{"title":"犬眼内淋巴瘤——超声造影和ARFI弹性成像结果","authors":"G. M. Madruga, Igor Cezar Kniphoff da Cruz, R. K. Carneiro, Marcus Antônio Rossi Feliciano, Marjury Cristina Maronez, R. Uscategui, Thais Guimarães Morato Abreu, E. Perlmann","doi":"10.22456/1679-9216.121902","DOIUrl":null,"url":null,"abstract":"Background: Ocular lymphoma can affect the iris, conjunctiva, choroid, and retina and is mostly associated with multicentric disease. Elastography is an ultrasound technique that provides noninvasive, pain-free assessment of tissue stiffness. It has the ability to assess subtle changes throughout the organ as well as focal lesions. Microbubble contrast ultrasound enables the detection of incipient vascular flows, which are difficult to detect using traditional ultrasound methods. This study aimed to describe acoustic radiation force impulse (ARFI) elastography and microbubble contrast ultrasound findings in the eyes of two dogs diagnosed with intraocular T-cell lymphoma.\nCases: Case 1. Physical examination revealed an exophytic mass in the left eye. Schirmer test revealed a secretion of 22 mm/min. Negative threat reflex, glare, direct pupillary light reflex, and consensual response were also noted. Biomicroscopy revealed hyperplasia of the third eyelid, overlapping with the affected eye. When the membrane was removed, moderate conjunctival hyperemia, mucoid secretion, and buphthalmia were observed. In addition, significant corneal edema was present, making it impossible to visualize the anterior chamber and perform fundus examination. The intraocular pressure, as measured with a rebound tonometer, was 39 mmHg. B-mode ultrasonography identified amorphous, hyperechoic, and heterogeneous structures throughout the anterior chamber, iris, and ciliary body. The elastogram showed that the mass had greenish tones and intermediate stiffness, and the mean SWV of the ciliary body and iris was 2 m/s. Contrast-enhanced ultrasound (CEUS) revealed vascularization of the neoformation region, with wash-in, peak, and wash-out values of 9.89 s, 24.56 s, and 107.87 s, respectively. Case 2. On physical examination, a change in the shape of the right pupil was observed. Schirmer test revealed a secretion of 20 mm/min, with negative threat, glare, and pupillary reflexes to direct and consensual light. Biomicroscopy revealed neoformation from 7 am to 11 am in the sclera, retina, and choroid complex, concomitant with dyscoria and conjunctival hyperemia. The intraocular pressure, as measured by rebound tonometry, was 33 mmHg. Fundoscopy revealed a mass in the temporal region and focal retinal detachment. No changes were observed in the contralateral eye. B-mode ultrasound revealed an increase in volume in the temporal region of the iris, ciliary body, and choroid with diffuse heterogeneity and partial retinal detachment. Elastographic examination revealed shades of green and yellow compatible with increased tissue stiffness. On quantitative examination, the mean SWVs of the ciliary body and iris were 3.14 m/s. On CEUS, the neoformation region presented wash-in, peak, and wash-out values of 8.67 s, 22.33 s, and 80.20 s.\nDiscussion: B-mode ultrasonography established the tumor extent and evaluated echogenicity, verifying the involved ocular structures. The examination played an important role in the diagnosis as well as clinical management. ARFI elastography can detect small tissue changes, helping to define nodules and masses more reliably, in addition to allowing the verification of tissue stiffness. In both dogs, it was possible to verify that the masses presented greater rigidity than the adjacent tissues both qualitatively and quantitatively. In previous studies, it was found that cutaneous and breast lymphomas in humans were more rigid than adjacent tissues on elastography. This increase in rigidity and heterogeneity observed on elastograms can be explained by the extramedullary interactions of the matrix in T-cell lymphomas. Tumor growth is dependent on the blood supply, which was evaluated using CEUS in these cases. Furthermore, the ciliary body contrast filling times were longer than those described in normal dogs.