生物样品中MLH1、MSH2、MSH6、PMS2和KRAS的分子识别和定量

Raluca-Ioana Ștefan-van Staden, Ruxandra-Maria Ilie-Mihai, M. Coroş, S. Pruneanu
{"title":"生物样品中MLH1、MSH2、MSH6、PMS2和KRAS的分子识别和定量","authors":"Raluca-Ioana Ștefan-van Staden, Ruxandra-Maria Ilie-Mihai, M. Coroş, S. Pruneanu","doi":"10.1149/2754-2726/ac9740","DOIUrl":null,"url":null,"abstract":"Two stochastic sensors based on modification of nitrogen and boron dopped exfoliated graphene with a complex of protoporphyrin and cobalt, were used for molecular recognition and quantification of MLH1, MSH2, MSH6, PMS2 and KRAS biomarkers in biological samples (whole blood, urine, saliva, tumoral tissue). Limits of determination of fg ml−1 magnitude order and broad linear concentration ranges favorized their determination from very low to higher concentrations in biological samples. The student t-test showed that there is no significant difference between the results obtained by utilizing the two microsensors for screening tests, at 99% confidence level, the results obtained being lowr than the tabulated value.","PeriodicalId":72870,"journal":{"name":"ECS sensors plus","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Molecular Recognition and Quantification of MLH1, MSH2, MSH6, PMS2, and KRAS in Biological Samples\",\"authors\":\"Raluca-Ioana Ștefan-van Staden, Ruxandra-Maria Ilie-Mihai, M. Coroş, S. Pruneanu\",\"doi\":\"10.1149/2754-2726/ac9740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two stochastic sensors based on modification of nitrogen and boron dopped exfoliated graphene with a complex of protoporphyrin and cobalt, were used for molecular recognition and quantification of MLH1, MSH2, MSH6, PMS2 and KRAS biomarkers in biological samples (whole blood, urine, saliva, tumoral tissue). Limits of determination of fg ml−1 magnitude order and broad linear concentration ranges favorized their determination from very low to higher concentrations in biological samples. The student t-test showed that there is no significant difference between the results obtained by utilizing the two microsensors for screening tests, at 99% confidence level, the results obtained being lowr than the tabulated value.\",\"PeriodicalId\":72870,\"journal\":{\"name\":\"ECS sensors plus\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ECS sensors plus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1149/2754-2726/ac9740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS sensors plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/2754-2726/ac9740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

两个基于氮和硼掺杂的剥离石墨烯与原卟啉和钴复合物修饰的随机传感器用于生物样品(全血、尿液、唾液、肿瘤组织)中MLH1、MSH2、MSH6、PMS2和KRAS生物标志物的分子识别和定量。fg ml−1数量级的测定限值和宽的线性浓度范围有利于生物样品中从非常低到更高浓度的测定。学生t检验表明,在99%的置信水平下,使用两个微传感器进行筛选测试所获得的结果之间没有显著差异,所获得的值低于表中的值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Molecular Recognition and Quantification of MLH1, MSH2, MSH6, PMS2, and KRAS in Biological Samples
Two stochastic sensors based on modification of nitrogen and boron dopped exfoliated graphene with a complex of protoporphyrin and cobalt, were used for molecular recognition and quantification of MLH1, MSH2, MSH6, PMS2 and KRAS biomarkers in biological samples (whole blood, urine, saliva, tumoral tissue). Limits of determination of fg ml−1 magnitude order and broad linear concentration ranges favorized their determination from very low to higher concentrations in biological samples. The student t-test showed that there is no significant difference between the results obtained by utilizing the two microsensors for screening tests, at 99% confidence level, the results obtained being lowr than the tabulated value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信