Saima Siddique, Resha Khanal, Amit N Vora, Hemal Gada
{"title":"经导管主动脉瓣置换术优化策略:尖头重叠、关节对齐、大小和定位","authors":"Saima Siddique, Resha Khanal, Amit N Vora, Hemal Gada","doi":"10.15420/usc.2021.24","DOIUrl":null,"url":null,"abstract":"<p><p>As transcatheter aortic valve replacement (TAVR) rapidly expands to younger patients and those at low surgical risk, there is a compelling need to identify patients at increased risk of post-procedural complications, such as paravalvular leak, prosthesis-patient mismatch, and conduction abnormalities. This review highlights the incidence and risk factors of these procedural complications, and focuses on novel methods to reduce them by using newer generation transcatheter heart valves and the innovative cusp-overlap technique, which provides optimal fluoroscopic imaging projection to allow for precise implantation depth which minimizes interaction with the conduction system. Preserving coronary access after TAVR is another important consideration in younger patients. This paper reviews the significance of commissural alignment to allow coronary cannulation after TAVR and discusses recently published data on modified delivery techniques to improve commissural alignment.</p>","PeriodicalId":37809,"journal":{"name":"US Cardiology Review","volume":" ","pages":"e10"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11588177/pdf/","citationCount":"0","resultStr":"{\"title\":\"Transcatheter Aortic Valve Replacement Optimization Strategies: Cusp Overlap, Commissural Alignment, Sizing, and Positioning.\",\"authors\":\"Saima Siddique, Resha Khanal, Amit N Vora, Hemal Gada\",\"doi\":\"10.15420/usc.2021.24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>As transcatheter aortic valve replacement (TAVR) rapidly expands to younger patients and those at low surgical risk, there is a compelling need to identify patients at increased risk of post-procedural complications, such as paravalvular leak, prosthesis-patient mismatch, and conduction abnormalities. This review highlights the incidence and risk factors of these procedural complications, and focuses on novel methods to reduce them by using newer generation transcatheter heart valves and the innovative cusp-overlap technique, which provides optimal fluoroscopic imaging projection to allow for precise implantation depth which minimizes interaction with the conduction system. Preserving coronary access after TAVR is another important consideration in younger patients. This paper reviews the significance of commissural alignment to allow coronary cannulation after TAVR and discusses recently published data on modified delivery techniques to improve commissural alignment.</p>\",\"PeriodicalId\":37809,\"journal\":{\"name\":\"US Cardiology Review\",\"volume\":\" \",\"pages\":\"e10\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11588177/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"US Cardiology Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15420/usc.2021.24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"US Cardiology Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15420/usc.2021.24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
As transcatheter aortic valve replacement (TAVR) rapidly expands to younger patients and those at low surgical risk, there is a compelling need to identify patients at increased risk of post-procedural complications, such as paravalvular leak, prosthesis-patient mismatch, and conduction abnormalities. This review highlights the incidence and risk factors of these procedural complications, and focuses on novel methods to reduce them by using newer generation transcatheter heart valves and the innovative cusp-overlap technique, which provides optimal fluoroscopic imaging projection to allow for precise implantation depth which minimizes interaction with the conduction system. Preserving coronary access after TAVR is another important consideration in younger patients. This paper reviews the significance of commissural alignment to allow coronary cannulation after TAVR and discusses recently published data on modified delivery techniques to improve commissural alignment.
期刊介绍:
US Cardiology Review (USC) is an international, US-English language, peer-reviewed journal that is published bi-annually and aims to assist time-pressured physicians to stay abreast of key advances and opinion in the area of cardiovascular disease. The journal comprises balanced and comprehensive review articles written by leading authorities. The journal provides updates on a range of salient issues to support physicians in developing their knowledge and effectiveness in day-to-day clinical practice. The journal endeavours to support the continuous medical education of specialist and general cardiologists and disseminate knowledge of the field to the wider cardiovascular community.