与新型耐磨牙科植入物表面:Bioloy®涂层接触的细胞和组织的组织形态学评估

Q4 Medicine
E. Canciani, E. Galliera, M. Marazzi, Mondella Gianluca, Karang Daniel, Graziano Daniele, A. Oliveira, C. Dellavia
{"title":"与新型耐磨牙科植入物表面:Bioloy®涂层接触的细胞和组织的组织形态学评估","authors":"E. Canciani, E. Galliera, M. Marazzi, Mondella Gianluca, Karang Daniel, Graziano Daniele, A. Oliveira, C. Dellavia","doi":"10.13128/IJAE-21437","DOIUrl":null,"url":null,"abstract":"Dental implants rehabilitation of edentulous patients is the current accepted treatment to increase prosthetic stabilization. Various implant surface modifications have been tried to enhance osseointegration and to reduce the spread of detrimental metallic ions toward host tissues [1]. The aim of this preliminary study was to investigate in vitro the viability, proliferation and adhesion of a Bioloy® (B®) coating compared to machined and sandblasted surfaces and to assess histologically in vivo the bone response to customized mini-implants coated with B® () placed in the mandible of patients. B® is a titanium niobium nitride coating applied on surface by physical vapor deposition (Permedica Spa). It is a thin ceramic monolayer, extremely hard and with high resistance against wear, scratches and corrosion [2] Viability and adhesion was tested at 24, 48 and 72 hours after seeding of SAOS-2 on customised scaffold. Cell viability (2x104 cells) was evaluated by AlamarBlue® assay [3] and it resulted statistically higher on B® than in the other 2 groups (48 and 72 hours, p-value<0.05). No toxic response was observed. Adhesion (104 cells) was analysed by scanning electron microscope [3]. Cell morphology confirmed the healthy status. Cells adhered to the surface and proliferated, covering completely the surfaces of machined and B® at 72 hours. Osseointegration was evaluated in 2 patients. After tooth extraction, 3 MIB® were placed. Three months later, during drilling process, the biopsies with MIB® were harvested for histological processing (Donath’ protocol) [3]. In all sections MIB® resulted well osseointegrated and newly formed bone was highly mineralized and organized in lamellae (bone to implant contact 46.8%±9.15). The implant coils were filled with new bone for the 59.8% ± 4.23. Medullary spaces were rich in blood vessels without inflammatory infiltrate. In conclusion, B® is a promising coating able to enhance the viability in vitro and to favor the osseointegration in vivo.","PeriodicalId":14636,"journal":{"name":"Italian journal of anatomy and embryology","volume":"122 1","pages":"45-45"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.13128/IJAE-21437","citationCount":"0","resultStr":"{\"title\":\"Histomorphometrical evaluation of cells and tissues in contact with a new anti-wear dental implant surface: Bioloy® coating\",\"authors\":\"E. Canciani, E. Galliera, M. Marazzi, Mondella Gianluca, Karang Daniel, Graziano Daniele, A. Oliveira, C. Dellavia\",\"doi\":\"10.13128/IJAE-21437\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Dental implants rehabilitation of edentulous patients is the current accepted treatment to increase prosthetic stabilization. Various implant surface modifications have been tried to enhance osseointegration and to reduce the spread of detrimental metallic ions toward host tissues [1]. The aim of this preliminary study was to investigate in vitro the viability, proliferation and adhesion of a Bioloy® (B®) coating compared to machined and sandblasted surfaces and to assess histologically in vivo the bone response to customized mini-implants coated with B® () placed in the mandible of patients. B® is a titanium niobium nitride coating applied on surface by physical vapor deposition (Permedica Spa). It is a thin ceramic monolayer, extremely hard and with high resistance against wear, scratches and corrosion [2] Viability and adhesion was tested at 24, 48 and 72 hours after seeding of SAOS-2 on customised scaffold. Cell viability (2x104 cells) was evaluated by AlamarBlue® assay [3] and it resulted statistically higher on B® than in the other 2 groups (48 and 72 hours, p-value<0.05). No toxic response was observed. Adhesion (104 cells) was analysed by scanning electron microscope [3]. Cell morphology confirmed the healthy status. Cells adhered to the surface and proliferated, covering completely the surfaces of machined and B® at 72 hours. Osseointegration was evaluated in 2 patients. After tooth extraction, 3 MIB® were placed. Three months later, during drilling process, the biopsies with MIB® were harvested for histological processing (Donath’ protocol) [3]. In all sections MIB® resulted well osseointegrated and newly formed bone was highly mineralized and organized in lamellae (bone to implant contact 46.8%±9.15). The implant coils were filled with new bone for the 59.8% ± 4.23. Medullary spaces were rich in blood vessels without inflammatory infiltrate. In conclusion, B® is a promising coating able to enhance the viability in vitro and to favor the osseointegration in vivo.\",\"PeriodicalId\":14636,\"journal\":{\"name\":\"Italian journal of anatomy and embryology\",\"volume\":\"122 1\",\"pages\":\"45-45\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.13128/IJAE-21437\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Italian journal of anatomy and embryology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13128/IJAE-21437\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Italian journal of anatomy and embryology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13128/IJAE-21437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

