%小细胞/%低色细胞比值在小细胞性贫血鉴别诊断中的判别价值

IF 0.6 Q4 HEMATOLOGY
E. Urrechaga
{"title":"%小细胞/%低色细胞比值在小细胞性贫血鉴别诊断中的判别价值","authors":"E. Urrechaga","doi":"10.4081/thal.2020.8388","DOIUrl":null,"url":null,"abstract":"The Mindray 6800 Plus analyzer reports red cells (RBC) extended parameters, which represent the subsets of erythrocytes. We aimed to evaluate the reliability of RBC extended parameters in the differential diagnosis of microcytic anemia. The learning set comprised samples from 250 patients with microcytic anemia mean cell volume <80 fL. MH ratio (%microcytic cells/%hypochromic cells) and other discriminant functions were calculated. Optimal cut offs were established using receiver operator curves. This value was used in the validation set of 135 patients 50 carriers and 85 with mild iron deficiency anemia (IDA). Area under the curve 0.945 (95% confidence interval 0.890 to 0.977), cut off >10 rendered the best Youden index (0.798), sensitivity 93.2%, specificity 86.2%. In the validation set using MH ratio >10, 45 in 50 patients were correctly classified as carriers. All of 40 beta carriers were correctly classified, while the 5 false negatives resulted to be alpha carriers. In the IDA group 5 patients had MH ratio >10 and thus considered carriers, but all of them had Hyper <3%. The combination of MH ratio >10 and %Hyper <3% correctly classified 100% of IDA patients. An algorithm derived from RBC extended parameters provided by the Mindray 6800 Plus analyzer could be a useful tool in the differential diagnosis of microcytic anemia.","PeriodicalId":22261,"journal":{"name":"Thalassemia Reports","volume":"10 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2020-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4081/thal.2020.8388","citationCount":"2","resultStr":"{\"title\":\"Discriminant value of %microcytic cells/%hypochromic cells ratio in the differential diagnosis of microcytic anemia\",\"authors\":\"E. Urrechaga\",\"doi\":\"10.4081/thal.2020.8388\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Mindray 6800 Plus analyzer reports red cells (RBC) extended parameters, which represent the subsets of erythrocytes. We aimed to evaluate the reliability of RBC extended parameters in the differential diagnosis of microcytic anemia. The learning set comprised samples from 250 patients with microcytic anemia mean cell volume <80 fL. MH ratio (%microcytic cells/%hypochromic cells) and other discriminant functions were calculated. Optimal cut offs were established using receiver operator curves. This value was used in the validation set of 135 patients 50 carriers and 85 with mild iron deficiency anemia (IDA). Area under the curve 0.945 (95% confidence interval 0.890 to 0.977), cut off >10 rendered the best Youden index (0.798), sensitivity 93.2%, specificity 86.2%. In the validation set using MH ratio >10, 45 in 50 patients were correctly classified as carriers. All of 40 beta carriers were correctly classified, while the 5 false negatives resulted to be alpha carriers. In the IDA group 5 patients had MH ratio >10 and thus considered carriers, but all of them had Hyper <3%. The combination of MH ratio >10 and %Hyper <3% correctly classified 100% of IDA patients. An algorithm derived from RBC extended parameters provided by the Mindray 6800 Plus analyzer could be a useful tool in the differential diagnosis of microcytic anemia.\",\"PeriodicalId\":22261,\"journal\":{\"name\":\"Thalassemia Reports\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2020-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4081/thal.2020.8388\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thalassemia Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4081/thal.2020.8388\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thalassemia Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/thal.2020.8388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 2

摘要

迈瑞6800 Plus分析仪报告红细胞(RBC)扩展参数,这些参数代表红细胞的亚群。我们的目的是评估红细胞扩展参数在微细胞性贫血鉴别诊断中的可靠性。该学习集包括250名微细胞性贫血患者的样本,平均细胞体积10呈现出最佳的Youden指数(0.798),敏感性93.2%,特异性86.2%。在MH比率>10的验证集中,50名患者中有45人被正确归类为携带者。所有40个β携带者都被正确分类,而5个假阴性结果是α携带者。在IDA组中,5名患者的MH比率>10,因此被视为携带者,但所有患者的Hyper 10和%Hyper<3%正确分类了100%的IDA患者。从Mindray 6800 Plus分析仪提供的RBC扩展参数导出的算法可能是鉴别诊断微细胞性贫血的有用工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Discriminant value of %microcytic cells/%hypochromic cells ratio in the differential diagnosis of microcytic anemia
The Mindray 6800 Plus analyzer reports red cells (RBC) extended parameters, which represent the subsets of erythrocytes. We aimed to evaluate the reliability of RBC extended parameters in the differential diagnosis of microcytic anemia. The learning set comprised samples from 250 patients with microcytic anemia mean cell volume <80 fL. MH ratio (%microcytic cells/%hypochromic cells) and other discriminant functions were calculated. Optimal cut offs were established using receiver operator curves. This value was used in the validation set of 135 patients 50 carriers and 85 with mild iron deficiency anemia (IDA). Area under the curve 0.945 (95% confidence interval 0.890 to 0.977), cut off >10 rendered the best Youden index (0.798), sensitivity 93.2%, specificity 86.2%. In the validation set using MH ratio >10, 45 in 50 patients were correctly classified as carriers. All of 40 beta carriers were correctly classified, while the 5 false negatives resulted to be alpha carriers. In the IDA group 5 patients had MH ratio >10 and thus considered carriers, but all of them had Hyper <3%. The combination of MH ratio >10 and %Hyper <3% correctly classified 100% of IDA patients. An algorithm derived from RBC extended parameters provided by the Mindray 6800 Plus analyzer could be a useful tool in the differential diagnosis of microcytic anemia.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Thalassemia Reports
Thalassemia Reports HEMATOLOGY-
自引率
0.00%
发文量
17
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信