单轴载荷作用下压实钢丝绳的热弹性效应

IF 3.7 3区 工程技术 Q1 INSTRUMENTS & INSTRUMENTATION
Piotr Szade, Mariusz Szot, B. Kubiś
{"title":"单轴载荷作用下压实钢丝绳的热弹性效应","authors":"Piotr Szade, Mariusz Szot, B. Kubiś","doi":"10.1080/17686733.2020.1768495","DOIUrl":null,"url":null,"abstract":"ABSTRACT The aim of the research presented in this work was to verify the occurrence of the thermoelastic effect in compacted steel wire ropes for future research applications and TSA methods. It was examined using a Testo 890 thermal camera during tests consisting of 10 cycles of loading of rope samples to levels under the yield stress, performed on a tensile strength machine. Average measured changes of temperature caused by a 1000 MPa change of stress were 0.8 K during loading and 1.0 K during unloading. It was found that rapid unloading caused temperature changes that were closer to the theoretical values calculated for an isotropic body and adiabatic conditions. Probable reasons for those differences were investigated. Furthermore, temperatures of samples recorded after each cycle of loading were analysed. Heating of samples during cycles of elastic elongation was observed, pointing to exothermal processes taking place in the internal structure of the ropes. Application of IR cameras to detect dynamic load changes using the thermoelastic effect in steel wire ropes was proposed and evaluated. Usage of described novelty method in inspection of steel wire ropes during the operation was discussed.","PeriodicalId":54525,"journal":{"name":"Quantitative Infrared Thermography Journal","volume":"18 1","pages":"252 - 268"},"PeriodicalIF":3.7000,"publicationDate":"2020-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/17686733.2020.1768495","citationCount":"8","resultStr":"{\"title\":\"Thermoelastic effect in compacted steel wire ropes under uniaxial loading\",\"authors\":\"Piotr Szade, Mariusz Szot, B. Kubiś\",\"doi\":\"10.1080/17686733.2020.1768495\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT The aim of the research presented in this work was to verify the occurrence of the thermoelastic effect in compacted steel wire ropes for future research applications and TSA methods. It was examined using a Testo 890 thermal camera during tests consisting of 10 cycles of loading of rope samples to levels under the yield stress, performed on a tensile strength machine. Average measured changes of temperature caused by a 1000 MPa change of stress were 0.8 K during loading and 1.0 K during unloading. It was found that rapid unloading caused temperature changes that were closer to the theoretical values calculated for an isotropic body and adiabatic conditions. Probable reasons for those differences were investigated. Furthermore, temperatures of samples recorded after each cycle of loading were analysed. Heating of samples during cycles of elastic elongation was observed, pointing to exothermal processes taking place in the internal structure of the ropes. Application of IR cameras to detect dynamic load changes using the thermoelastic effect in steel wire ropes was proposed and evaluated. Usage of described novelty method in inspection of steel wire ropes during the operation was discussed.\",\"PeriodicalId\":54525,\"journal\":{\"name\":\"Quantitative Infrared Thermography Journal\",\"volume\":\"18 1\",\"pages\":\"252 - 268\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2020-05-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/17686733.2020.1768495\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quantitative Infrared Thermography Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/17686733.2020.1768495\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantitative Infrared Thermography Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17686733.2020.1768495","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 8

摘要

摘要本文研究的目的是验证压实钢丝绳中热弹性效应的存在,以供未来的研究应用和TSA方法。在拉伸强度机上进行的测试中,使用Testo 890热像仪对其进行了检查,测试包括将绳索样品加载到屈服应力下的水平的10个循环。由1000MPa的应力变化引起的温度的平均测量变化在加载期间为0.8K,在卸载期间为1.0K。研究发现,快速卸载引起的温度变化更接近各向同性体和绝热条件下计算的理论值。调查了这些差异的可能原因。此外,对每个加载循环后记录的样品的温度进行了分析。观察到样品在弹性伸长率循环过程中的加热,表明绳索的内部结构发生了放热过程。提出并评价了红外摄像机在利用钢丝绳热弹性效应检测动态载荷变化方面的应用。讨论了所述新颖方法在钢丝绳运行过程中的检测中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermoelastic effect in compacted steel wire ropes under uniaxial loading
ABSTRACT The aim of the research presented in this work was to verify the occurrence of the thermoelastic effect in compacted steel wire ropes for future research applications and TSA methods. It was examined using a Testo 890 thermal camera during tests consisting of 10 cycles of loading of rope samples to levels under the yield stress, performed on a tensile strength machine. Average measured changes of temperature caused by a 1000 MPa change of stress were 0.8 K during loading and 1.0 K during unloading. It was found that rapid unloading caused temperature changes that were closer to the theoretical values calculated for an isotropic body and adiabatic conditions. Probable reasons for those differences were investigated. Furthermore, temperatures of samples recorded after each cycle of loading were analysed. Heating of samples during cycles of elastic elongation was observed, pointing to exothermal processes taking place in the internal structure of the ropes. Application of IR cameras to detect dynamic load changes using the thermoelastic effect in steel wire ropes was proposed and evaluated. Usage of described novelty method in inspection of steel wire ropes during the operation was discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Quantitative Infrared Thermography Journal
Quantitative Infrared Thermography Journal Physics and Astronomy-Instrumentation
CiteScore
6.80
自引率
12.00%
发文量
17
审稿时长
>12 weeks
期刊介绍: The Quantitative InfraRed Thermography Journal (QIRT) provides a forum for industry and academia to discuss the latest developments of instrumentation, theoretical and experimental practices, data reduction, and image processing related to infrared thermography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信