{"title":"皮下植入式心脏复律除颤器的心外不适当电击:急诊科的处理","authors":"M. Santomauro","doi":"10.19080/jocct.2020.16.555941","DOIUrl":null,"url":null,"abstract":"The subcutaneous implantable cardioverter defibrillator (S-ICD) is an established treatment for the prevention of sudden cardiac death. In the S-ICD studies, inappropriate shocks (IAS) rate were reported to renge between 5% to 25% and to be mainly due to cardiac and noncardiac oversensing.","PeriodicalId":73635,"journal":{"name":"Journal of cardiology & cardiovascular therapy","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Extracardiac Inappropriate Shocks in Subcutaneous Implantable Cardioverter Defibrillator: Management in Emergency Department\",\"authors\":\"M. Santomauro\",\"doi\":\"10.19080/jocct.2020.16.555941\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The subcutaneous implantable cardioverter defibrillator (S-ICD) is an established treatment for the prevention of sudden cardiac death. In the S-ICD studies, inappropriate shocks (IAS) rate were reported to renge between 5% to 25% and to be mainly due to cardiac and noncardiac oversensing.\",\"PeriodicalId\":73635,\"journal\":{\"name\":\"Journal of cardiology & cardiovascular therapy\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cardiology & cardiovascular therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19080/jocct.2020.16.555941\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiology & cardiovascular therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19080/jocct.2020.16.555941","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Extracardiac Inappropriate Shocks in Subcutaneous Implantable Cardioverter Defibrillator: Management in Emergency Department
The subcutaneous implantable cardioverter defibrillator (S-ICD) is an established treatment for the prevention of sudden cardiac death. In the S-ICD studies, inappropriate shocks (IAS) rate were reported to renge between 5% to 25% and to be mainly due to cardiac and noncardiac oversensing.