超市简化校准建筑模拟模型的开发,用于拟议的ECM和控制策略影响评估

IF 1.5 4区 工程技术 Q3 CONSTRUCTION & BUILDING TECHNOLOGY
N. Kunwar, M. Bhandari, Piljae Im, Brian Fricke, Jason DeGraw, T. Kuruganti
{"title":"超市简化校准建筑模拟模型的开发,用于拟议的ECM和控制策略影响评估","authors":"N. Kunwar, M. Bhandari, Piljae Im, Brian Fricke, Jason DeGraw, T. Kuruganti","doi":"10.1177/01436244221137241","DOIUrl":null,"url":null,"abstract":"Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. The paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application : This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.","PeriodicalId":50724,"journal":{"name":"Building Services Engineering Research & Technology","volume":"44 1","pages":"25 - 44"},"PeriodicalIF":1.5000,"publicationDate":"2022-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation\",\"authors\":\"N. Kunwar, M. Bhandari, Piljae Im, Brian Fricke, Jason DeGraw, T. Kuruganti\",\"doi\":\"10.1177/01436244221137241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. The paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application : This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.\",\"PeriodicalId\":50724,\"journal\":{\"name\":\"Building Services Engineering Research & Technology\",\"volume\":\"44 1\",\"pages\":\"25 - 44\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2022-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Building Services Engineering Research & Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01436244221137241\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Services Engineering Research & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01436244221137241","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

校准的建筑能耗模拟是实现建筑节能的重要途径,但一些方法对信息的要求很高。对于超市和其他所谓的“大卖场”零售商店来说尤其如此。超市的另一个特点是这些建筑中的暖通空调(HVAC)和制冷系统之间的重要相互作用。这些建筑可能包含各种各样的系统和一定程度的负载多样性,这使得校准建模成为一项挑战。本文介绍了一种简化的方法,该方法使用OpenStudio和EnergyPlus将已知的建筑参数与“典型”参数结合起来,从而得到易于校准的简化建筑。该方法应用于田纳西州纳什维尔的一家大型商店,并获得了一个校准模型,用于研究潜在的节能措施。本文还探讨了整个建筑能源建模工具的能力,如EnergyPlus,用于模拟暖通空调控制和序列及其影响评估。虽然模型的简单性排除了一些措施,但发现了一些提高模型效率的措施,并证明了简化建模方法的有效性。实际应用:本文介绍了一种混合方法,利用从实际建筑中获得的有限信息,结合同类型“典型”建筑的特征,进行建筑能源模型校准。这种混合方法也适用于本文讨论的其他建筑类型,使用来自实际建筑的有限信息来校准建筑能源模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation
Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. The paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application : This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Building Services Engineering Research & Technology
Building Services Engineering Research & Technology 工程技术-结构与建筑技术
CiteScore
4.30
自引率
5.90%
发文量
38
审稿时长
>12 weeks
期刊介绍: Building Services Engineering Research & Technology is one of the foremost, international peer reviewed journals that publishes the highest quality original research relevant to today’s Built Environment. Published in conjunction with CIBSE, this impressive journal reports on the latest research providing you with an invaluable guide to recent developments in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信