{"title":"n个相似部分封闭串联光伏热平板集热器的灵敏度研究","authors":"Anuj Raturi, R. Patel, D. Singh","doi":"10.18186/thermal.1242825","DOIUrl":null,"url":null,"abstract":"A sensitivity study for N similar partly enclosed with photovoltaic thermal flat plate collectors with a series connection (N-PVT-FPCs) has been carried out in this research study. The analysis has been done for a typical day of May, wherein data for the ambient conditions of New Delhi (India) has been received from the India metrological department (IMD), Pune, India. In addition, further computational work has been carried out on the MATLAB programme for the daily heat gain of N-PVT-FPCs. One-at-a-time (OAT) methodology has been used for the sensitivity analysis. From the sensitivity analysis, it has been found that the heat gain from the proposed system is more sensitive with respect to the number of collectors (N) followed by inclination angle, mass flow rate (MFR) and packing factor (PF). The sensitivity figure has been found to be 0.08, 0.17, 0.25 and 0.94 for daily heat gain of N-PVT-FPCs with respect to PF, MFR, inclination angle and N, respectively.","PeriodicalId":45841,"journal":{"name":"Journal of Thermal Engineering","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A sensitivity study for n similar partly enclosed with photovoltaic thermal flat plate collectors having series connection\",\"authors\":\"Anuj Raturi, R. Patel, D. Singh\",\"doi\":\"10.18186/thermal.1242825\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A sensitivity study for N similar partly enclosed with photovoltaic thermal flat plate collectors with a series connection (N-PVT-FPCs) has been carried out in this research study. The analysis has been done for a typical day of May, wherein data for the ambient conditions of New Delhi (India) has been received from the India metrological department (IMD), Pune, India. In addition, further computational work has been carried out on the MATLAB programme for the daily heat gain of N-PVT-FPCs. One-at-a-time (OAT) methodology has been used for the sensitivity analysis. From the sensitivity analysis, it has been found that the heat gain from the proposed system is more sensitive with respect to the number of collectors (N) followed by inclination angle, mass flow rate (MFR) and packing factor (PF). The sensitivity figure has been found to be 0.08, 0.17, 0.25 and 0.94 for daily heat gain of N-PVT-FPCs with respect to PF, MFR, inclination angle and N, respectively.\",\"PeriodicalId\":45841,\"journal\":{\"name\":\"Journal of Thermal Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-01-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18186/thermal.1242825\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18186/thermal.1242825","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
A sensitivity study for n similar partly enclosed with photovoltaic thermal flat plate collectors having series connection
A sensitivity study for N similar partly enclosed with photovoltaic thermal flat plate collectors with a series connection (N-PVT-FPCs) has been carried out in this research study. The analysis has been done for a typical day of May, wherein data for the ambient conditions of New Delhi (India) has been received from the India metrological department (IMD), Pune, India. In addition, further computational work has been carried out on the MATLAB programme for the daily heat gain of N-PVT-FPCs. One-at-a-time (OAT) methodology has been used for the sensitivity analysis. From the sensitivity analysis, it has been found that the heat gain from the proposed system is more sensitive with respect to the number of collectors (N) followed by inclination angle, mass flow rate (MFR) and packing factor (PF). The sensitivity figure has been found to be 0.08, 0.17, 0.25 and 0.94 for daily heat gain of N-PVT-FPCs with respect to PF, MFR, inclination angle and N, respectively.
期刊介绍:
Journal of Thermal Enginering is aimed at giving a recognized platform to students, researchers, research scholars, teachers, authors and other professionals in the field of research in Thermal Engineering subjects, to publish their original and current research work to a wide, international audience. In order to achieve this goal, we will have applied for SCI-Expanded Index in 2021 after having an Impact Factor in 2020. The aim of the journal, published on behalf of Yildiz Technical University in Istanbul-Turkey, is to not only include actual, original and applied studies prepared on the sciences of heat transfer and thermodynamics, and contribute to the literature of engineering sciences on the national and international areas but also help the development of Mechanical Engineering. Engineers and academicians from disciplines of Power Plant Engineering, Energy Engineering, Building Services Engineering, HVAC Engineering, Solar Engineering, Wind Engineering, Nanoengineering, surface engineering, thin film technologies, and Computer Aided Engineering will be expected to benefit from this journal’s outputs.