Stryker手部电镀系统治疗手部和手指骨折

Q1 Medicine
C. Biehl, S. Stötzel, Lydia Schock, G. Szalay, C. Heiss
{"title":"Stryker手部电镀系统治疗手部和手指骨折","authors":"C. Biehl, S. Stötzel, Lydia Schock, G. Szalay, C. Heiss","doi":"10.3205/000305","DOIUrl":null,"url":null,"abstract":"Objectives: 10% of all fractures occur in the fingers and metacarpal region. Early mobilization with preservation of grip function is the goal of any therapy for these injuries. Osteosyntheses with plates are used in complex fractures that do not allow any other treatment. The aim of this retrospective study was to evaluate the performance and safety of the Stryker Hand System. Patients and methods: Between 2010 and 2019, 190 patients underwent surgical treatment with plates for fractures of the fingers and metacarpal region. Of these, 140 operations could be analyzed according to the inclusion criteria based on clinical and radiological parameters. Results: Three-quarters of the patients were male. The mean age at the time of surgery was 39.3±16 years. Falling was the leading cause for hand fractures, and the most common were fractures of the shaft (>52%). More than 15% were complex hand injuries with more than one fractured finger. The majority of patients were healthy non-smokers without systemic diseases and relevant medical history. Conclusion: The Stryker Finger Plates are safe implants with good results that are consistent with those reported in the literature. The trend is also toward stable-angle implants for fracture treatment of the finger, in order to enable the earliest possible functional, safe mobilization. Level of Evidence: Level: IV; outcome-study, retrospective","PeriodicalId":39243,"journal":{"name":"GMS German Medical Science","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Treatment of hand and finger fractures with the Stryker Hand Plating System\",\"authors\":\"C. Biehl, S. Stötzel, Lydia Schock, G. Szalay, C. Heiss\",\"doi\":\"10.3205/000305\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives: 10% of all fractures occur in the fingers and metacarpal region. Early mobilization with preservation of grip function is the goal of any therapy for these injuries. Osteosyntheses with plates are used in complex fractures that do not allow any other treatment. The aim of this retrospective study was to evaluate the performance and safety of the Stryker Hand System. Patients and methods: Between 2010 and 2019, 190 patients underwent surgical treatment with plates for fractures of the fingers and metacarpal region. Of these, 140 operations could be analyzed according to the inclusion criteria based on clinical and radiological parameters. Results: Three-quarters of the patients were male. The mean age at the time of surgery was 39.3±16 years. Falling was the leading cause for hand fractures, and the most common were fractures of the shaft (>52%). More than 15% were complex hand injuries with more than one fractured finger. The majority of patients were healthy non-smokers without systemic diseases and relevant medical history. Conclusion: The Stryker Finger Plates are safe implants with good results that are consistent with those reported in the literature. The trend is also toward stable-angle implants for fracture treatment of the finger, in order to enable the earliest possible functional, safe mobilization. Level of Evidence: Level: IV; outcome-study, retrospective\",\"PeriodicalId\":39243,\"journal\":{\"name\":\"GMS German Medical Science\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"GMS German Medical Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3205/000305\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"GMS German Medical Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3205/000305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:10%的骨折发生在手指和掌骨区。早期活动和保持握力功能是任何治疗这些损伤的目标。带钢板的骨融合术用于不允许任何其他治疗的复杂骨折。本回顾性研究的目的是评估Stryker手系统的性能和安全性。患者和方法:2010年至2019年期间,190例患者接受了手指和掌骨骨折钢板手术治疗。其中140例手术可根据临床和放射学参数纳入标准进行分析。结果:四分之三的患者为男性。手术时平均年龄39.3±16岁。跌倒是手部骨折的主要原因,最常见的是手轴骨折(52%)。超过15%是复杂的手部损伤,不止一个手指骨折。大多数患者为健康的非吸烟者,无全身性疾病和相关病史。结论:Stryker指板是一种安全的种植体,其效果与文献报道一致。目前的趋势是稳定角度的植入物用于手指骨折治疗,以便尽早实现功能、安全的活动。证据等级:四级;研究结果,回顾
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Treatment of hand and finger fractures with the Stryker Hand Plating System
Objectives: 10% of all fractures occur in the fingers and metacarpal region. Early mobilization with preservation of grip function is the goal of any therapy for these injuries. Osteosyntheses with plates are used in complex fractures that do not allow any other treatment. The aim of this retrospective study was to evaluate the performance and safety of the Stryker Hand System. Patients and methods: Between 2010 and 2019, 190 patients underwent surgical treatment with plates for fractures of the fingers and metacarpal region. Of these, 140 operations could be analyzed according to the inclusion criteria based on clinical and radiological parameters. Results: Three-quarters of the patients were male. The mean age at the time of surgery was 39.3±16 years. Falling was the leading cause for hand fractures, and the most common were fractures of the shaft (>52%). More than 15% were complex hand injuries with more than one fractured finger. The majority of patients were healthy non-smokers without systemic diseases and relevant medical history. Conclusion: The Stryker Finger Plates are safe implants with good results that are consistent with those reported in the literature. The trend is also toward stable-angle implants for fracture treatment of the finger, in order to enable the earliest possible functional, safe mobilization. Level of Evidence: Level: IV; outcome-study, retrospective
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
GMS German Medical Science
GMS German Medical Science Medicine-Medicine (all)
CiteScore
6.30
自引率
0.00%
发文量
10
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信