共线双脉冲激光诱导击穿光谱利用Nd:YAG激光器产生两个纳秒脉冲的调节能量比

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION
W. Skrzeczanowski, M. Skórczakowski, W. Zendzian
{"title":"共线双脉冲激光诱导击穿光谱利用Nd:YAG激光器产生两个纳秒脉冲的调节能量比","authors":"W. Skrzeczanowski, M. Skórczakowski, W. Zendzian","doi":"10.24425/mms.2023.144872","DOIUrl":null,"url":null,"abstract":"In the paper results of single-and double-pulse LIBS (Laser-Induced Breakdown Spectroscopy) measurements in collinear geometry are described. The experiments were performed using a unique self-made Nd:YAG laser operating in the Q-switching regime, where the laser transmission losses are switched. Such a laser allowed for an easy and quick change of the operating mode (one and two pulses), free shaping of the energy ratio of the two pulses (division of the energy of a single pulse into two parts) and a smooth change of the delay time between pulses in the range from 200 ns to 10 μ s. To our knowledge, such a laser was used in LIBS measurements for the first time. LIBS experiments revealed strong self-absorption depending on energy ratios carried out in the first and second laser pulse in the double-pulse mode. This was confirmed also by statistical factorial analysis of LIBS spectra. Plasma temperature and LIBS signal enhancement were measured both for energy proportions between the first and the second laser pulse and for the first-to-second-pulse delay.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2023-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Collinear double-pulse laser-induced breakdown spectroscopy using Nd:YAG laser generating two nanosecond pulses of regulated energy ratios\",\"authors\":\"W. Skrzeczanowski, M. Skórczakowski, W. Zendzian\",\"doi\":\"10.24425/mms.2023.144872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the paper results of single-and double-pulse LIBS (Laser-Induced Breakdown Spectroscopy) measurements in collinear geometry are described. The experiments were performed using a unique self-made Nd:YAG laser operating in the Q-switching regime, where the laser transmission losses are switched. Such a laser allowed for an easy and quick change of the operating mode (one and two pulses), free shaping of the energy ratio of the two pulses (division of the energy of a single pulse into two parts) and a smooth change of the delay time between pulses in the range from 200 ns to 10 μ s. To our knowledge, such a laser was used in LIBS measurements for the first time. LIBS experiments revealed strong self-absorption depending on energy ratios carried out in the first and second laser pulse in the double-pulse mode. This was confirmed also by statistical factorial analysis of LIBS spectra. Plasma temperature and LIBS signal enhancement were measured both for energy proportions between the first and the second laser pulse and for the first-to-second-pulse delay.\",\"PeriodicalId\":18394,\"journal\":{\"name\":\"Metrology and Measurement Systems\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrology and Measurement Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.24425/mms.2023.144872\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrology and Measurement Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.24425/mms.2023.144872","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了共线几何中单脉冲和双脉冲激光诱导击穿光谱测量的结果。实验采用了一种独特的自制Nd:YAG激光器,工作在q开关状态下,激光传输损耗被切换。这种激光器可以轻松快速地改变工作模式(单脉冲和双脉冲),自由地改变两个脉冲的能量比(将单个脉冲的能量分成两部分),并且在200 ns到10 μ s的范围内平滑地改变脉冲之间的延迟时间。据我们所知,这种激光器首次用于LIBS测量。LIBS实验显示,在双脉冲模式下,第一和第二激光脉冲的能量比决定了材料的自吸收强度。LIBS光谱的统计因子分析也证实了这一点。等离子体温度和LIBS信号增强测量了第一和第二激光脉冲之间的能量比例和第一到第二脉冲延迟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Collinear double-pulse laser-induced breakdown spectroscopy using Nd:YAG laser generating two nanosecond pulses of regulated energy ratios
In the paper results of single-and double-pulse LIBS (Laser-Induced Breakdown Spectroscopy) measurements in collinear geometry are described. The experiments were performed using a unique self-made Nd:YAG laser operating in the Q-switching regime, where the laser transmission losses are switched. Such a laser allowed for an easy and quick change of the operating mode (one and two pulses), free shaping of the energy ratio of the two pulses (division of the energy of a single pulse into two parts) and a smooth change of the delay time between pulses in the range from 200 ns to 10 μ s. To our knowledge, such a laser was used in LIBS measurements for the first time. LIBS experiments revealed strong self-absorption depending on energy ratios carried out in the first and second laser pulse in the double-pulse mode. This was confirmed also by statistical factorial analysis of LIBS spectra. Plasma temperature and LIBS signal enhancement were measured both for energy proportions between the first and the second laser pulse and for the first-to-second-pulse delay.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Metrology and Measurement Systems
Metrology and Measurement Systems INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
10.00%
发文量
0
审稿时长
6 months
期刊介绍: Contributions are invited on all aspects of the research, development and applications of the measurement science and technology. The list of topics covered includes: theory and general principles of measurement; measurement of physical, chemical and biological quantities; medical measurements; sensors and transducers; measurement data acquisition; measurement signal transmission; processing and data analysis; measurement systems and embedded systems; design, manufacture and evaluation of instruments. The average publication cycle is 6 months.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信