尼泊尔加德满都改善家庭室内空气质量的缓解措施的影响

L. Edwards, P. Wilkinson, G. Rutter, Leslie Iverson, A. Milojevic
{"title":"尼泊尔加德满都改善家庭室内空气质量的缓解措施的影响","authors":"L. Edwards, P. Wilkinson, G. Rutter, Leslie Iverson, A. Milojevic","doi":"10.1088/2752-5309/acb663","DOIUrl":null,"url":null,"abstract":"Air purifiers (APs) and home sealing are interventions used to help protect U.S. diplomats against particle pollution in the home when working in polluted cities. We investigated the effect of these interventions on home indoor and personal PM2.5 exposure in Kathmandu, Nepal. Twenty-one participants underwent repeated 48 hour personal monitoring before and after intervention. We analyzed these measurements by microenvironment. Indoor-outdoor ratios (I/O) using the home indoor PM2.5 values were calculated in order to assess the air filtration capacity at home in light of increasing outdoor PM2.5 post-intervention. To quantify the effect of intervention on home indoor PM2.5, we conducted a meta-analysis of the results of dwelling-by-dwelling regression of indoor-on-outdoor (I/O) PM2.5 concentrations. On average, adding high-capacity APs and home sealing led to a 15% decrease in PM2.5 measured at home, excluding cooking periods, with a mean (standard deviation) of 7.5 (6.4) μg m−3 pre- to 6.4 (8.1) μg m−3 post-intervention despite a 57% increase in outdoor PM2.5, from 43.8 (30.8) μg m−3 pre- to 68.9 (40.7) μg m−3 post-intervention. Overall mean personal exposure fell by 36% from 15.2 (10.6) μg m−3 to 9.8 (8.7) μg m−3. I/O ratios decreased as outdoor PM2.5 strata increased; when outdoor PM2.5 < 25 μg m−3 the I/O decreased from 0.38 pre- to 0.12 post-intervention and when outdoor PM2.5 was 101–200 μg m−3 the I/O decreased from 0.12 pre- to 0.07 post-intervention. The mean regression slope of indoor-on-outdoor PM2.5 decreased from 0.13 (95% CI 0.09, 0.17) in pre-intervention dwellings to 0.07 (0.04, 0.10) post-intervention. I/O ratios showed a weak negative (not statistically significant) inverse association with air changes per hour at home. In the high pollution environment of Kathmandu, APs with home sealing provide substantial protection against ambient PM2.5 in the home environment, including during periods when outdoor PM2.5 concentration was above 100 μg m−3.","PeriodicalId":72938,"journal":{"name":"Environmental research, health : ERH","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Impact of mitigation measures to improve home indoor air quality in Kathmandu, Nepal\",\"authors\":\"L. Edwards, P. Wilkinson, G. Rutter, Leslie Iverson, A. Milojevic\",\"doi\":\"10.1088/2752-5309/acb663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Air purifiers (APs) and home sealing are interventions used to help protect U.S. diplomats against particle pollution in the home when working in polluted cities. We investigated the effect of these interventions on home indoor and personal PM2.5 exposure in Kathmandu, Nepal. Twenty-one participants underwent repeated 48 hour personal monitoring before and after intervention. We analyzed these measurements by microenvironment. Indoor-outdoor ratios (I/O) using the home indoor PM2.5 values were calculated in order to assess the air filtration capacity at home in light of increasing outdoor PM2.5 post-intervention. To quantify the effect of intervention on home indoor PM2.5, we conducted a meta-analysis of the results of dwelling-by-dwelling regression of indoor-on-outdoor (I/O) PM2.5 concentrations. On average, adding high-capacity APs and home sealing led to a 15% decrease in PM2.5 measured at home, excluding cooking periods, with a mean (standard deviation) of 7.5 (6.4) μg m−3 pre- to 6.4 (8.1) μg m−3 post-intervention despite a 57% increase in outdoor PM2.5, from 43.8 (30.8) μg m−3 pre- to 68.9 (40.7) μg m−3 post-intervention. Overall mean personal exposure fell by 36% from 15.2 (10.6) μg m−3 to 9.8 (8.7) μg m−3. I/O ratios decreased as outdoor PM2.5 strata increased; when outdoor PM2.5 < 25 μg m−3 the I/O