Henrikh H. Herasymov, Ievgenii Gerasimov, S. Ivanov, Oleg Pinchuk
{"title":"端闸阀组合关闭效果的实验研究","authors":"Henrikh H. Herasymov, Ievgenii Gerasimov, S. Ivanov, Oleg Pinchuk","doi":"10.1515/heem-2019-0001","DOIUrl":null,"url":null,"abstract":"Abstract One of the ways to ensure a reliable operation of irrigation systems is to protect them from water hammer (hydraulic shock) damage that occurs when starting or stopping a pumping station. This can be achieved by creating conditions in which a water hammer will not occur in the pressure pipeline as a result of closing the end gate valve (EGV). The aim of the present study was to investigate processes occurring in the pipeline during a linear closure of the EGV, during a closure with one break point and during an intermittent closure, as well as to verify the effectiveness of a combined end gate valve closure of the pipeline. Based on experimental data and calculations, the article recommends a linear closure of the EGV with one break point.","PeriodicalId":53658,"journal":{"name":"Archives of Hydroengineering and Environmental Mechanics","volume":"66 1","pages":"13 - 3"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental Study of the Effectiveness of a Combined Closure of the End Gate Pipeline Valve\",\"authors\":\"Henrikh H. Herasymov, Ievgenii Gerasimov, S. Ivanov, Oleg Pinchuk\",\"doi\":\"10.1515/heem-2019-0001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract One of the ways to ensure a reliable operation of irrigation systems is to protect them from water hammer (hydraulic shock) damage that occurs when starting or stopping a pumping station. This can be achieved by creating conditions in which a water hammer will not occur in the pressure pipeline as a result of closing the end gate valve (EGV). The aim of the present study was to investigate processes occurring in the pipeline during a linear closure of the EGV, during a closure with one break point and during an intermittent closure, as well as to verify the effectiveness of a combined end gate valve closure of the pipeline. Based on experimental data and calculations, the article recommends a linear closure of the EGV with one break point.\",\"PeriodicalId\":53658,\"journal\":{\"name\":\"Archives of Hydroengineering and Environmental Mechanics\",\"volume\":\"66 1\",\"pages\":\"13 - 3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Hydroengineering and Environmental Mechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/heem-2019-0001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Hydroengineering and Environmental Mechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/heem-2019-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Environmental Science","Score":null,"Total":0}
Experimental Study of the Effectiveness of a Combined Closure of the End Gate Pipeline Valve
Abstract One of the ways to ensure a reliable operation of irrigation systems is to protect them from water hammer (hydraulic shock) damage that occurs when starting or stopping a pumping station. This can be achieved by creating conditions in which a water hammer will not occur in the pressure pipeline as a result of closing the end gate valve (EGV). The aim of the present study was to investigate processes occurring in the pipeline during a linear closure of the EGV, during a closure with one break point and during an intermittent closure, as well as to verify the effectiveness of a combined end gate valve closure of the pipeline. Based on experimental data and calculations, the article recommends a linear closure of the EGV with one break point.
期刊介绍:
Archives of Hydro-Engineering and Environmental Mechanics cover the broad area of disciplines related to hydro-engineering, including: hydrodynamics and hydraulics of inlands and sea waters, hydrology, hydroelasticity, ground-water hydraulics, water contamination, coastal engineering, geotechnical engineering, geomechanics, structural mechanics, etc. The main objective of Archives of Hydro-Engineering and Environmental Mechanics is to provide an up-to-date reference to the engineers and scientists engaged in the applications of mechanics to the analysis of various phenomena appearing in the natural environment.