{"title":"tono - pachyometer测量角膜厚度与Scheimpflug- Placido地形图的相关性","authors":"Z. Ercan","doi":"10.17576/mh.2021.1602.12","DOIUrl":null,"url":null,"abstract":"Central corneal thickness (CCT) measurements are important for diagnosis, treatment, and surgery planning in ophthalmology. The purpose of this study was to see whether CCT measurements taken with Tono-pachymeter and Scheimpflug- Placido Topography had any significant differences. Tono-pachymeter and topography CCT measurements were taken (n=400). Inter-measurement agreement between them was determined using Bland-Altman Plot analysis. Age groups were also formed as group 1 (aged 18-50 years, 94 males, 106 females) and group 2 (age >51 years, 100 males, 100 females). Mean CCTs measured by Tonopachymeter and topography were 563.77 +±26.43 and 560.88 + 26.341 microns. Bland-Altman Plot analysis showed in total, 13 were above the upper limit and 5 were under the minimum limit of agreement with regression analysis showing no significant relationships (p=0.213). Group 1 had 7 above and 2 below from the limits of agreement. Group two had 9 above and 2 below from the limits of agreement. Both groups showed insignificant differences between devices (p=0.07 and p=0.86). Tono-pachymeter and Scheimpflug-Placido Topography give reliable CCT results within each other. However, since the limit of agreement ranges can still affect one-to-one patient evaluations, we recommend clinics that use these devices to not interchange measurements in practice.","PeriodicalId":80079,"journal":{"name":"Medicine & health","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation of Corneal Thickness Measurements Between Tono-pachymeter and Scheimpflug- Placido Topography\",\"authors\":\"Z. Ercan\",\"doi\":\"10.17576/mh.2021.1602.12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Central corneal thickness (CCT) measurements are important for diagnosis, treatment, and surgery planning in ophthalmology. The purpose of this study was to see whether CCT measurements taken with Tono-pachymeter and Scheimpflug- Placido Topography had any significant differences. Tono-pachymeter and topography CCT measurements were taken (n=400). Inter-measurement agreement between them was determined using Bland-Altman Plot analysis. Age groups were also formed as group 1 (aged 18-50 years, 94 males, 106 females) and group 2 (age >51 years, 100 males, 100 females). Mean CCTs measured by Tonopachymeter and topography were 563.77 +±26.43 and 560.88 + 26.341 microns. Bland-Altman Plot analysis showed in total, 13 were above the upper limit and 5 were under the minimum limit of agreement with regression analysis showing no significant relationships (p=0.213). Group 1 had 7 above and 2 below from the limits of agreement. Group two had 9 above and 2 below from the limits of agreement. Both groups showed insignificant differences between devices (p=0.07 and p=0.86). Tono-pachymeter and Scheimpflug-Placido Topography give reliable CCT results within each other. However, since the limit of agreement ranges can still affect one-to-one patient evaluations, we recommend clinics that use these devices to not interchange measurements in practice.\",\"PeriodicalId\":80079,\"journal\":{\"name\":\"Medicine & health\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicine & health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17576/mh.2021.1602.12\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine & health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17576/mh.2021.1602.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

角膜中央厚度(CCT)测量对眼科的诊断、治疗和手术计划都很重要。本研究的目的是观察用Tono-pachymeter和Scheimpflug- Placido地形图进行的CCT测量是否有显著差异。采用tono - pachyometer和地形CCT测量(n=400)。使用Bland-Altman图分析确定它们之间的测量间一致性。年龄分为1组(18 ~ 50岁,男94例,女106例)和2组(50 ~ 51岁,男100例,女100例)。Tonopachymeter和地形测量的平均CCTs分别为563.77±26.43和560.88±26.341微米。Bland-Altman图分析显示,共有13例高于一致性上限,5例低于一致性最低限度,回归分析显示无显著关系(p=0.213)。第1组有7个以上,2个以下。第二组有9个以上,2个以下。两组设备间差异均不显著(p=0.07和p=0.86)。Tono-pachymeter和Scheimpflug-Placido地形图相互之间提供可靠的CCT结果。然而,由于一致性范围的限制仍然会影响一对一的患者评估,我们建议使用这些设备的诊所在实践中不要交换测量结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Correlation of Corneal Thickness Measurements Between Tono-pachymeter and Scheimpflug- Placido Topography
Central corneal thickness (CCT) measurements are important for diagnosis, treatment, and surgery planning in ophthalmology. The purpose of this study was to see whether CCT measurements taken with Tono-pachymeter and Scheimpflug- Placido Topography had any significant differences. Tono-pachymeter and topography CCT measurements were taken (n=400). Inter-measurement agreement between them was determined using Bland-Altman Plot analysis. Age groups were also formed as group 1 (aged 18-50 years, 94 males, 106 females) and group 2 (age >51 years, 100 males, 100 females). Mean CCTs measured by Tonopachymeter and topography were 563.77 +±26.43 and 560.88 + 26.341 microns. Bland-Altman Plot analysis showed in total, 13 were above the upper limit and 5 were under the minimum limit of agreement with regression analysis showing no significant relationships (p=0.213). Group 1 had 7 above and 2 below from the limits of agreement. Group two had 9 above and 2 below from the limits of agreement. Both groups showed insignificant differences between devices (p=0.07 and p=0.86). Tono-pachymeter and Scheimpflug-Placido Topography give reliable CCT results within each other. However, since the limit of agreement ranges can still affect one-to-one patient evaluations, we recommend clinics that use these devices to not interchange measurements in practice.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信