{"title":"急诊收治的四肢创伤患者的常规x线摄影与计算机断层摄影的比较——一项回顾性研究","authors":"Burak Üstün, M. Korkut, S. Söyüncü","doi":"10.5603/demj.a2023.0016","DOIUrl":null,"url":null,"abstract":"INTRODUCTION: This study aims to compare conventional radiography (X-ray) and computed tomography (CT) on diagnosis, operation plan, and hospitalization of patients with isolated extremity trauma admitted to the emergency department (ED). MATERIAL AND METHODS: This study was designed retrospectively. Patients with trauma involving extremities presenting to a tertiary ED between January 2019 and 2020 for twelve months who underwent both extremity CT and X-ray imaging were included in the study. The sensitivity, specificity, PPV, NPV, and Kappa coefficients were calculated on the CT reports. RESULTS: A total of 1306 patients were included in the study. Extremity fractures were detected in 620 (47.6%) and 775 (59.3%) patients evaluated with X-ray, and CT scans respectively. The diagnostic accuracy of the X-ray of all extremity fractures by anatomical region was evaluated. For the shoulder region compared with CT, X-ray had a sensitivity of 95%, specificity of 98%, PPV 98%, and NPV 96% [AUC: 0.969, 95% CI 0.935 to 1.000) in","PeriodicalId":52339,"journal":{"name":"Disaster and Emergency Medicine Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of conventional radiography and computed tomography in patients admitted to the emergency department with extremity trauma — a retrospective study\",\"authors\":\"Burak Üstün, M. Korkut, S. Söyüncü\",\"doi\":\"10.5603/demj.a2023.0016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"INTRODUCTION: This study aims to compare conventional radiography (X-ray) and computed tomography (CT) on diagnosis, operation plan, and hospitalization of patients with isolated extremity trauma admitted to the emergency department (ED). MATERIAL AND METHODS: This study was designed retrospectively. Patients with trauma involving extremities presenting to a tertiary ED between January 2019 and 2020 for twelve months who underwent both extremity CT and X-ray imaging were included in the study. The sensitivity, specificity, PPV, NPV, and Kappa coefficients were calculated on the CT reports. RESULTS: A total of 1306 patients were included in the study. Extremity fractures were detected in 620 (47.6%) and 775 (59.3%) patients evaluated with X-ray, and CT scans respectively. The diagnostic accuracy of the X-ray of all extremity fractures by anatomical region was evaluated. For the shoulder region compared with CT, X-ray had a sensitivity of 95%, specificity of 98%, PPV 98%, and NPV 96% [AUC: 0.969, 95% CI 0.935 to 1.000) in\",\"PeriodicalId\":52339,\"journal\":{\"name\":\"Disaster and Emergency Medicine Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Disaster and Emergency Medicine Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5603/demj.a2023.0016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Disaster and Emergency Medicine Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5603/demj.a2023.0016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
Comparison of conventional radiography and computed tomography in patients admitted to the emergency department with extremity trauma — a retrospective study
INTRODUCTION: This study aims to compare conventional radiography (X-ray) and computed tomography (CT) on diagnosis, operation plan, and hospitalization of patients with isolated extremity trauma admitted to the emergency department (ED). MATERIAL AND METHODS: This study was designed retrospectively. Patients with trauma involving extremities presenting to a tertiary ED between January 2019 and 2020 for twelve months who underwent both extremity CT and X-ray imaging were included in the study. The sensitivity, specificity, PPV, NPV, and Kappa coefficients were calculated on the CT reports. RESULTS: A total of 1306 patients were included in the study. Extremity fractures were detected in 620 (47.6%) and 775 (59.3%) patients evaluated with X-ray, and CT scans respectively. The diagnostic accuracy of the X-ray of all extremity fractures by anatomical region was evaluated. For the shoulder region compared with CT, X-ray had a sensitivity of 95%, specificity of 98%, PPV 98%, and NPV 96% [AUC: 0.969, 95% CI 0.935 to 1.000) in