TAVI中的阶级效应:现在是时候知道它们是否都一样了

Q2 Medicine
Cristóbal A. Urbano-Carrillo
{"title":"TAVI中的阶级效应:现在是时候知道它们是否都一样了","authors":"Cristóbal A. Urbano-Carrillo","doi":"10.24875/recice.m22000358","DOIUrl":null,"url":null,"abstract":"Introduction and objectives: Advances made in transcatheter aortic valve implantation (TAVI) valvular technology have resulted in better outcomes and fewer complications compared with older generations. We studied the rate and determinants of paravalvular leak (PVL) using Evolut PRO vs SAPIEN 3 valves as well as other perioperative and in-hospital outcomes. Methods: A total of 110 consecutive patients with severe aortic stenosis scheduled for transfemoral TAVI were randomly selected to receive the SAPIEN 3 (N = 59) or the Evolut PRO valve (N = 51). Annular dimensions were determined by transesophageal echocardiography guided balloon sizing. The following postoperative and in-hospital endpoints were assessed: PVL, conduction defects, valve embolization, need for a second valve, annular rupture, stroke, vascular complications, acute kidney injury, and in-hospital mortality. We also studied the possible anatomical determinants of PVL. Results: There were no relevant baseline differences between the 2 groups regarding clinical and echocardiographic characteristics. In-hospital complications were comparable between both valves apart from a significantly higher rate of immediate postoperative PVL and at discharge (≥ grade II) between the Evolut PRO and the SAPIEN 3 valves (19.6% vs 6.8%) and (5.9% vs 1.7%), respectively. Of the anatomical variables described, the left ventricular outflow tract/ascending aorta angle, aortic angulation, and calcification had a significant impact on PVL in the Evolut PRO valves. The left ventricular outflow tract/ascending aorta angle revealed a negative correlation with implantation depth in the Evolut PRO valves but not in the SAPIEN 3 ones. Conclusions: Both valves demonstrated favorable comparable outcomes except for a significantly higher rate of PVL in patients implanted with Evolut PRO valves. REC Interv Cardiol. 2023;5(2):94-101 https://doi.org/10.24875/RECICE.M22000351","PeriodicalId":34613,"journal":{"name":"REC Interventional Cardiology English Ed","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Class effect in TAVI: the time has come to know if they are all the same\",\"authors\":\"Cristóbal A. Urbano-Carrillo\",\"doi\":\"10.24875/recice.m22000358\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction and objectives: Advances made in transcatheter aortic valve implantation (TAVI) valvular technology have resulted in better outcomes and fewer complications compared with older generations. We studied the rate and determinants of paravalvular leak (PVL) using Evolut PRO vs SAPIEN 3 valves as well as other perioperative and in-hospital outcomes. Methods: A total of 110 consecutive patients with severe aortic stenosis scheduled for transfemoral TAVI were randomly selected to receive the SAPIEN 3 (N = 59) or the Evolut PRO valve (N = 51). Annular dimensions were determined by transesophageal echocardiography guided balloon sizing. The following postoperative and in-hospital endpoints were assessed: PVL, conduction defects, valve embolization, need for a second valve, annular rupture, stroke, vascular complications, acute kidney injury, and in-hospital mortality. We also studied the possible anatomical determinants of PVL. Results: There were no relevant baseline differences between the 2 groups regarding clinical and echocardiographic characteristics. In-hospital complications were comparable between both valves apart from a significantly higher rate of immediate postoperative PVL and at discharge (≥ grade II) between the Evolut PRO and the SAPIEN 3 valves (19.6% vs 6.8%) and (5.9% vs 1.7%), respectively. Of the anatomical variables described, the left ventricular outflow tract/ascending aorta angle, aortic angulation, and calcification had a significant impact on PVL in the Evolut PRO valves. The left ventricular outflow tract/ascending aorta angle revealed a negative correlation with implantation depth in the Evolut PRO valves but not in the SAPIEN 3 ones. Conclusions: Both valves demonstrated favorable comparable outcomes except for a significantly higher rate of PVL in patients implanted with Evolut PRO valves. REC Interv Cardiol. 