\nKeywords: eye, surgery, diagnostic imaging, pain, veterinary ophthalmology, neoplasia.\nTítulo: Linfoma intraocular em cães - achados da ultrassonografia contrastada e elastografia  ARFI\nDescritores: olho, cirurgia, diagnóstico por imagem, dor, oftlamologia veterinária, neoplasia.","PeriodicalId":7182,"journal":{"name":"Acta Scientiae Veterinariae","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2022-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intraocular Lymphoma in Dogs - Findings of Contrast Enhanced Ultrasound and ARFI Elastography\",\"authors\":\"G. M. Madruga, Igor Cezar Kniphoff da Cruz, R. K. Carneiro, Marcus Antônio Rossi Feliciano, Marjury Cristina Maronez, R. Uscategui, Thais Guimarães Morato Abreu, E. Perlmann\",\"doi\":\"10.22456/1679-9216.121902\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Ocular lymphoma can affect the iris, conjunctiva, choroid, and retina and is mostly associated with multicentric disease. Elastography is an ultrasound technique that provides noninvasive, pain-free assessment of tissue stiffness. It has the ability to assess subtle changes throughout the organ as well as focal lesions. Microbubble contrast ultrasound enables the detection of incipient vascular flows, which are difficult to detect using traditional ultrasound methods. This study aimed to describe acoustic radiation force impulse (ARFI) elastography and microbubble contrast ultrasound findings in the eyes of two dogs diagnosed with intraocular T-cell lymphoma.\\nCases: Case 1. Physical examination revealed an exophytic mass in the left eye. Schirmer test revealed a secretion of 22 mm/min. Negative threat reflex, glare, direct pupillary light reflex, and consensual response were also noted. Biomicroscopy revealed hyperplasia of the third eyelid, overlapping with the affected eye. When the membrane was removed, moderate conjunctival hyperemia, mucoid secretion, and buphthalmia were observed. In addition, significant corneal edema was present, making it impossible to visualize the anterior chamber and perform fundus examination. The intraocular pressure, as measured with a rebound tonometer, was 39 mmHg. B-mode ultrasonography identified amorphous, hyperechoic, and heterogeneous structures throughout the anterior chamber, iris, and ciliary body. The elastogram showed that the mass had greenish tones and intermediate stiffness, and the mean SWV of the ciliary body and iris was 2 m/s. Contrast-enhanced ultrasound (CEUS) revealed vascularization of the neoformation region, with wash-in, peak, and wash-out values of 9.89 s, 24.56 s, and 107.87 s, respectively. Case 2. On physical examination, a change in the shape of the right pupil was observed. Schirmer test revealed a secretion of 20 mm/min, with negative threat, glare, and pupillary reflexes to direct and consensual light. Biomicroscopy revealed neoformation from 7 am to 11 am in the sclera, retina, and choroid complex, concomitant with dyscoria and conjunctival hyperemia. The intraocular pressure, as measured by rebound tonometry, was 33 mmHg. Fundoscopy revealed a mass in the temporal region and focal retinal detachment. No changes were observed in the contralateral eye. B-mode ultrasound revealed an increase in volume in the temporal region of the iris, ciliary body, and choroid with diffuse heterogeneity and partial retinal detachment. Elastographic examination revealed shades of green and yellow compatible with increased tissue stiffness. On quantitative examination, the mean SWVs of the ciliary body and iris were 3.14 m/s. On CEUS, the neoformation region presented wash-in, peak, and wash-out values of 8.67 s, 22.33 s, and 80.20 s.