用于同时多组分光谱分析中校准标准混合物制备的流动批式分析仪

Q3 Physics and Astronomy
V. Visani, Sara Regina Ribeiro Carneiro de Barros, Heronides Adonias Dantas Filho, L. F. Almeida, R. Lima, W. Fragoso, T. C. Saldanha, M. C. U. Araújo
{"title":"用于同时多组分光谱分析中校准标准混合物制备的流动批式分析仪","authors":"V. Visani, Sara Regina Ribeiro Carneiro de Barros, Heronides Adonias Dantas Filho, L. F. Almeida, R. Lima, W. Fragoso, T. C. Saldanha, M. C. U. Araújo","doi":"10.1590/S0100-46702009000200005","DOIUrl":null,"url":null,"abstract":"The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simul- taneous determination of several chemical species. However, when this methodol- ogy is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high opera- tional cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu 2+ , Mn 2+ and Zn 2+ in polyvitaminic and polymineral pharmaceutical formula- tions, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the prepara- tion of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h -1 can be carried out with the proposed flow-batch analyser.","PeriodicalId":35894,"journal":{"name":"Ecletica Quimica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Flow-batch analyser for preparation of calibration standard mixtures in simultaneous multicomponent spectrometric analysis\",\"authors\":\"V. Visani, Sara Regina Ribeiro Carneiro de Barros, Heronides Adonias Dantas Filho, L. F. Almeida, R. Lima, W. Fragoso, T. C. Saldanha, M. C. U. Araújo\",\"doi\":\"10.1590/S0100-46702009000200005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simul- taneous determination of several chemical species. However, when this methodol- ogy is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high opera- tional cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu 2+ , Mn 2+ and Zn 2+ in polyvitaminic and polymineral pharmaceutical formula- tions, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the prepara- tion of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h -1 can be carried out with the proposed flow-batch analyser.\",\"PeriodicalId\":35894,\"journal\":{\"name\":\"Ecletica Quimica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ecletica Quimica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S0100-46702009000200005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ecletica Quimica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0100-46702009000200005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 3

摘要

多元校准技术在UV-VIS分子吸收光谱多组分分析中的应用是同时测定几种化学物质的有力工具。然而,当这种方法是手动完成时,它是缓慢和费力的,消耗大量的试剂和样品,容易受到污染,并且存在高的操作成本。为了克服这些缺点,本文提出了一种流量间歇分析仪。该分析仪是为自动制备标准校准和测试(或验证)混合物而开发的。以4-(2-铱偶氮)间苯二酚为试剂,用紫外-可见分光光度计和光电二极管阵列检测器,同时测定了聚乙烯和多矿物药物配方中的Cu2+、Mn2+和Zn2+。所提出的系统获得的结果与作为参考方法的火焰原子吸收光谱法获得的结果一致。使用拟议的分析仪,校准和测试混合物的制备可以在大约四小时内完成,而手动程序至少需要两天。此外,它比手动程序消耗更少的试剂和样品。在制备校准和测试混合物后,可以使用所提出的流动批次分析仪进行60个样品h-1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flow-batch analyser for preparation of calibration standard mixtures in simultaneous multicomponent spectrometric analysis
The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simul- taneous determination of several chemical species. However, when this methodol- ogy is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high opera- tional cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu 2+ , Mn 2+ and Zn 2+ in polyvitaminic and polymineral pharmaceutical formula- tions, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the prepara- tion of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h -1 can be carried out with the proposed flow-batch analyser.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ecletica Quimica
Ecletica Quimica Chemistry-Chemistry (all)
CiteScore
1.70
自引率
0.00%
发文量
32
审稿时长
28 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信