{"title":"用于地震预警系统测试的振动台设计","authors":"Elena Serea, C. Donciu","doi":"10.3390/designs7030072","DOIUrl":null,"url":null,"abstract":"The unpredictability in time of seismic activities and the dependence of tectonic movements on a multitude of factors challenges specialists to identify the most accurate related methods to avoid catastrophes associated with hazards. Early warning systems are critical in reducing negative effects in the case of an earthquake with a magnitude above 5 MW. Their precision is all the better as they corroborate and transmit more information collected from the regional or on-site sensory nodes to a central unit that discloses events and estimates the epicentral location, earthquake magnitude, or ground shaking amplitude. The shaking table is the proper instrument for evaluating an early warning systems’ dynamic response and performance under specific vibration conditions. To this issue, the paper presents a laboratory single-axis shaking table with a small-scale, low-cost design and an accurate displacement control. Experiments based on a suite of 12 real earthquakes provided results with very small errors related to similar models, bearing out the designed shaking table is suitable for early earthquake warning system response testing for high magnitude earthquakes.","PeriodicalId":53150,"journal":{"name":"Designs","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shaking Table Design for Testing Earthquake Early Warning Systems\",\"authors\":\"Elena Serea, C. Donciu\",\"doi\":\"10.3390/designs7030072\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The unpredictability in time of seismic activities and the dependence of tectonic movements on a multitude of factors challenges specialists to identify the most accurate related methods to avoid catastrophes associated with hazards. Early warning systems are critical in reducing negative effects in the case of an earthquake with a magnitude above 5 MW. Their precision is all the better as they corroborate and transmit more information collected from the regional or on-site sensory nodes to a central unit that discloses events and estimates the epicentral location, earthquake magnitude, or ground shaking amplitude. The shaking table is the proper instrument for evaluating an early warning systems’ dynamic response and performance under specific vibration conditions. To this issue, the paper presents a laboratory single-axis shaking table with a small-scale, low-cost design and an accurate displacement control. Experiments based on a suite of 12 real earthquakes provided results with very small errors related to similar models, bearing out the designed shaking table is suitable for early earthquake warning system response testing for high magnitude earthquakes.\",\"PeriodicalId\":53150,\"journal\":{\"name\":\"Designs\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Designs\",\"FirstCategoryId\":\"1094\",\"ListUrlMain\":\"https://doi.org/10.3390/designs7030072\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Designs","FirstCategoryId":"1094","ListUrlMain":"https://doi.org/10.3390/designs7030072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
Shaking Table Design for Testing Earthquake Early Warning Systems
The unpredictability in time of seismic activities and the dependence of tectonic movements on a multitude of factors challenges specialists to identify the most accurate related methods to avoid catastrophes associated with hazards. Early warning systems are critical in reducing negative effects in the case of an earthquake with a magnitude above 5 MW. Their precision is all the better as they corroborate and transmit more information collected from the regional or on-site sensory nodes to a central unit that discloses events and estimates the epicentral location, earthquake magnitude, or ground shaking amplitude. The shaking table is the proper instrument for evaluating an early warning systems’ dynamic response and performance under specific vibration conditions. To this issue, the paper presents a laboratory single-axis shaking table with a small-scale, low-cost design and an accurate displacement control. Experiments based on a suite of 12 real earthquakes provided results with very small errors related to similar models, bearing out the designed shaking table is suitable for early earthquake warning system response testing for high magnitude earthquakes.