\\nDiscussion: B-mode ultrasonography established the tumor extent and evaluated echogenicity, verifying the involved ocular structures. The examination played an important role in the diagnosis as well as clinical management. ARFI elastography can detect small tissue changes, helping to define nodules and masses more reliably, in addition to allowing the verification of tissue stiffness. In both dogs, it was possible to verify that the masses presented greater rigidity than the adjacent tissues both qualitatively and quantitatively. In previous studies, it was found that cutaneous and breast lymphomas in humans were more rigid than adjacent tissues on elastography. This increase in rigidity and heterogeneity observed on elastograms can be explained by the extramedullary interactions of the matrix in T-cell lymphomas. Tumor growth is dependent on the blood supply, which was evaluated using CEUS in these cases. Furthermore, the ciliary body contrast filling times were longer than those described in normal dogs.\\nKeywords: eye, surgery, diagnostic imaging, pain, veterinary ophthalmology, neoplasia.\\nTítulo: Linfoma intraocular em cães - achados da ultrassonografia contrastada e elastografia  ARFI\\nDescritores: olho, cirurgia, diagnóstico por imagem, dor, oftlamologia veterinária, neoplasia.\",\"PeriodicalId\":7182,\"journal\":{\"name\":\"Acta Scientiae Veterinariae\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Scientiae Veterinariae\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.22456/1679-9216.121902\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Scientiae Veterinariae","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.22456/1679-9216.121902","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景:眼部淋巴瘤可累及虹膜、结膜、脉络膜和视网膜,且多与多中心疾病相关。弹性成像是一种超声技术,提供无创、无痛的组织刚度评估。它有能力评估整个器官的细微变化以及局灶性病变。微泡超声造影能够检测到早期血管流动,这是传统超声方法难以检测到的。本研究旨在描述两只被诊断为眼内t细胞淋巴瘤的狗的眼睛的声辐射力脉冲(ARFI)弹性成像和微泡造影剂超声检查结果。案例:案例1。体检发现左眼有外生性肿块。Schirmer试验显示分泌量为22 mm/min。负面威胁反射,眩光,直接瞳孔光反射和共识反应也被注意到。生物显微镜检查显示第三眼睑增生,与患眼重叠。去膜后,观察到中度结膜充血、粘液分泌、眼黄。此外,存在明显的角膜水肿,使得无法看到前房和进行眼底检查。用回弹眼压计测得眼压为39mmhg。b超检查发现无定形、高回声和非均匀结构遍及前房、虹膜和睫状体。弹性图显示,肿块呈偏绿色,刚度中等,纤毛体和虹膜的平均SWV为2 m/s。超声造影显示新生区血管化,洗入值为9.89 s,峰值值为24.56 s,洗出值为107.87 s。例2。在体格检查中,观察到右瞳孔形状的改变。Schirmer试验显示分泌量为20 mm/min,对直射光和自愿光的威胁、眩光和瞳孔反射均为阴性。生物显微镜检查显示,上午7点至11点,巩膜、视网膜和脉络膜复合体出现新生物,并伴有血氧障碍和结膜充血。反跳眼压计测眼压为33 mmHg。眼底镜检查显示颞区肿块和局灶性视网膜脱离。对侧眼未见改变。b超显示虹膜、睫状体和脉络膜颞区体积增加,弥漫性不均一性和部分视网膜脱离。弹性图检查显示绿色和黄色阴影与组织刚度增加相一致。经定量检测,纤毛体和虹膜的平均swv为3.14 m/s。超声造影显示,新生区域的洗入、峰值和洗出值分别为8.67 s、22.33 s和80.20 s。讨论:b超确定肿瘤范围,评价回声性,证实受累的眼部结构。检查在诊断和临床治疗中起着重要的作用。ARFI弹性成像可以检测微小的组织变化,帮助更可靠地定义结节和肿块,此外还可以验证组织刚度。在这两只狗中,有可能在定性和定量上验证肿块比相邻组织表现出更大的刚性。在以往的研究中,发现人类皮肤和乳腺淋巴瘤在弹性成像上比邻近组织更坚硬。在弹性图上观察到的刚性和异质性的增加可以用t细胞淋巴瘤中基质的髓外相互作用来解释。肿瘤生长依赖于血液供应,在这些病例中使用超声造影评估。此外,睫状体对比剂填充时间比正常犬长。关键词:眼,外科,影像诊断,疼痛,兽医眼科,肿瘤。Título:眼内膜瘤 -眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤-眼内膜瘤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intraocular Lymphoma in Dogs - Findings of Contrast Enhanced Ultrasound and ARFI Elastography
Background: Ocular lymphoma can affect the iris, conjunctiva, choroid, and retina and is mostly associated with multicentric disease. Elastography is an ultrasound technique that provides noninvasive, pain-free assessment of tissue stiffness. It has the ability to assess subtle changes throughout the organ as well as focal lesions. Microbubble contrast ultrasound enables the detection of incipient vascular flows, which are difficult to detect using traditional ultrasound methods. This study aimed to describe acoustic radiation force impulse (ARFI) elastography and microbubble contrast ultrasound findings in the eyes of two dogs diagnosed with intraocular T-cell lymphoma. Cases: Case 1. Physical examination revealed an exophytic mass in the left eye. Schirmer test revealed a secretion of 22 mm/min. Negative threat reflex, glare, direct pupillary light reflex, and consensual response were also noted. Biomicroscopy revealed hyperplasia of the third eyelid, overlapping with the affected eye. When the membrane was removed, moderate conjunctival