基于外磁信息的隐极同步发电机内部电磁缺陷识别

IF 0.3 Q4 ENERGY & FUELS
A. Morozov, Ju.B. Kazakov, N. Morozov, S. Nesterov
{"title":"基于外磁信息的隐极同步发电机内部电磁缺陷识别","authors":"A. Morozov, Ju.B. Kazakov, N. Morozov, S. Nesterov","doi":"10.52254/1857-0070.2022.3-55.03","DOIUrl":null,"url":null,"abstract":"The objectives of the work are to develop a non-contact method of detecting internal electromagnetic defects in synchronous generators based on the analysis of asymmetry of the external magnetic field distribution resulting from damage, establishing the relationship of defects of a generator with the pattern of field distribution, identifying diagnostic signs for the defects. These objectives are achieved by developing and using three-dimensional finite-element models of the external magnetic field of synchronous generators, by studying and analyzing the results of numerical simulation of external magnetic fields, by comparing the simulation results with experimental data. Significant results of the work include the improvement of the non-contact method for detecting internal electromagnetic defects in synchronous generators, revealing how defects of the generator manifest themselves in the asymmetry of magnetic field distribution, and detecting the correlation of field asymmetry with the type and severity of defects. For implicit-pole synchronous generators, it is reasonable to use the field asymmetry coefficient determined by the shift in the magnetic field distribution caused by field coils damage. The sign of the coefficient indicates the pole with a damaged field coil. The value of the coefficient characterizes the severity of damage to the field coils, with a critical value of 0.1. The significance of the results lies in the possibility of timely and non-contact diagnostics of internal electromagnetic defects of implicitpole synchronous generators, which can significantly reduce the economic damage from failures of generators without installation of diagnostic sensors of damage inside the generators.","PeriodicalId":41974,"journal":{"name":"Problemele Energeticii Regionale","volume":" ","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Identification of Internal Electromagnetic Defects of Implicit-Pole Synchronous Generators Based on the Information of its External Magnetic\",\"authors\":\"A. Morozov, Ju.B. Kazakov, N. Morozov, S. Nesterov\",\"doi\":\"10.52254/1857-0070.2022.3-55.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objectives of the work are to develop a non-contact method of detecting internal electromagnetic defects in synchronous generators based on the analysis of asymmetry of the external magnetic field distribution resulting from damage, establishing the relationship of defects of a generator with the pattern of field distribution, identifying diagnostic signs for the defects. These objectives are achieved by developing and using three-dimensional finite-element models of the external magnetic field of synchronous generators, by studying and analyzing the results of numerical simulation of external magnetic fields, by comparing the simulation results with experimental data. Significant results of the work include the improvement of the non-contact method for detecting internal electromagnetic defects in synchronous generators, revealing how defects of the generator manifest themselves in the asymmetry of magnetic field distribution, and detecting the correlation of field asymmetry with the type and severity of defects. For implicit-pole synchronous generators, it is reasonable to use the field asymmetry coefficient determined by the shift in the magnetic field distribution caused by field coils damage. The sign of the coefficient indicates the pole with a damaged field coil. The value of the coefficient characterizes the severity of damage to the field coils, with a critical value of 0.1. The significance of the results lies in the possibility of timely and non-contact diagnostics of internal electromagnetic defects of implicitpole synchronous generators, which can significantly reduce the economic damage from failures of generators without installation of diagnostic sensors of damage inside the generators.\",\"PeriodicalId\":41974,\"journal\":{\"name\":\"Problemele Energeticii Regionale\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Problemele Energeticii Regionale\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52254/1857-0070.2022.3-55.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Problemele Energeticii Regionale","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52254/1857-0070.2022.3-55.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

本文的工作目标是在分析同步发电机损坏引起的外磁场分布不对称的基础上,建立同步发电机缺陷与磁场分布模式的关系,确定缺陷的诊断标志,建立同步发电机内部电磁缺陷的非接触检测方法。通过建立和应用同步发电机外磁场的三维有限元模型,研究和分析外磁场的数值模拟结果,并将模拟结果与实验数据进行比较,实现了上述目标。改进了同步发电机内部电磁缺陷的非接触检测方法,揭示了同步发电机内部电磁缺陷在磁场分布不对称性中的表现,检测了磁场不对称性与缺陷类型和严重程度的相关性。对于隐极同步发电机,采用由磁场线圈损坏引起的磁场分布位移决定的磁场不对称系数是合理的。系数的符号表示有损坏的磁场线圈的极。该系数的值表征了磁场线圈损坏的严重程度,临界值为0.1。研究结果的意义在于,可以在不安装发电机内部损伤诊断传感器的情况下,对隐极同步发电机内部电磁缺陷进行及时、非接触诊断,大大减少发电机故障造成的经济损失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Identification of Internal Electromagnetic Defects of Implicit-Pole Synchronous Generators Based on the Information of its External Magnetic
The objectives of the work are to develop a non-contact method of detecting internal electromagnetic defects in synchronous generators based on the analysis of asymmetry of the external magnetic field distribution resulting from damage, establishing the relationship of defects of a generator with the pattern of field distribution, identifying diagnostic signs for the defects. These objectives are achieved by developing and using three-dimensional finite-element models of the external magnetic field of synchronous generators, by studying and analyzing the results of numerical simulation of external magnetic fields, by comparing the simulation results with experimental data. Significant results of the work include the improvement of the non-contact method for detecting internal electromagnetic defects in synchronous generators, revealing how defects of the generator manifest themselves in the asymmetry of magnetic field distribution, and detecting the correlation of field asymmetry with the type and severity of defects. For implicit-pole synchronous generators, it is reasonable to use the field asymmetry coefficient determined by the shift in the magnetic field distribution caused by field coils damage. The sign of the coefficient indicates the pole with a damaged field coil. The value of the coefficient characterizes the severity of damage to the field coils, with a critical value of 0.1. The significance of the results lies in the possibility of timely and non-contact diagnostics of internal electromagnetic defects of implicitpole synchronous generators, which can significantly reduce the economic damage from failures of generators without installation of diagnostic sensors of damage inside the generators.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
33.30%
发文量
38
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信