D. I. Mahcicek, Korel D. Yildirim, Gokce Kasaci, O. Kocaturk
{"title":"磁共振成像引导前列腺活检液压针头输送系统的初步评价","authors":"D. I. Mahcicek, Korel D. Yildirim, Gokce Kasaci, O. Kocaturk","doi":"10.1115/1.4051610","DOIUrl":null,"url":null,"abstract":"\n In clinical routine, the prostate biopsy procedure is performed with the guidance of transrectal ultrasound (TRUS) imaging to diagnose prostate cancer. However, the TRUS-guided prostate biopsy brings reliability concerns due to the lack of contrast difference between prostate tissue and lesions. In this study, a novel hydraulic needle delivery system that is designed for performing magnetic resonance imaging (MRI)-guided prostate biopsy procedure with transperineal approach is introduced. The feasibility of the overall system was evaluated through in vitro phantom experiments under an MRI guidance. The in vitro experiments performed using a certified prostate phantom (incorporating MRI visible lesions). MRI experiments showed that overall hydraulic biopsy needle delivery system has excellent MRI compatibility (signal to noise ratio (SNR) loss < 3%), provides acceptable targeting accuracy (average 2.05±0.46 mm) and procedure time (average 40 min).","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preliminary Evaluation of Hydraulic Needle Delivery System for Magnetic Resonance Imaging-Guided Prostate Biopsy Procedures\",\"authors\":\"D. I. Mahcicek, Korel D. Yildirim, Gokce Kasaci, O. Kocaturk\",\"doi\":\"10.1115/1.4051610\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n In clinical routine, the prostate biopsy procedure is performed with the guidance of transrectal ultrasound (TRUS) imaging to diagnose prostate cancer. However, the TRUS-guided prostate biopsy brings reliability concerns due to the lack of contrast difference between prostate tissue and lesions. In this study, a novel hydraulic needle delivery system that is designed for performing magnetic resonance imaging (MRI)-guided prostate biopsy procedure with transperineal approach is introduced. The feasibility of the overall system was evaluated through in vitro phantom experiments under an MRI guidance. The in vitro experiments performed using a certified prostate phantom (incorporating MRI visible lesions). MRI experiments showed that overall hydraulic biopsy needle delivery system has excellent MRI compatibility (signal to noise ratio (SNR) loss < 3%), provides acceptable targeting accuracy (average 2.05±0.46 mm) and procedure time (average 40 min).\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4051610\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4051610","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Preliminary Evaluation of Hydraulic Needle Delivery System for Magnetic Resonance Imaging-Guided Prostate Biopsy Procedures
In clinical routine, the prostate biopsy procedure is performed with the guidance of transrectal ultrasound (TRUS) imaging to diagnose prostate cancer. However, the TRUS-guided prostate biopsy brings reliability concerns due to the lack of contrast difference between prostate tissue and lesions. In this study, a novel hydraulic needle delivery system that is designed for performing magnetic resonance imaging (MRI)-guided prostate biopsy procedure with transperineal approach is introduced. The feasibility of the overall system was evaluated through in vitro phantom experiments under an MRI guidance. The in vitro experiments performed using a certified prostate phantom (incorporating MRI visible lesions). MRI experiments showed that overall hydraulic biopsy needle delivery system has excellent MRI compatibility (signal to noise ratio (SNR) loss < 3%), provides acceptable targeting accuracy (average 2.05±0.46 mm) and procedure time (average 40 min).
期刊介绍:
The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.