12导联心电图——临时心脏起搏管理的宝贵工具

IF 0.2 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
S. H. Naqvi
{"title":"12导联心电图——临时心脏起搏管理的宝贵工具","authors":"S. H. Naqvi","doi":"10.47144/phj.v56i1.2376","DOIUrl":null,"url":null,"abstract":"Inadvertent malposition of pacing leads is a recognized complication of temporary cardiac pacing procedure, which can be fatal particularly if lead placement is in the left ventricular (LV) cavity because of the risk of thromboembolic events.1 Malposition leads can be either due to unrecognized congenital heart defects including atrial or ventricular septal defects, patent foramen ovale or due to iatrogenic perforation of interventricular septum but sometimes it may be due to faulty insertion via trans-arterial instead of trans-venous access.2\n \nReferences\n\nGupta S, Annamalaisamy R, Coupe M. Misplacement of temporary pacing wire into the left ventricle via an anomalous vein. Hellenic J Cardiol. 2010;51(2):175-7.\nGarg N, Moorthy N. Inadvertent temporary pacemaker lead placement in aortic sinus. Heart views: the official journal of the Gulf Heart Association. 2013;14(4):182.\n","PeriodicalId":42273,"journal":{"name":"Pakistan Heart Journal","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"12-Lead Electrocardiogram - A Valuable Tool in Temporary Cardiac Pacing Management\",\"authors\":\"S. H. Naqvi\",\"doi\":\"10.47144/phj.v56i1.2376\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inadvertent malposition of pacing leads is a recognized complication of temporary cardiac pacing procedure, which can be fatal particularly if lead placement is in the left ventricular (LV) cavity because of the risk of thromboembolic events.1 Malposition leads can be either due to unrecognized congenital heart defects including atrial or ventricular septal defects, patent foramen ovale or due to iatrogenic perforation of interventricular septum but sometimes it may be due to faulty insertion via trans-arterial instead of trans-venous access.2\\n \\nReferences\\n\\nGupta S, Annamalaisamy R, Coupe M. Misplacement of temporary pacing wire into the left ventricle via an anomalous vein. Hellenic J Cardiol. 2010;51(2):175-7.\\nGarg N, Moorthy N. Inadvertent temporary pacemaker lead placement in aortic sinus. Heart views: the official journal of the Gulf Heart Association. 2013;14(4):182.\\n\",\"PeriodicalId\":42273,\"journal\":{\"name\":\"Pakistan Heart Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pakistan Heart Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47144/phj.v56i1.2376\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pakistan Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47144/phj.v56i1.2376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

起搏导线的意外错位是临时心脏起搏过程中公认的并发症,这可能是致命的,特别是如果导线放置在左心室(LV)腔中,因为存在血栓栓塞事件的风险。1错位导线可能是由于未识别的先天性心脏缺陷,包括心房或室间隔缺陷,卵圆孔未闭或室间隔医源性穿孔,但有时可能是由于经动脉而非经静脉的错误插入。2参考文献Gupta S,Annamalaisamy R,Coupe M.通过异常静脉将临时起搏导线错误插入左心室。Hellenic J Cardiol。2010年;51(2):175-7.Garg N,Moorthy N。主动脉窦内意外放置临时起搏器导线。心脏观点:海湾心脏协会的官方期刊。2013年;14(4):182。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
12-Lead Electrocardiogram - A Valuable Tool in Temporary Cardiac Pacing Management
Inadvertent malposition of pacing leads is a recognized complication of temporary cardiac pacing procedure, which can be fatal particularly if lead placement is in the left ventricular (LV) cavity because of the risk of thromboembolic events.1 Malposition leads can be either due to unrecognized congenital heart defects including atrial or ventricular septal defects, patent foramen ovale or due to iatrogenic perforation of interventricular septum but sometimes it may be due to faulty insertion via trans-arterial instead of trans-venous access.2   References Gupta S, Annamalaisamy R, Coupe M. Misplacement of temporary pacing wire into the left ventricle via an anomalous vein. Hellenic J Cardiol. 2010;51(2):175-7. Garg N, Moorthy N. Inadvertent temporary pacemaker lead placement in aortic sinus. Heart views: the official journal of the Gulf Heart Association. 2013;14(4):182.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pakistan Heart Journal
Pakistan Heart Journal CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
0.20
自引率
0.00%
发文量
64
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信