微控制器和一个基于PLC的通信系统,主机连接和C-Command RS232协议

Dewi Rizani Ruwahida Ruwahida, I. Rachman, H. A. Widodo, R. Adhitya, Yuda Irawan
{"title":"微控制器和一个基于PLC的通信系统,主机连接和C-Command RS232协议","authors":"Dewi Rizani Ruwahida Ruwahida, I. Rachman, H. A. Widodo, R. Adhitya, Yuda Irawan","doi":"10.35970/infotekmesin.v14i2.1924","DOIUrl":null,"url":null,"abstract":"The communication between microcontrollers and PLC has become an important technology development that needs to be enhanced. One of the reasons for the communication between these two devices is to facilitate the input process of data or information from sensors, which are responsible for detecting or measuring specific parameters. Not all sensors can be directly read by PLC, as some sensors have their own communication protocols or specific libraries that are not directly supported by PLC. Microcontrollers are often used as intermediaries between sensors and PLC. Microcontrollers can read sensor data and then convert it into a format that can be understood by PLC. Microcontrollers can perform flat processing tasks such as conversion and status evaluation to provide more relevant data, and then send this data to the PLC through a compatible communication protocol. In this study, the communication protocol used is the Host Link serial communication using the C-mode Command method. The communication testing conducted using 10 different data samples resulted in accurate values with an error percentage of 0%.","PeriodicalId":33598,"journal":{"name":"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sistem Komunikasi Mikrokontroler dan PLC Berbasis Komunikasi Serial Host Link dan Protokol C-Command RS232\",\"authors\":\"Dewi Rizani Ruwahida Ruwahida, I. Rachman, H. A. Widodo, R. Adhitya, Yuda Irawan\",\"doi\":\"10.35970/infotekmesin.v14i2.1924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The communication between microcontrollers and PLC has become an important technology development that needs to be enhanced. One of the reasons for the communication between these two devices is to facilitate the input process of data or information from sensors, which are responsible for detecting or measuring specific parameters. Not all sensors can be directly read by PLC, as some sensors have their own communication protocols or specific libraries that are not directly supported by PLC. Microcontrollers are often used as intermediaries between sensors and PLC. Microcontrollers can read sensor data and then convert it into a format that can be understood by PLC. Microcontrollers can perform flat processing tasks such as conversion and status evaluation to provide more relevant data, and then send this data to the PLC through a compatible communication protocol. In this study, the communication protocol used is the Host Link serial communication using the C-mode Command method. The communication testing conducted using 10 different data samples resulted in accurate values with an error percentage of 0%.\",\"PeriodicalId\":33598,\"journal\":{\"name\":\"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35970/infotekmesin.v14i2.1924\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infotekmesin Media Komunikasi Ilmiah Politeknik Cilacap","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35970/infotekmesin.v14i2.1924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

微控制器与PLC之间的通信已成为一项需要加强的重要技术发展。这两个设备之间进行通信的原因之一是促进来自传感器的数据或信息的输入过程,传感器负责检测或测量特定参数。并非所有传感器都可以由PLC直接读取,因为一些传感器有自己的通信协议或特定的库,而PLC不直接支持这些协议或库。微控制器经常被用作传感器和PLC之间的中介。微控制器可以读取传感器数据,然后将其转换为PLC可以理解的格式。微控制器可以执行转换和状态评估等平面处理任务,以提供更多相关数据,然后通过兼容的通信协议将这些数据发送到PLC。在本研究中,使用的通信协议是使用C模式命令方法的Host Link串行通信。使用10个不同的数据样本进行的通信测试得出了准确的值,误差百分比为0%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sistem Komunikasi Mikrokontroler dan PLC Berbasis Komunikasi Serial Host Link dan Protokol C-Command RS232
The communication between microcontrollers and PLC has become an important technology development that needs to be enhanced. One of the reasons for the communication between these two devices is to facilitate the input process of data or information from sensors, which are responsible for detecting or measuring specific parameters. Not all sensors can be directly read by PLC, as some sensors have their own communication protocols or specific libraries that are not directly supported by PLC. Microcontrollers are often used as intermediaries between sensors and PLC. Microcontrollers can read sensor data and then convert it into a format that can be understood by PLC. Microcontrollers can perform flat processing tasks such as conversion and status evaluation to provide more relevant data, and then send this data to the PLC through a compatible communication protocol. In this study, the communication protocol used is the Host Link serial communication using the C-mode Command method. The communication testing conducted using 10 different data samples resulted in accurate values with an error percentage of 0%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
30
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信