S. Rengaraju, Radhakrishna G. Pillai
{"title":"LC3混凝土体系的长期腐蚀性能及使用寿命评估监测","authors":"S. Rengaraju, Radhakrishna G. Pillai","doi":"10.1080/21650373.2023.2246068","DOIUrl":null,"url":null,"abstract":"The performance of quenched and self-tempered (QST) steel bars embedded in concretes with Limestone calcined clay cement (LC3), fly ash (70% OPC and 30%fly ash – PFA), and traditional OPC was assessed in severe chloride environments. Additionally, the performance of commercially available, calcium nitrite-based inhibitors in the three binder systems was also evaluated. The specimens were subjected to an alternate wet-dry cycle using the ASTM G109 test method. The findings show that LC3 concrete performs better than the OPC and PFA systems with and without inhibitors. Furthermore, when the surface resistivity, ρ, is more than 37 kΩ.cm, the concrete has high ionic resistance and the macrocell current across the two rebars could not be established as described in ASTM G109 test method. This highlights the limitations of the ASTM G109 test method and the need for more sophisticated testing methods for assessing steel corrosion in highly resistive cementitious systems.","PeriodicalId":48521,"journal":{"name":"Journal of Sustainable Cement-Based Materials","volume":" ","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2023-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Long-term corrosion performance and monitoring for service life estimation of LC3 concrete systems\",\"authors\":\"S. Rengaraju, Radhakrishna G. Pillai\",\"doi\":\"10.1080/21650373.2023.2246068\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of quenched and self-tempered (QST) steel bars embedded in concretes with Limestone calcined clay cement (LC3), fly ash (70% OPC and 30%fly ash – PFA), and traditional OPC was assessed in severe chloride environments. Additionally, the performance of commercially available, calcium nitrite-based inhibitors in the three binder systems was also evaluated. The specimens were subjected to an alternate wet-dry cycle using the ASTM G109 test method. The findings show that LC3 concrete performs better than the OPC and PFA systems with and without inhibitors. Furthermore, when the surface resistivity, ρ, is more than 37 kΩ.cm, the concrete has high ionic resistance and the macrocell current across the two rebars could not be established as described in ASTM G109 test method. This highlights the limitations of the ASTM G109 test method and the need for more sophisticated testing methods for assessing steel corrosion in highly resistive cementitious systems.\",\"PeriodicalId\":48521,\"journal\":{\"name\":\"Journal of Sustainable Cement-Based Materials\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2023-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sustainable Cement-Based Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/21650373.2023.2246068\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sustainable Cement-Based Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/21650373.2023.2246068","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Long-term corrosion performance and monitoring for service life estimation of LC3 concrete systems
The performance of quenched and self-tempered (QST) steel bars embedded in concretes with Limestone calcined clay cement (LC3), fly ash (70% OPC and 30%fly ash – PFA), and traditional OPC was assessed in severe chloride environments. Additionally, the performance of commercially available, calcium nitrite-based inhibitors in the three binder systems was also evaluated. The specimens were subjected to an alternate wet-dry cycle using the ASTM G109 test method. The findings show that LC3 concrete performs better than the OPC and PFA systems with and without inhibitors. Furthermore, when the surface resistivity, ρ, is more than 37 kΩ.cm, the concrete has high ionic resistance and the macrocell current across the two rebars could not be established as described in ASTM G109 test method. This highlights the limitations of the ASTM G109 test method and the need for more sophisticated testing methods for assessing steel corrosion in highly resistive cementitious systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.60
自引率
15.90%
发文量
71
期刊介绍: The Journal of Sustainable Cement-Based Materials aims to publish theoretical and applied researches on materials, products and structures that incorporate cement. The journal is a forum for discussion of research on manufacture, hydration and performance of cement-based materials; novel experimental techniques; the latest analytical and modelling methods; the examination and the diagnosis of real cement and concrete structures; and the potential for improved cement-based materials. The journal welcomes original research papers, major reviews, rapid communications and selected conference papers. The Journal of Sustainable Cement-Based Materials covers a wide range of topics within its subject category, including but are not limited to: • raw materials and manufacture of cement • mixing, rheology and hydration • admixtures • structural characteristics and performance of cement-based materials • characterisation techniques and modeling • use of fibre in cement based-materials • degradation and repair of cement-based materials • novel testing techniques and applications • waste management
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信