2023;5(2):94-101 https://doi.org/10.24875/RECICE.M22000351\",\"PeriodicalId\":34613,\"journal\":{\"name\":\"REC Interventional Cardiology English Ed\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"REC Interventional Cardiology English Ed\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24875/recice.m22000358\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"REC Interventional Cardiology English Ed","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24875/recice.m22000358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

引言和目的:与老一辈相比,经导管主动脉瓣植入术(TAVI)瓣膜技术的进步带来了更好的结果和更少的并发症。我们使用Evolut PRO与SAPIEN 3瓣膜研究了瓣膜周渗漏(PVL)的发生率和决定因素,以及其他围手术期和住院结果。方法:随机选择110名连续的严重主动脉瓣狭窄患者接受经股TAVI治疗,接受SAPIEN3(N=59)或Evolut PRO瓣膜(N=51)。通过经食道超声心动图引导球囊大小测定环形尺寸。评估了以下术后和住院终点:PVL、传导缺陷、瓣膜栓塞、是否需要第二个瓣膜、瓣环破裂、中风、血管并发症、急性肾损伤和住院死亡率。我们还研究了PVL可能的解剖学决定因素。结果:两组在临床和超声心动图特征方面没有相关的基线差异。除了Evolut PRO和SAPIEN 3瓣膜术后即刻PVL和出院时(≥II级)的发生率显著较高(分别为19.6%vs 6.8%)和(5.9%vs 1.7%)外,两种瓣膜的住院并发症具有可比性。在所描述的解剖变量中,左心室流出道/升主动脉角度、主动脉成角和钙化对Evolut PRO瓣膜的PVL有显著影响。左心室流出道/升主动脉角与Evolut PRO瓣膜的植入深度呈负相关,但与SAPIEN 3瓣膜的植入厚度无关。结论:除了Evolut PRO瓣膜植入患者的PVL发生率明显较高外,两种瓣膜均显示出良好的可比结果。REC介入心脏病学。2023年;5(2):94-101https://doi.org/10.24875/RECICE.M22000351
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Class effect in TAVI: the time has come to know if they are all the same
Introduction and objectives: Advances made in transcatheter aortic valve implantation (TAVI) valvular technology have resulted in better outcomes and fewer complications compared with older generations. We studied the rate and determinants of paravalvular leak (PVL) using Evolut PRO vs SAPIEN 3 valves as well as other perioperative and in-hospital outcomes. Methods: A total of 110 consecutive patients with severe aortic stenosis scheduled for transfemoral TAVI were randomly selected to receive the SAPIEN 3 (N = 59) or the Evolut PRO valve (N = 51). Annular dimensions were determined by transesophageal echocardiography guided balloon sizing. The following postoperative and in-hospital endpoints were assessed: PVL, conduction defects, valve embolization, need for a second valve, annular rupture, stroke, vascular complications, acute kidney injury, and in-hospital mortality. We also studied the possible anatomical determinants of PVL. Results: There were no relevant baseline differences between the 2 groups regarding clinical and echocardiographic characteristics. In-hospital complications were comparable between both valves apart from a significantly higher rate of immediate postoperative PVL and at discharge (≥ grade II) between the Evolut PRO and the SAPIEN 3 valves (19.6% vs 6.8%) and (5.9% vs 1.7%), respectively. Of the anatomical variables described, the left ventricular outflow tract/ascending aorta angle, aortic angulation, and calcification had a significant impact on PVL in the Evolut PRO valves. The left ventricular outflow tract/ascending aorta angle revealed a negative correlation with implantation depth in the Evolut PRO valves but not in the SAPIEN 3 ones. Conclusions: Both valves demonstrated favorable comparable outcomes except for a significantly higher rate of PVL in patients implanted with Evolut PRO valves. REC Interv Cardiol. 2023;5(2):94-101 https://doi.org/10.24875/RECICE.M22000351
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
REC Interventional Cardiology English Ed
REC Interventional Cardiology English Ed Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.70
自引率
0.00%
发文量
86
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信