decreased from 0.38 pre- to 0.12 post-intervention and when outdoor PM2.5 was 101–200 μg m−3 the I/O decreased from 0.12 pre- to 0.07 post-intervention. The mean regression slope of indoor-on-outdoor PM2.5 decreased from 0.13 (95% CI 0.09, 0.17) in pre-intervention dwellings to 0.07 (0.04, 0.10) post-intervention. I/O ratios showed a weak negative (not statistically significant) inverse association with air changes per hour at home. In the high pollution environment of Kathmandu, APs with home sealing provide substantial protection against ambient PM2.5 in the home environment, including during periods when outdoor PM2.5 concentration was above 100 μg m−3.\",\"PeriodicalId\":72938,\"journal\":{\"name\":\"Environmental research, health : ERH\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental research, health : ERH\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2752-5309/acb663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental research, health : ERH","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2752-5309/acb663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

空气净化器(AP)和家庭密封是用于保护美国外交官在污染城市工作时免受家中颗粒物污染的干预措施。我们调查了这些干预措施对尼泊尔加德满都家庭室内和个人PM2.5暴露的影响。21名参与者在干预前后接受了48小时的反复个人监测。我们通过微环境分析了这些测量结果。根据干预后室外PM2.5的增加,使用家庭室内PM2.5值计算室内外比(I/O),以评估家庭的空气过滤能力。为了量化干预对家庭室内PM2.5的影响,我们对室内外(I/O)PM2.5浓度逐户回归的结果进行了荟萃分析。平均而言,添加高容量AP和家庭密封导致家中测得的PM2.5(不包括烹饪时间)下降15%,干预前的平均值(标准差)为7.5(6.4)μg m−3,干预后为6.4(8.1)μg m-3,尽管室外PM2.5增加了57%,从干预前的43.8(30.8)微克m−3增加到干预后的68.9(40.7)微克m–3。总体平均个人暴露量下降了36%,从15.2(10.6)μg m−3降至9.8(8.7)μg m-3。I/O比率随着室外PM2.5层的增加而降低;当室外PM2.5<25μg m−3时,I/O从干预前的0.38下降到干预后的0.12,当室外PM2.5为101–200μg m–3时,I/O从干预前降至干预后的0.07。室内外PM2.5的平均回归斜率从干预前住宅的0.13(95%CI 0.090.17)降至干预后的0.07(0.040.10)。I/O比率显示,与家中每小时的空气变化呈微弱的负相关(无统计学意义)。在加德满都的高污染环境中,带家庭密封的AP为家庭环境中的环境PM2.5提供了实质性的保护,包括在室外PM2.5浓度超过100μg m−3的时期。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of mitigation measures to improve home indoor air quality in Kathmandu, Nepal
Air purifiers (APs) and home sealing are interventions used to help protect U.S. diplomats against particle pollution in the home when working in polluted cities. We investigated the effect of these interventions on home indoor and personal PM2.5 exposure in Kathmandu, Nepal. Twenty-one participants underwent repeated 48 hour personal monitoring before and after intervention. We analyzed these measurements by microenvironment. Indoor-outdoor ratios (I/O) using the home indoor PM2.5 values were calculated in order to assess the air filtration capacity at home in light of increasing outdoor PM2.5 post-intervention. To quantify the effect of intervention on home indoor PM2.5, we conducted a meta-analysis of the results of dwelling-by-dwelling regression of indoor-on-outdoor (I/O) PM2.5 concentrations. On average, adding high-capacity APs and home sealing led to a 15% decrease in PM2.5 measured at home, excluding cooking periods, with a mean (standard deviation) of 7.5 (6.4) μg m−3 pre- to 6.4 (8.1) μg m−3 post-intervention despite a 57% increase in outdoor PM2.5, from 43.8 (30.8) μg m−3 pre- to 68.9 (40.7) μg m−3 post-intervention. Overall mean personal exposure fell by 36% from 15.2 (10.6) μg m−3 to 9.8 (8.7) μg m−3. I/O ratios decreased as outdoor PM2.5 strata increased; when outdoor PM2.5 < 25 μg m−3 the I/O decreased from 0.38 pre- to 0.12 post-intervention and when outdoor PM2.5 was 101–200 μg m−3 the I/O decreased from 0.12 pre- to 0.07 post-intervention. The mean regression slope of indoor-on-outdoor PM2.5 decreased from 0.13 (95% CI 0.09, 0.17) in pre-intervention dwellings to 0.07 (0.04, 0.10) post-intervention. I/O ratios showed a weak negative (not statistically significant) inverse association with air changes per hour at home. In the high pollution environment of Kathmandu, APs with home sealing provide substantial protection against ambient PM2.5 in the home environment, including during periods when outdoor PM2.5 concentration was above 100 μg m−3.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信