体外冲击波碎石术前带槽输尿管支架与光滑输尿管支架的比较:单盲随机临床试验

IF 1.3 Q3 UROLOGY & NEPHROLOGY
Abdulqadir Alobaidy, T. Ibrahim, W. El Ansari, H. Tawfik, A. Al-Naimi, S. Hussain, A. Al-Ansari
{"title":"体外冲击波碎石术前带槽输尿管支架与光滑输尿管支架的比较:单盲随机临床试验","authors":"Abdulqadir Alobaidy, T. Ibrahim, W. El Ansari, H. Tawfik, A. Al-Naimi, S. Hussain, A. Al-Ansari","doi":"10.1080/2090598X.2021.2004502","DOIUrl":null,"url":null,"abstract":"ABSTRACT Objective No study compared the grooved stent to the widely used standard smooth (non-grooved) stent in humans. We compared stone clearance, complications, and patient tolerance of the grooved stent vs standard JJ stent. Patients and Methods Single-blinded randomised trial among patients planned for pre-extracorporeal shockwave lithotripsy (ESWL) stenting. Adult patients with unilateral ureteric/renal stones planned for ESWL were randomly assigned to receive (Percuflex) smooth ureteric stent or (Visiostar) grooved lithotripsy stent and blinded to the stent type. We collected and compared the baseline data and outcomes (stone-free rate, complications, and stent-related symptoms) of both patient groups. Results A total of 96 adults were included (48 per arm). There were no significant differences between the groups at baseline in terms of demographics, body mass index, comorbidities, renal function, number of ESWL sessions, and stone characteristics, including pre-ESWL stone volume (mean [SD] smooth 310.2 [301.6] vs grooved 270.7 [278.6] mm3, P = 0.5). Stone clearance was statistically insignificant between the groups, although clinically relevant (smooth stent 70.8% vs grooved stent 81.2%, P = 0.2). Grooved-stent patients reported comparable urinary symptoms score (P = 0.05) and operative complications (P = 0.6), but significantly more urinary tract infections (UTIs) not requiring hospitalisation (P = 0.003). Conclusions Although statistically insignificant, the grooved stent exhibited higher stone clearance compared to the smooth stent, with similar complication rates excpet that patients with grooved stents reported more UTIs. A re-visit to the size of the outer diameter of the grooved stent could enhance its stone clearance properties, and further development of its coating material could lead to better patient satisfaction.","PeriodicalId":8113,"journal":{"name":"Arab Journal of Urology","volume":"20 1","pages":"41 - 48"},"PeriodicalIF":1.3000,"publicationDate":"2021-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Grooved vs smooth ureteric stent before extracorporeal shockwave lithotripsy: Single-blind randomised clinical trial\",\"authors\":\"Abdulqadir Alobaidy, T. Ibrahim, W. El Ansari, H. Tawfik, A. Al-Naimi, S. Hussain, A. Al-Ansari\",\"doi\":\"10.1080/2090598X.2021.2004502\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Objective No study compared the grooved stent to the widely used standard smooth (non-grooved) stent in humans. We compared stone clearance, complications, and patient tolerance of the grooved stent vs standard JJ stent. Patients and Methods Single-blinded randomised trial among patients planned for pre-extracorporeal shockwave lithotripsy (ESWL) stenting. Adult patients with unilateral ureteric/renal stones planned for ESWL were randomly assigned to receive (Percuflex) smooth ureteric stent or (Visiostar) grooved lithotripsy stent and blinded to the stent type. We collected and compared the baseline data and outcomes (stone-free rate, complications, and stent-related symptoms) of both patient groups. Results A total of 96 adults were included (48 per arm). There were no significant differences between the groups at baseline in terms of demographics, body mass index, comorbidities, renal function, number of ESWL sessions, and stone characteristics, including pre-ESWL stone volume (mean [SD] smooth 310.2 [301.6] vs grooved 270.7 [278.6] mm3, P = 0.5). Stone clearance was statistically insignificant between the groups, although clinically relevant (smooth stent 70.8% vs grooved stent 81.2%, P = 0.2). Grooved-stent patients reported comparable urinary symptoms score (P = 0.05) and operative complications (P = 0.6), but significantly more urinary tract infections (UTIs) not requiring hospitalisation (P = 0.003). Conclusions Although statistically insignificant, the grooved stent exhibited higher stone clearance compared to the smooth stent, with similar complication rates excpet that patients with grooved stents reported more UTIs. A re-visit to the size of the outer diameter of the grooved stent could enhance its stone clearance properties, and further development of its coating material could lead to better patient satisfaction.