Fe-Ni@ACC纳米复合材料磁分散微固相萃取食品和头发样品中的Cu (II)

IF 3.4 2区 化学 Q1 SPECTROSCOPY
M. Soylak
{"title":"Fe-Ni@ACC纳米复合材料磁分散微固相萃取食品和头发样品中的Cu (II)","authors":"M. Soylak","doi":"10.46770/as.2023.086","DOIUrl":null,"url":null,"abstract":": Fe-Ni@ACC nanocomposite was synthesized by hydrothermal method and characterized using scanning electron microscope (SEM) and Fourier-transform infrared spectroscopy (FT-IR). Fe-Ni@ACC was used as adsorbent for magnetic dispersive micro solid-phase extraction (M-D-μSPE) procedure for separation and preconcentration of trace level of copper at trace levels before its determination by microsampling flame atomic absorption spectrometry (FAAS). The effects of various parameters such as pH, amount of adsorbent, eluent type and eluent volume, and sample volume on the recoveries of copper on Fe-Ni@ACC were optimized. The presented method is accurate, inexpensive and environmentally friendly and due to magnetic properties of the adsorbent, the separation process is very simple and fast. The method presents limit of detection (LOD)(3s/m) of 0.69 μg L −1 , limit of quantification (LOQ)(10s/m) of 2.29 μg L −1 , preconcentration factor of 40 and relative standard deviation (RSD %) (s/x) 1.18%. The accuracy of the method was confirmed by the analysis of TMDA-53.3 fortified water and TMDA-64.2 fortified water certified reference materials and addition-recovery tests to real samples. The present M-D-μSPE method was successfully applied to determination of copper level of tap water, cigarette, human hairs and black teas samples.","PeriodicalId":8642,"journal":{"name":"Atomic Spectroscopy","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2023-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fe-Ni@ACC Nanocomposite For Magnetic Dispersive Micro Solid-Phase Extraction Of Cu (II) From Food And Hair Samples\",\"authors\":\"M. Soylak\",\"doi\":\"10.46770/as.2023.086\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": Fe-Ni@ACC nanocomposite was synthesized by hydrothermal method and characterized using scanning electron microscope (SEM) and Fourier-transform infrared spectroscopy (FT-IR). Fe-Ni@ACC was used as adsorbent for magnetic dispersive micro solid-phase extraction (M-D-μSPE) procedure for separation and preconcentration of trace level of copper at trace levels before its determination by microsampling flame atomic absorption spectrometry (FAAS). The effects of various parameters such as pH, amount of adsorbent, eluent type and eluent volume, and sample volume on the recoveries of copper on Fe-Ni@ACC were optimized. The presented method is accurate, inexpensive and environmentally friendly and due to magnetic properties of the adsorbent, the separation process is very simple and fast. The method presents limit of detection (LOD)(3s/m) of 0.69 μg L −1 , limit of quantification (LOQ)(10s/m) of 2.29 μg L −1 , preconcentration factor of 40 and relative standard deviation (RSD %) (s/x) 1.18%. The accuracy of the method was confirmed by the analysis of TMDA-53.3 fortified water and TMDA-64.2 fortified water certified reference materials and addition-recovery tests to real samples. The present M-D-μSPE method was successfully applied to determination of copper level of tap water, cigarette, human hairs and black teas samples.\",\"PeriodicalId\":8642,\"journal\":{\"name\":\"Atomic Spectroscopy\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2023-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atomic Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.46770/as.2023.086\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.46770/as.2023.086","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

摘要

: Fe-Ni@ACC采用水热法制备了纳米复合材料,并利用扫描电镜(SEM)和傅里叶变换红外光谱(FT-IR)对其进行了表征。以Fe-Ni@ACC为吸附剂,采用磁分散微固相萃取(M-D-μSPE)工艺对痕量铜进行分离和预富集,然后采用微进样火焰原子吸收光谱法(FAAS)测定痕量铜。考察了pH、吸附剂用量、洗脱液种类、洗脱液体积、样品体积等参数对Fe-Ni@ACC上铜回收率的影响。该方法准确、廉价、环保,并且由于吸附剂的磁性,分离过程简单、快速。方法检出限(LOD)为0.69 μg L−1,定量限(LOQ)为2.29 μg L−1,富集系数为40,相对标准偏差(RSD %)为1.18% (s/x)。通过对TMDA-53.3强化水和TMDA-64.2强化水标准物质的分析和对实际样品的添加回收率试验,验证了该方法的准确性。M-D-μ固相萃取法成功地应用于自来水、香烟、人发和红茶样品中铜的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fe-Ni@ACC Nanocomposite For Magnetic Dispersive Micro Solid-Phase Extraction Of Cu (II) From Food And Hair Samples
: Fe-Ni@ACC nanocomposite was synthesized by hydrothermal method and characterized using scanning electron microscope (SEM) and Fourier-transform infrared spectroscopy (FT-IR). Fe-Ni@ACC was used as adsorbent for magnetic dispersive micro solid-phase extraction (M-D-μSPE) procedure for separation and preconcentration of trace level of copper at trace levels before its determination by microsampling flame atomic absorption spectrometry (FAAS). The effects of various parameters such as pH, amount of adsorbent, eluent type and eluent volume, and sample volume on the recoveries of copper on Fe-Ni@ACC were optimized. The presented method is accurate, inexpensive and environmentally friendly and due to magnetic properties of the adsorbent, the separation process is very simple and fast. The method presents limit of detection (LOD)(3s/m) of 0.69 μg L −1 , limit of quantification (LOQ)(10s/m) of 2.29 μg L −1 , preconcentration factor of 40 and relative standard deviation (RSD %) (s/x) 1.18%. The accuracy of the method was confirmed by the analysis of TMDA-53.3 fortified water and TMDA-64.2 fortified water certified reference materials and addition-recovery tests to real samples. The present M-D-μSPE method was successfully applied to determination of copper level of tap water, cigarette, human hairs and black teas samples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atomic Spectroscopy
Atomic Spectroscopy 物理-光谱学
CiteScore
5.30
自引率
14.70%
发文量
42
审稿时长
4.5 months
期刊介绍: The ATOMIC SPECTROSCOPY is a peer-reviewed international journal started in 1962 by Dr. Walter Slavin and now is published by Atomic Spectroscopy Press Limited (ASPL). It is intended for the rapid publication of both original articles and review articles in the fields of AAS, AFS, ICP-OES, ICP-MS, GD-MS, TIMS, SIMS, AMS, LIBS, XRF and related techniques. Manuscripts dealing with (i) instrumentation & fundamentals, (ii) methodology development & applications, and (iii) standard reference materials (SRMs) development can be submitted for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信