调整分流器后,人工耳蜗植入术后气腹消失

IF 0.3 Q4 OTORHINOLARYNGOLOGY
Karin Hallin, Fredrik Stillesjö, J. Sundblom, N. Danckwardt-Lillieström
{"title":"调整分流器后,人工耳蜗植入术后气腹消失","authors":"Karin Hallin, Fredrik Stillesjö, J. Sundblom, N. Danckwardt-Lillieström","doi":"10.1080/23772484.2020.1838906","DOIUrl":null,"url":null,"abstract":"Abstract We present a case of a male with a history of repeated surgeries for a cerebellar astrocytoma, leading to profound deafness and facial paresis on the left side. A ventriculoperitoneal (VP) shunt was inserted to manage hydrocephalus. At the age of 46 the hearing suddenly disappeared on the right side, where he received a cochlear implant (CI). At implant activation, impedances showed atypical high values. One month later impedance levels had further increased and the patient had no benefit from the CI. A computed tomography (CT) scan suggested air in the cochlea (pneumolabyrinth). The shunt was adjusted to elevate the cerebrospinal fluid (CSF) pressure and the pressure in the perilymph to prevent air from entering the cochlea via the round window. One year after activation the electrode impedances were normal and the hearing outcome from the implant was successful.","PeriodicalId":40723,"journal":{"name":"Acta Oto-Laryngologica Case Reports","volume":"5 1","pages":"81 - 85"},"PeriodicalIF":0.3000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23772484.2020.1838906","citationCount":"1","resultStr":"{\"title\":\"Pneumolabyrinth following cochlear implantation resolved after shunt adjustment\",\"authors\":\"Karin Hallin, Fredrik Stillesjö, J. Sundblom, N. Danckwardt-Lillieström\",\"doi\":\"10.1080/23772484.2020.1838906\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract We present a case of a male with a history of repeated surgeries for a cerebellar astrocytoma, leading to profound deafness and facial paresis on the left side. A ventriculoperitoneal (VP) shunt was inserted to manage hydrocephalus. At the age of 46 the hearing suddenly disappeared on the right side, where he received a cochlear implant (CI). At implant activation, impedances showed atypical high values. One month later impedance levels had further increased and the patient had no benefit from the CI. A computed tomography (CT) scan suggested air in the cochlea (pneumolabyrinth). The shunt was adjusted to elevate the cerebrospinal fluid (CSF) pressure and the pressure in the perilymph to prevent air from entering the cochlea via the round window. One year after activation the electrode impedances were normal and the hearing outcome from the implant was successful.\",\"PeriodicalId\":40723,\"journal\":{\"name\":\"Acta Oto-Laryngologica Case Reports\",\"volume\":\"5 1\",\"pages\":\"81 - 85\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/23772484.2020.1838906\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Oto-Laryngologica Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/23772484.2020.1838906\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Oto-Laryngologica Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/23772484.2020.1838906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

摘要:我们提出一个病例的男性与小脑星形细胞瘤的反复手术的历史,导致深度耳聋和面部轻瘫的左侧。脑室-腹膜(VP)分流治疗脑积水。46岁时,他的右侧听力突然消失,接受了人工耳蜗(CI)。在植入物激活时,阻抗显示非典型的高值。一个月后,阻抗水平进一步升高,患者没有从CI中获益。计算机断层扫描(CT)提示耳蜗内有空气(气迷宫)。调整分流器以提高脑脊液(CSF)压力和淋巴管周围压力,防止空气通过圆窗进入耳蜗。激活一年后,电极阻抗正常,植入的听力结果是成功的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pneumolabyrinth following cochlear implantation resolved after shunt adjustment
Abstract We present a case of a male with a history of repeated surgeries for a cerebellar astrocytoma, leading to profound deafness and facial paresis on the left side. A ventriculoperitoneal (VP) shunt was inserted to manage hydrocephalus. At the age of 46 the hearing suddenly disappeared on the right side, where he received a cochlear implant (CI). At implant activation, impedances showed atypical high values. One month later impedance levels had further increased and the patient had no benefit from the CI. A computed tomography (CT) scan suggested air in the cochlea (pneumolabyrinth). The shunt was adjusted to elevate the cerebrospinal fluid (CSF) pressure and the pressure in the perilymph to prevent air from entering the cochlea via the round window. One year after activation the electrode impedances were normal and the hearing outcome from the implant was successful.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
9
审稿时长
29 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信