{"title":"三重GEM探测器辐射剂量测定","authors":"Andrea Velasquez, Héctor F. Castro","doi":"10.15446/mo.n66.104505","DOIUrl":null,"url":null,"abstract":"We studied the properties of the gaseous detector triple-GEM (triple Gas Electron Multiplier) as a dosimeter with different ionizing radiation sources used in medical applications. The detector was calibrated in energy with an Iron-55 radioactive source. We measured doses of radiation from different radioactive sources as well as from a medical portable X-ray machine, and compared them to reference values. The detector presents a linear dependence between radiation intensity and measured dose. A calibration factor of 1.13x104 was found, independently of the radiation source. These results allow us to conclude that the triple-GEM detector has the potential to be used as a dosimeter in medical applications.","PeriodicalId":42463,"journal":{"name":"MOMENTO-Revista de Fisica","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radiation dosimetry with a Triple-GEM detector\",\"authors\":\"Andrea Velasquez, Héctor F. Castro\",\"doi\":\"10.15446/mo.n66.104505\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We studied the properties of the gaseous detector triple-GEM (triple Gas Electron Multiplier) as a dosimeter with different ionizing radiation sources used in medical applications. The detector was calibrated in energy with an Iron-55 radioactive source. We measured doses of radiation from different radioactive sources as well as from a medical portable X-ray machine, and compared them to reference values. The detector presents a linear dependence between radiation intensity and measured dose. A calibration factor of 1.13x104 was found, independently of the radiation source. These results allow us to conclude that the triple-GEM detector has the potential to be used as a dosimeter in medical applications.\",\"PeriodicalId\":42463,\"journal\":{\"name\":\"MOMENTO-Revista de Fisica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MOMENTO-Revista de Fisica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15446/mo.n66.104505\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MOMENTO-Revista de Fisica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15446/mo.n66.104505","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
We studied the properties of the gaseous detector triple-GEM (triple Gas Electron Multiplier) as a dosimeter with different ionizing radiation sources used in medical applications. The detector was calibrated in energy with an Iron-55 radioactive source. We measured doses of radiation from different radioactive sources as well as from a medical portable X-ray machine, and compared them to reference values. The detector presents a linear dependence between radiation intensity and measured dose. A calibration factor of 1.13x104 was found, independently of the radiation source. These results allow us to conclude that the triple-GEM detector has the potential to be used as a dosimeter in medical applications.