\",\"PeriodicalId\":8113,\"journal\":{\"name\":\"Arab Journal of Urology\",\"volume\":\"20 1\",\"pages\":\"41 - 48\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2021-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arab Journal of Urology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/2090598X.2021.2004502\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arab Journal of Urology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/2090598X.2021.2004502","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

【摘要】目的没有研究将沟槽支架与广泛使用的标准光滑(非沟槽)支架进行比较。我们比较了沟槽支架与标准JJ支架的结石清除、并发症和患者耐受性。患者和方法在计划进行体外冲击波碎石(ESWL)支架置入术的患者中进行单盲随机试验。计划行ESWL的单侧输尿管/肾结石成年患者被随机分配接受(Percuflex)光滑输尿管支架或(Visiostar)沟槽碎石支架,并对支架类型进行盲测。我们收集并比较了两组患者的基线数据和结果(无结石率、并发症和支架相关症状)。结果共纳入96例成人(每组48例)。在基线时,两组在人口统计学、体重指数、合并症、肾功能、ESWL次数和结石特征(包括ESWL前结石体积)方面无显著差异(平均[SD]平滑310.2 [301.6]vs沟槽270.7 [278.6]mm3, P = 0.5)。尽管具有临床相关性(光滑支架70.8% vs沟槽支架81.2%,P = 0.2),但两组间结石清除率差异无统计学意义。槽状支架患者报告的泌尿系统症状评分(P = 0.05)和手术并发症(P = 0.6)相当,但明显更多的尿路感染(uti)不需要住院(P = 0.003)。结论:虽然没有统计学意义,但与光滑支架相比,沟槽支架的结石清除率更高,并发症发生率相似,但沟槽支架患者报告的尿路感染更多。重新检查沟槽支架外径的大小可以提高其清除结石的性能,进一步开发其涂层材料可以提高患者的满意度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Grooved vs smooth ureteric stent before extracorporeal shockwave lithotripsy: Single-blind randomised clinical trial
ABSTRACT Objective No study compared the grooved stent to the widely used standard smooth (non-grooved) stent in humans. We compared stone clearance, complications, and patient tolerance of the grooved stent vs standard JJ stent. Patients and Methods Single-blinded randomised trial among patients planned for pre-extracorporeal shockwave lithotripsy (ESWL) stenting. Adult patients with unilateral ureteric/renal stones planned for ESWL were randomly assigned to receive (Percuflex) smooth ureteric stent or (Visiostar) grooved lithotripsy stent and blinded to the stent type. We collected and compared the baseline data and outcomes (stone-free rate, complications, and stent-related symptoms) of both patient groups. Results A total of 96 adults were included (48 per arm). There were no significant differences between the groups at baseline in terms of demographics, body mass index, comorbidities, renal function, number of ESWL sessions, and stone characteristics, including pre-ESWL stone volume (mean [SD] smooth 310.2 [301.6] vs grooved 270.7 [278.6] mm3, P = 0.5). Stone clearance was statistically insignificant between the groups, although clinically relevant (smooth stent 70.8% vs grooved stent 81.2%, P = 0.2). Grooved-stent patients reported comparable urinary symptoms score (P = 0.05) and operative complications (P = 0.6), but significantly more urinary tract infections (UTIs) not requiring hospitalisation (P = 0.003). Conclusions Although statistically insignificant, the grooved stent exhibited higher stone clearance compared to the smooth stent, with similar complication rates excpet that patients with grooved stents reported more UTIs. A re-visit to the size of the outer diameter of the grooved stent could enhance its stone clearance properties, and further development of its coating material could lead to better patient satisfaction.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arab Journal of Urology
Arab Journal of Urology UROLOGY & NEPHROLOGY-
CiteScore
2.80
自引率
0.00%
发文量
40
期刊介绍: The Arab Journal of Urology is a peer-reviewed journal that strives to provide a high standard of research and clinical material to the widest possible urological community worldwide. The journal encompasses all aspects of urology including: urological oncology, urological reconstructive surgery, urodynamics, female urology, pediatric urology, endourology, transplantation, erectile dysfunction, and urinary infections and inflammations. The journal provides reviews, original articles, editorials, surgical techniques, cases reports and correspondence. Urologists, oncologists, pathologists, radiologists and scientists are invited to submit their contributions to make the Arab Journal of Urology a viable international forum for the practical, timely and state-of-the-art clinical urology and basic urological research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信