage.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2021-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Estimation of pitavastatin and ezetimibe using UPLC by a combined approach of analytical quality by design with green analytical technique\",\"authors\":\"Hemanth Kumar Chanduluru, Abimanyu Sugumaran\",\"doi\":\"10.1556/1326.2021.00949\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The current study explores a design and development of the simple, fast, green and selective novel method of UPLC to quantify pitavastatin and ezetimibe simultaneously. The combined approach of Green Analytical Method with Quality by Design-based risk assessment was done using the Ishikawa fishbone diagram followed by a rotatable central composite design used for the optimization. The optimal chromatographic separation was attained through a mobile phase of 72: 28% v/v ethanol and 0.1% orthophosphoric acid (pH 3.5), with a 0.31 mL min−1 flow rate. The developed UPLC-PDA method was sensitive and specific for pitavastatin and ezetimibe, with linearity ranging from 2 to 30, 10–150 μg mL−1 with an R2 of 0.9999 and 0.9997, respectively. The forced degradation study of stability-indicating assay results shows the degradation in respective stress conditions. The developed UPLC method was validated and found to have sensible results with good linearity, accuracy and precision. Further, the greenness was evaluated using five states of art metrics like NEMI, GAPI, AES, AMGS, and AGREE metrics and found the greenest results. Based on the results we concluded that the developed UPLC method could be efficient for the simultaneous determination of pitavastatin and ezetimibe in bulk and tablet dosage.\",\"PeriodicalId\":7130,\"journal\":{\"name\":\"Acta Chromatographica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2021-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Chromatographica\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1556/1326.2021.00949\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2021.00949","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 9

摘要

本研究探索了一种简单、快速、绿色和选择性的UPLC新方法的设计和开发,该方法可同时定量匹伐他汀和依折麦布。绿色分析方法与基于设计质量的风险评估相结合的方法是使用Ishikawa鱼骨图进行的,然后是用于优化的可旋转中心复合材料设计。最佳色谱分离是通过72∶28%v/v乙醇和0.1%正磷酸(pH 3.5)的流动相实现的 mL最小−1流速。所开发的UPLC-PDA方法对匹伐他汀和依折麦布敏感且特异,线性范围为2至30,10–150 μg mL−1,R2分别为0.9999和0.9997。稳定性指示测定结果的强制降解研究显示了在各自的应力条件下的降解。对所开发的UPLC方法进行了验证,发现该方法具有良好的线性、准确度和精密度,结果合理。此外,使用五种最先进的指标,如NEMI、GAPI、AES、AMGS和AGREE指标,对绿色度进行了评估,并发现了最绿色的结果。基于这些结果,我们得出结论,所开发的UPLC方法可以有效地同时测定本体和片剂中的匹伐他汀和依折麦布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimation of pitavastatin and ezetimibe using UPLC by a combined approach of analytical quality by design with green analytical technique
The current study explores a design and development of the simple, fast, green and selective novel method of UPLC to quantify pitavastatin and ezetimibe simultaneously. The combined approach of Green Analytical Method with Quality by Design-based risk assessment was done using the Ishikawa fishbone diagram followed by a rotatable central composite design used for the optimization. The optimal chromatographic separation was attained through a mobile phase of 72: 28% v/v ethanol and 0.1% orthophosphoric acid (pH 3.5), with a 0.31 mL min−1 flow rate. The developed UPLC-PDA method was sensitive and specific for pitavastatin and ezetimibe, with linearity ranging from 2 to 30, 10–150 μg mL−1 with an R2 of 0.9999 and 0.9997, respectively. The forced degradation study of stability-indicating assay results shows the degradation in respective stress conditions. The developed UPLC method was validated and found to have sensible results with good linearity, accuracy and precision. Further, the greenness was evaluated using five states of art metrics like NEMI, GAPI, AES, AMGS, and AGREE metrics and found the greenest results. Based on the results we concluded that the developed UPLC method could be efficient for the simultaneous determination of pitavastatin and ezetimibe in bulk and tablet dosage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Chromatographica
Acta Chromatographica 化学-分析化学
CiteScore
4.00
自引率
0.00%
发文量
55
审稿时长
2.3 months
期刊介绍: Acta Chromatographica Open Access Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信