无牙患者的种植牙康复是目前公认的提高假体稳定性的治疗方法。已经尝试了各种植入物表面修饰来增强骨整合并减少有害金属离子向宿主组织的扩散[1]。本初步研究的目的是在体外研究Bioloy®(B®)涂层与机械加工和喷砂表面相比的生存能力、增殖和粘附性,并在体内组织学上评估对患者下颌骨中植入的涂有B®()的定制迷你植入物的骨反应。B®是一种通过物理气相沉积(Permedica Spa)在表面涂覆的氮化钛铌涂层。它是一种薄的陶瓷单层,非常坚硬,具有很高的耐磨性、耐刮擦性和耐腐蚀性[2]在SAOS-2在定制支架上接种后24、48和72小时测试了活性和粘附性。细胞活力(2x104个细胞)通过AlamarBlue®测定法进行评估[3],B®的细胞活力在统计学上高于其他两组(48和72小时,p值<0.05)。未观察到毒性反应。通过扫描电子显微镜分析粘附(104个细胞)[3]。细胞形态证实了其健康状态。细胞粘附在表面并增殖,72小时后完全覆盖机加工和B®的表面。对2名患者进行骨整合评估。拔牙后,放置3个MIB®。三个月后,在钻孔过程中,采集MIB®活检组织进行组织学处理(Donath方案)[3]。在所有切片中,MIB®都实现了良好的骨整合,新形成的骨高度矿化并组织成薄片(骨与植入物接触46.8%±9.15)。植入物线圈中填充了59.8%±4.23的新骨。髓腔内血管丰富,无炎症浸润。总之,B®是一种很有前途的涂层,能够在体外增强生存能力,并有利于体内骨整合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Histomorphometrical evaluation of cells and tissues in contact with a new anti-wear dental implant surface: Bioloy® coating
Dental implants rehabilitation of edentulous patients is the current accepted treatment to increase prosthetic stabilization. Various implant surface modifications have been tried to enhance osseointegration and to reduce the spread of detrimental metallic ions toward host tissues [1]. The aim of this preliminary study was to investigate in vitro the viability, proliferation and adhesion of a Bioloy® (B®) coating compared to machined and sandblasted surfaces and to assess histologically in vivo the bone response to customized mini-implants coated with B® () placed in the mandible of patients. B® is a titanium niobium nitride coating applied on surface by physical vapor deposition (Permedica Spa). It is a thin ceramic monolayer, extremely hard and with high resistance against wear, scratches and corrosion [2] Viability and adhesion was tested at 24, 48 and 72 hours after seeding of SAOS-2 on customised scaffold. Cell viability (2x104 cells) was evaluated by AlamarBlue® assay [3] and it resulted statistically higher on B® than in the other 2 groups (48 and 72 hours, p-value<0.05). No toxic response was observed. Adhesion (104 cells) was analysed by scanning electron microscope [3]. Cell morphology confirmed the healthy status. Cells adhered to the surface and proliferated, covering completely the surfaces of machined and B® at 72 hours. Osseointegration was evaluated in 2 patients. After tooth extraction, 3 MIB® were placed. Three months later, during drilling process, the biopsies with MIB® were harvested for histological processing (Donath’ protocol) [3]. In all sections MIB® resulted well osseointegrated and newly formed bone was highly mineralized and organized in lamellae (bone to implant contact 46.8%±9.15). The implant coils were filled with new bone for the 59.8% ± 4.23. Medullary spaces were rich in blood vessels without inflammatory infiltrate. In conclusion, B® is a promising coating able to enhance the viability in vitro and to favor the osseointegration in vivo.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
1
期刊介绍: The Italian Journal of Anatomy and Embryology, founded in 1901 by Giulio Chiarugi, Anatomist at Florence University, is a peer-reviewed journal sponsored by the Italian Society of Anatomy and Embryology. The journal publishes original papers, invited review articles, historical article, commentaries, obituitary, and book reviews. Its main focus is to understand anatomy through an analysis of structure, function, development and evolution. Priority will be given to studies of that clearly articulate their relevance to the anatomical community. Focal areas include: experimental studies, contributions based on molecular and cell biology and on the application of modern imaging techniques; comparative functional morphology; developmental biology; functional human anatomy; methodological innovations in anatomical research; significant advances in anatomical education. Studies that are essentially descriptive anatomy are appropriate only if they communicate clearly a broader functional or evolutionary significance. All papers should be submitted in English and must be original works that are unpublished and not under consideration by another journal. An international Editorial Board and reviewers from the anatomical disciplines guarantee a rapid review of your paper within two to three weeks after submission.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信