食管传递时间显像评价食管运动

Pub Date : 2017-09-01 DOI:10.12816/0047640
Tareq Hamed Al Taei, S. Aly, A. Fawzy
{"title":"食管传递时间显像评价食管运动","authors":"Tareq Hamed Al Taei, S. Aly, A. Fawzy","doi":"10.12816/0047640","DOIUrl":null,"url":null,"abstract":"An eighty-three-year-old male with a known case of gastroesophageal adenocarcinoma presented with persistent vomiting and chest pain even after esophageal stent was inserted. Esophageal scintigraphy was performed to assess the esophagus motility. A 9995 micro-Curi Tc-99 m sulfur colloid with 15 ml water as bolus was used; immediately thereafter sequential dynamic images for the chest region in anterior projection were performed: one second per frame for 60 seconds, followed by 30 seconds per frame for 10 minutes while the patient took multiple dry swallows every 30 seconds. Images were compressed and displayed in five seconds per frame for initial 60-second images followed by two minutes per frame for the remaining 10-minute dynamic study. Timeactivity curve for the whole esophagus and each of its upper, middle and lower thirds were generated.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Esophageal Transit Time Scintigraphy in the Assessment of the Esophagus Motility\",\"authors\":\"Tareq Hamed Al Taei, S. Aly, A. Fawzy\",\"doi\":\"10.12816/0047640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An eighty-three-year-old male with a known case of gastroesophageal adenocarcinoma presented with persistent vomiting and chest pain even after esophageal stent was inserted. Esophageal scintigraphy was performed to assess the esophagus motility. A 9995 micro-Curi Tc-99 m sulfur colloid with 15 ml water as bolus was used; immediately thereafter sequential dynamic images for the chest region in anterior projection were performed: one second per frame for 60 seconds, followed by 30 seconds per frame for 10 minutes while the patient took multiple dry swallows every 30 seconds. Images were compressed and displayed in five seconds per frame for initial 60-second images followed by two minutes per frame for the remaining 10-minute dynamic study. Timeactivity curve for the whole esophagus and each of its upper, middle and lower thirds were generated.\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12816/0047640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12816/0047640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一例83岁男性胃食管腺癌患者在食管支架置入后仍出现持续呕吐及胸痛。食管显像评估食管运动。采用9995微curi Tc-99 m硫胶体,15ml水为丸剂;随后立即对胸部前投影区域进行连续动态成像:每帧1秒,连续60秒,然后每帧30秒,连续10分钟,同时患者每30秒进行多次干吞。在最初的60秒图像中,图像被压缩并以每帧5秒的时间显示,然后在剩余的10分钟动态研究中,每帧2分钟。生成全食管及其上、中、下三分之一时间活度曲线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享
查看原文
Esophageal Transit Time Scintigraphy in the Assessment of the Esophagus Motility
An eighty-three-year-old male with a known case of gastroesophageal adenocarcinoma presented with persistent vomiting and chest pain even after esophageal stent was inserted. Esophageal scintigraphy was performed to assess the esophagus motility. A 9995 micro-Curi Tc-99 m sulfur colloid with 15 ml water as bolus was used; immediately thereafter sequential dynamic images for the chest region in anterior projection were performed: one second per frame for 60 seconds, followed by 30 seconds per frame for 10 minutes while the patient took multiple dry swallows every 30 seconds. Images were compressed and displayed in five seconds per frame for initial 60-second images followed by two minutes per frame for the remaining 10-minute dynamic study. Timeactivity curve for the whole esophagus and each of its upper, middle and lower thirds were generated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信