采用人类机器界面的概念,标准自动化系统的原型设计研究

Irwan Heryanto Eryk, Slamet Nurhadi
{"title":"采用人类机器界面的概念,标准自动化系统的原型设计研究","authors":"Irwan Heryanto Eryk, Slamet Nurhadi","doi":"10.33795/ELTEK.V16I1.84","DOIUrl":null,"url":null,"abstract":"This research is studying the automation of substation monitoring system especially in metering equipment. It was aimed to plan and implemented the substation design that monitored with SIMATIC WinCC program. The equipments are PLC, PM-710, SIMATIC WinCC, Movicon, relay, MCB, CT and Transformers. It used 3 phase power supply connected to several load of Resistor (R),Inductor (L), and Capacitor (C). PM-710 was used to measure the outgoing load datas that connected and saved to Personal Computer (PC). The experiment were using the varied load. Base on the module, the power substation simulated with WinCC and the reading metering datas such as real power, apparent power and power factor also frequency by MOVICON that displayed in the PC monitor.","PeriodicalId":53405,"journal":{"name":"Jurnal Eltek","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"STUDI PERENCANAAN PROTOTIPE SISTEM OTOMASI METERING GARDU INDUK MENGGUNAKAN KONSEP HUMAN MACHINE INTERFACE\",\"authors\":\"Irwan Heryanto Eryk, Slamet Nurhadi\",\"doi\":\"10.33795/ELTEK.V16I1.84\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research is studying the automation of substation monitoring system especially in metering equipment. It was aimed to plan and implemented the substation design that monitored with SIMATIC WinCC program. The equipments are PLC, PM-710, SIMATIC WinCC, Movicon, relay, MCB, CT and Transformers. It used 3 phase power supply connected to several load of Resistor (R),Inductor (L), and Capacitor (C). PM-710 was used to measure the outgoing load datas that connected and saved to Personal Computer (PC). The experiment were using the varied load. Base on the module, the power substation simulated with WinCC and the reading metering datas such as real power, apparent power and power factor also frequency by MOVICON that displayed in the PC monitor.\",\"PeriodicalId\":53405,\"journal\":{\"name\":\"Jurnal Eltek\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Eltek\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33795/ELTEK.V16I1.84\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Eltek","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33795/ELTEK.V16I1.84","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本课题主要研究变电站监控系统的自动化,尤其是计量设备的自动化。其目的是计划和实施用SIMATIC WinCC程序监控的变电站设计。设备包括PLC、PM-710、SIMATIC WinCC、Movicon、继电器、MCB、CT和变压器。它使用了连接到电阻器(R)、电感器(L)和电容器(C)几个负载的三相电源。PM-710用于测量连接并保存到个人计算机(PC)的输出负载数据。实验使用的是变化的负载。在该模块的基础上,用WinCC对变电站进行了仿真,并通过MOVICON读取了实际功率、视在功率和功率因数等计量数据,并将其显示在PC监视器上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
STUDI PERENCANAAN PROTOTIPE SISTEM OTOMASI METERING GARDU INDUK MENGGUNAKAN KONSEP HUMAN MACHINE INTERFACE
This research is studying the automation of substation monitoring system especially in metering equipment. It was aimed to plan and implemented the substation design that monitored with SIMATIC WinCC program. The equipments are PLC, PM-710, SIMATIC WinCC, Movicon, relay, MCB, CT and Transformers. It used 3 phase power supply connected to several load of Resistor (R),Inductor (L), and Capacitor (C). PM-710 was used to measure the outgoing load datas that connected and saved to Personal Computer (PC). The experiment were using the varied load. Base on the module, the power substation simulated with WinCC and the reading metering datas such as real power, apparent power and power factor also frequency by MOVICON that displayed in the PC monitor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
1
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信