用于识别和量化类风湿性关节炎患者高分辨率外围定量计算机断层扫描图像中皮质中断和骨侵蚀的开源图像分析工具。

Bone Pub Date : 2022-09-01 DOI:10.2139/ssrn.4169782
Mingjie Zhao, Justin J. Tse, Michael T. Kuczynski, Scott C. Brunet, Ryan Yan, K. Engelke, M. Peters, J. V. D. van den Bergh, B. van Rietbergen, K. Stok, C. Barnabe, Y. Pauchard, S. Manske
{"title":"用于识别和量化类风湿性关节炎患者高分辨率外围定量计算机断层扫描图像中皮质中断和骨侵蚀的开源图像分析工具。","authors":"Mingjie Zhao, Justin J. Tse, Michael T. Kuczynski, Scott C. Brunet, Ryan Yan, K. Engelke, M. Peters, J. V. D. van den Bergh, B. van Rietbergen, K. Stok, C. Barnabe, Y. Pauchard, S. Manske","doi":"10.2139/ssrn.4169782","DOIUrl":null,"url":null,"abstract":"Identification of bone erosions and quantification of erosion volume is important for rheumatoid arthritis diagnosis, and can add important information to evaluate disease progression and treatment effects. High-resolution peripheral quantitative computed tomography (HR-pQCT) is well suited for this purpose, however analysis methods are not widely available. The purpose of this study was to develop an open-source software tool for the identification and quantification of bone erosions using images acquired by HR-pQCT. The collection of modules, Bone Analysis Modules (BAM) - Erosion, implements previously published erosion analysis techniques as modules in 3D Slicer, an open-source image processing and visualization tool. BAM includes a module to automatically identify cortical interruptions, from which erosions are manually selected, and a hybrid module that combines morphological and level set operations to quantify the volume of bone erosions. HR-pQCT images of the second and third metacarpophalangeal (MCP) joints were acquired in patients with RA (XtremeCT, n = 14, XtremeCTII, n = 22). The number of cortical interruptions detected by BAM-Erosion agreed strongly with the previously published cortical interruption detection algorithm for both XtremeCT (r2 = 0.85) and XtremeCTII (r2 = 0.87). Erosion volume assessment by BAM-Erosion agreed strongly (r2 = 0.95) with the Medical Image Analysis Framework. BAM-Erosion provides an open-source erosion analysis tool that produces comparable results to previously published algorithms, with improved options for visualization. The strength of the tool is that it implements multiple image processing algorithms for erosion analysis on a single, widely available, open-source platform that can accommodate future updates.","PeriodicalId":93913,"journal":{"name":"Bone","volume":"1 1","pages":"116571"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Open-source image analysis tool for the identification and quantification of cortical interruptions and bone erosions in high-resolution peripheral quantitative computed tomography images of patients with rheumatoid arthritis.\",\"authors\":\"Mingjie Zhao, Justin J. Tse, Michael T. Kuczynski, Scott C. Brunet, Ryan Yan, K. Engelke, M. Peters, J. V. D. van den Bergh, B. van Rietbergen, K. Stok, C. Barnabe, Y. Pauchard, S. Manske\",\"doi\":\"10.2139/ssrn.4169782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Identification of bone erosions and quantification of erosion volume is important for rheumatoid arthritis diagnosis, and can add important information to evaluate disease progression and treatment effects. High-resolution peripheral quantitative computed tomography (HR-pQCT) is well suited for this purpose, however analysis methods are not widely available. The purpose of this study was to develop an open-source software tool for the identification and quantification of bone erosions using images acquired by HR-pQCT. The collection of modules, Bone Analysis Modules (BAM) - Erosion, implements previously published erosion analysis techniques as modules in 3D Slicer, an open-source image processing and visualization tool. BAM includes a module to automatically identify cortical interruptions, from which erosions are manually selected, and a hybrid module that combines