hyperemia, mucoid secretion, and buphthalmia were observed. In addition, significant corneal edema was present, making it impossible to visualize the anterior chamber and perform fundus examination. The intraocular pressure, as measured with a rebound tonometer, was 39 mmHg. B-mode ultrasonography identified amorphous, hyperechoic, and heterogeneous structures throughout the anterior chamber, iris, and ciliary body. The elastogram showed that the mass had greenish tones and intermediate stiffness, and the mean SWV of the ciliary body and iris was 2 m/s. Contrast-enhanced ultrasound (CEUS) revealed vascularization of the neoformation region, with wash-in, peak, and wash-out values of 9.89 s, 24.56 s, and 107.87 s, respectively. Case 2. On physical examination, a change in the shape of the right pupil was observed. Schirmer test revealed a secretion of 20 mm/min, with negative threat, glare, and pupillary reflexes to direct and consensual light. Biomicroscopy revealed neoformation from 7 am to 11 am in the sclera, retina, and choroid complex, concomitant with dyscoria and conjunctival hyperemia. The intraocular pressure, as measured by rebound tonometry, was 33 mmHg. Fundoscopy revealed a mass in the temporal region and focal retinal detachment. No changes were observed in the contralateral eye. B-mode ultrasound revealed an increase in volume in the temporal region of the iris, ciliary body, and choroid with diffuse heterogeneity and partial retinal detachment. Elastographic examination revealed shades of green and yellow compatible with increased tissue stiffness. On quantitative examination, the mean SWVs of the ciliary body and iris were 3.14 m/s. On CEUS, the neoformation region presented wash-in, peak, and wash-out values of 8.67 s, 22.33 s, and 80.20 s. Discussion: B-mode ultrasonography established the tumor extent and evaluated echogenicity, verifying the involved ocular structures. The examination played an important role in the diagnosis as well as clinical management. ARFI elastography can detect small tissue changes, helping to define nodules and masses more reliably, in addition to allowing the verification of tissue stiffness. In both dogs, it was possible to verify that the masses presented greater rigidity than the adjacent tissues both qualitatively and quantitatively. In previous studies, it was found that cutaneous and breast lymphomas in humans were more rigid than adjacent tissues on elastography. This increase in rigidity and heterogeneity observed on elastograms can be explained by the extramedullary interactions of the matrix in T-cell lymphomas. Tumor growth is dependent on the blood supply, which was evaluated using CEUS in these cases. Furthermore, the ciliary body contrast filling times were longer than those described in normal dogs. Keywords: eye, surgery, diagnostic imaging, pain, veterinary ophthalmology, neoplasia. Título: Linfoma intraocular em cães - achados da ultrassonografia contrastada e elastografia  ARFI Descritores: olho, cirurgia, diagnóstico por imagem, dor, oftlamologia veterinária, neoplasia.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Scientiae Veterinariae
Acta Scientiae Veterinariae VETERINARY SCIENCES-
CiteScore
0.40
自引率
0.00%
发文量
75
审稿时长
6-12 weeks
期刊介绍: ASV is concerned with papers dealing with all aspects of disease prevention, clinical and internal medicine, pathology, surgery, epidemiology, immunology, diagnostic and therapeutic procedures, in addition to fundamental research in physiology, biochemistry, immunochemistry, genetics, cell and molecular biology applied to the veterinary field and as an interface with public health. The submission of a manuscript implies that the same work has not been published and is not under consideration for publication elsewhere. The manuscripts should be first submitted online to the Editor. There are no page charges, only a submission fee.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信