儿童使用Mydriatic滴眼液前后明显屈光的屈光测量标准化潜力

Yenling Cho, Xue Chen, Lishan Huang, Xue Yang, Yuhua Wang
{"title":"儿童使用Mydriatic滴眼液前后明显屈光的屈光测量标准化潜力","authors":"Yenling Cho, Xue Chen, Lishan Huang, Xue Yang, Yuhua Wang","doi":"10.1166/nnl.2020.3140","DOIUrl":null,"url":null,"abstract":"This study aimed to standardize the refractive measures using manifest refraction (MR) before and after using mydriatic eyedrops, and to explore the potential impact of age on the MR differences before mydriatic eyedrops (MRM), after rapid pupil dilation (MRRPD), and after slow pupil\n dilation (MRSPD). Three hundred sixty-two participants, aged 3–18 years were recruited from January 1, 2018, to September 30, 2018, using cluster sampling. MRM, MRRPD, and MRSPD were applied for measuring sphere and cylinder in the left and right eyes. At the initial inspection stage\n there were no significant differences between the MRM and MRRPD groups for sphere and cylinder values in the left and right eyes (P > 0 05). A significant difference was found for the sphere value in the left (P < 0 001) and right eyes (P < 0 001) among the MRM,\n MRRPD, and MRSPD groups, whereas there was no significant difference in cylinder value in the left (P = 0 691) and right eyes (P = 0 172) among groups at the review stage. The sphere value in the left and right eyes was significantly different among the MRM, MRRPD, and MRSPD\n groups for children aged 3–6 years, and there was a significant difference among groups for the sphere value in the right eye for children aged 7–11 years. There were no significant differences between the MRM and MRRPD groups in terms of sphere or cylinder values in the left and\n right eyes of children aged 12–18 years. The study findings indicate the results of sphere and cylinder measurements in the left and right eyes are consistent for MRM and MRRPD during the initial inspection stage, without any effect of the age of the children. However, the results of\n sphere measurements in the left and right eye were significantly different between the MRM, MRRPD, and MRSPD groups, especially for younger children.","PeriodicalId":18871,"journal":{"name":"Nanoscience and Nanotechnology Letters","volume":"12 1","pages":"563-569"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Potential for Standardization of Refractive Measures for Manifest Refraction Before and After Using Mydriatic Eyedrops in Children\",\"authors\":\"Yenling Cho, Xue Chen, Lishan Huang, Xue Yang, Yuhua Wang\",\"doi\":\"10.1166/nnl.2020.3140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aimed to standardize the refractive measures using manifest refraction (MR) before and after using mydriatic eyedrops, and to explore the potential impact of age on the MR differences before mydriatic eyedrops (MRM), after rapid pupil dilation (MRRPD), and after slow pupil\\n dilation (MRSPD). Three hundred sixty-two participants, aged 3–18 years were recruited from January 1, 2018, to September 30, 2018, using cluster sampling. MRM, MRRPD, and MRSPD were applied for measuring sphere and cylinder in the left and right eyes. At the initial inspection stage\\n there were no significant differences between the MRM and MRRPD groups for sphere and cylinder values in the left and right eyes (P > 0 05). A significant difference was found for the sphere value in the left (P < 0 001) and right eyes (P < 0 001) among the MRM,\\n MRRPD, and MRSPD groups, whereas there was no significant difference in cylinder value in the left (P = 0 691) and right eyes (P = 0 172) among groups at the review stage. The sphere value in the left and right eyes was significantly different among the MRM, MRRPD, and MRSPD\\n groups for children aged 3–6 years, and there was a significant difference among groups for the sphere value in the right eye for children aged 7–11 years. There were no significant differences between the MRM and MRRPD groups in terms of sphere or cylinder values in the left and\\n right eyes of children aged 12–18 years. The study findings indicate the results of sphere and cylinder measurements in the left and right eyes are consistent for MRM and MRRPD during the initial inspection stage, without any effect of the age of the children. However, the results of\\n sphere measurements in the left and right eye were significantly different between the MRM, MRRPD, and MRSPD groups, especially for younger children.\",\"PeriodicalId\":18871,\"journal\":{\"name\":\"Nanoscience and Nanotechnology Letters\",\"volume\":\"12 1\",\"pages\":\"563-569\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nanoscience and Nanotechnology Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1166/nnl.2020.3140\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanoscience and Nanotechnology Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1166/nnl.2020.3140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在规范散瞳滴眼液使用前后明显屈光(MR)的屈光测量,探讨年龄对散瞳滴眼液使用前(MRM)、快速瞳孔扩张(MRRPD)和缓慢瞳孔扩张(MRSPD)后MR差异的潜在影响。采用整群抽样方法,于2018年1月1日至2018年9月30日招募了362名年龄在3-18岁之间的参与者。采用MRM、MRRPD、MRSPD分别测量左、右眼的球体和圆柱体。在初始检查阶段,MRM组和MRRPD组左、右眼的球体和圆柱体值无显著差异(P >0 00 05)。MRM组、MRRPD组和MRSPD组的左、右眼圆球值差异有统计学意义(P < 0.001),而左、右眼圆球值差异无统计学意义(P = 0.691)。3 ~ 6岁儿童MRM、MRRPD、MRSPD组左、右眼球值差异有统计学意义,7 ~ 11岁儿童右眼球值组间差异有统计学意义。MRM组和MRRPD组在12-18岁儿童左右眼的球体或圆柱体值方面无显著差异。研究结果表明,在初始检查阶段,MRM和MRRPD在左右眼的球体和圆柱体测量结果是一致的,不受儿童年龄的影响。然而,左眼和右眼的球体测量结果在MRM、MRRPD和MRSPD组之间存在显著差异,尤其是在年龄较小的儿童中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Potential for Standardization of Refractive Measures for Manifest Refraction Before and After Using Mydriatic Eyedrops in Children
This study aimed to standardize the refractive measures using manifest refraction (MR) before and after using mydriatic eyedrops, and to explore the potential impact of age on the MR differences before mydriatic eyedrops (MRM), after rapid pupil dilation (MRRPD), and after slow pupil dilation (MRSPD). Three hundred sixty-two participants, aged 3–18 years were recruited from January 1, 2018, to September 30, 2018, using cluster sampling. MRM, MRRPD, and MRSPD were applied for measuring sphere and cylinder in the left and right eyes. At the initial inspection stage there were no significant differences between the MRM and MRRPD groups for sphere and cylinder values in the left and right eyes (P > 0 05). A significant difference was found for the sphere value in the left (P < 0 001) and right eyes (P < 0 001) among the MRM, MRRPD, and MRSPD groups, whereas there was no significant difference in cylinder value in the left (P = 0 691) and right eyes (P = 0 172) among groups at the review stage. The sphere value in the left and right eyes was significantly different among the MRM, MRRPD, and MRSPD groups for children aged 3–6 years, and there was a significant difference among groups for the sphere value in the right eye for children aged 7–11 years. There were no significant differences between the MRM and MRRPD groups in terms of sphere or cylinder values in the left and right eyes of children aged 12–18 years. The study findings indicate the results of sphere and cylinder measurements in the left and right eyes are consistent for MRM and MRRPD during the initial inspection stage, without any effect of the age of the children. However, the results of sphere measurements in the left and right eye were significantly different between the MRM, MRRPD, and MRSPD groups, especially for younger children.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nanoscience and Nanotechnology Letters
Nanoscience and Nanotechnology Letters Physical, Chemical & Earth Sciences-MATERIALS SCIENCE, MULTIDISCIPLINARY
自引率
0.00%
发文量
0
审稿时长
2.6 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信