morphological and level set operations to quantify the volume of bone erosions. HR-pQCT images of the second and third metacarpophalangeal (MCP) joints were acquired in patients with RA (XtremeCT, n = 14, XtremeCTII, n = 22). The number of cortical interruptions detected by BAM-Erosion agreed strongly with the previously published cortical interruption detection algorithm for both XtremeCT (r2 = 0.85) and XtremeCTII (r2 = 0.87). Erosion volume assessment by BAM-Erosion agreed strongly (r2 = 0.95) with the Medical Image Analysis Framework. BAM-Erosion provides an open-source erosion analysis tool that produces comparable results to previously published algorithms, with improved options for visualization. The strength of the tool is that it implements multiple image processing algorithms for erosion analysis on a single, widely available, open-source platform that can accommodate future updates.\",\"PeriodicalId\":93913,\"journal\":{\"name\":\"Bone\",\"volume\":\"1 1\",\"pages\":\"116571\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bone\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.2139/ssrn.4169782\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.2139/ssrn.4169782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

骨糜烂的识别和糜烂体积的量化对类风湿关节炎的诊断是重要的,并且可以为评估疾病进展和治疗效果提供重要信息。高分辨率外围定量计算机断层扫描(HR-pQCT)非常适合这一目的,然而分析方法并不广泛可用。本研究的目的是开发一种开源软件工具,用于利用HR-pQCT获得的图像识别和定量骨侵蚀。骨骼分析模块(BAM) -侵蚀模块的集合实现了先前发布的侵蚀分析技术,作为3D切片器的模块,这是一个开源的图像处理和可视化工具。BAM包括一个自动识别皮质中断的模块,从中手动选择侵蚀,以及一个结合形态学和水平集操作的混合模块,以量化骨侵蚀的体积。获得RA患者第二和第三掌指(MCP)关节的HR-pQCT图像(XtremeCT, n = 14,XtremeCTII, n = 22)。BAM-Erosion检测到的皮质中断数量与之前发表的XtremeCT (r2 = 0.85)和XtremeCTII (r2 = 0.87)的皮质中断检测算法非常吻合。BAM-Erosion的侵蚀体积评估与医学图像分析框架非常一致(r2 = 0.95)。BAM-Erosion提供了一个开源的侵蚀分析工具,可以产生与以前发布的算法相当的结果,并改进了可视化选项。该工具的优势在于,它在一个广泛可用的开源平台上实现了用于侵蚀分析的多种图像处理算法,该平台可以适应未来的更新。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Open-source image analysis tool for the identification and quantification of cortical interruptions and bone erosions in high-resolution peripheral quantitative computed tomography images of patients with rheumatoid arthritis.
Identification of bone erosions and quantification of erosion volume is important for rheumatoid arthritis diagnosis, and can add important information to evaluate disease progression and treatment effects. High-resolution peripheral quantitative computed tomography (HR-pQCT) is well suited for this purpose, however analysis methods are not widely available. The purpose of this study was to develop an open-source software tool for the identification and quantification of bone erosions using images acquired by HR-pQCT. The collection of modules, Bone Analysis Modules (BAM) - Erosion, implements previously published erosion analysis techniques as modules in 3D Slicer, an open-source image processing and visualization tool. BAM includes a module to automatically identify cortical interruptions, from which erosions are manually selected, and a hybrid module that combines morphological and level set operations to quantify the volume of bone erosions. HR-pQCT images of the second and third metacarpophalangeal (MCP) joints were acquired in patients with RA (XtremeCT, n = 14, XtremeCTII, n = 22). The number of cortical interruptions detected by BAM-Erosion agreed strongly with the previously published cortical interruption detection algorithm for both XtremeCT (r2 = 0.85) and XtremeCTII (r2 = 0.87). Erosion volume assessment by BAM-Erosion agreed strongly (r2 = 0.95) with the Medical Image Analysis Framework. BAM-Erosion provides an open-source erosion analysis tool that produces comparable results to previously published algorithms, with improved options for visualization. The strength of the tool is that it implements multiple image processing algorithms for erosion analysis on a single, widely available, open-source platform that can accommodate future updates.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信