Cristina El Mahdy, S. Popescu, Anamaria Petrean, C. Borda
{"title":"通过消毒过程、氯化和紫外线对水中细菌负荷的评估","authors":"Cristina El Mahdy, S. Popescu, Anamaria Petrean, C. Borda","doi":"10.15835/BUASVMCN-ASB:2018.0013","DOIUrl":null,"url":null,"abstract":"The purpose of the research was to evaluate the degree of reduction of the bacterial load of water using as chemical disinfectant chloramine T 1% (ChT1%) and physical disinfection using UV at a wavelength of 253.93 μm, 30 minutes exposure time. The results of the research show a more significant reduction of TNG/ml of water in samples subjected to exposure to UV, but in this case the decrease is affected by the turbidity of the water.","PeriodicalId":9587,"journal":{"name":"Bulletin of University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca. Animal Science and Biotechnologies","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Bacterial Water Load, Through Disinfection Processes, Chlorination and Ultraviolet\",\"authors\":\"Cristina El Mahdy, S. Popescu, Anamaria Petrean, C. Borda\",\"doi\":\"10.15835/BUASVMCN-ASB:2018.0013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of the research was to evaluate the degree of reduction of the bacterial load of water using as chemical disinfectant chloramine T 1% (ChT1%) and physical disinfection using UV at a wavelength of 253.93 μm, 30 minutes exposure time. The results of the research show a more significant reduction of TNG/ml of water in samples subjected to exposure to UV, but in this case the decrease is affected by the turbidity of the water.\",\"PeriodicalId\":9587,\"journal\":{\"name\":\"Bulletin of University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca. Animal Science and Biotechnologies\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca. Animal Science and Biotechnologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15835/BUASVMCN-ASB:2018.0013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca. Animal Science and Biotechnologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15835/BUASVMCN-ASB:2018.0013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Assessment of Bacterial Water Load, Through Disinfection Processes, Chlorination and Ultraviolet
The purpose of the research was to evaluate the degree of reduction of the bacterial load of water using as chemical disinfectant chloramine T 1% (ChT1%) and physical disinfection using UV at a wavelength of 253.93 μm, 30 minutes exposure time. The results of the research show a more significant reduction of TNG/ml of water in samples subjected to exposure to UV, but in this case the decrease is affected by the turbidity of the water.