修正比辛胆酸(BCA)吸光度法分析蛋白质浓度

IF 0.8 Q4 MATERIALS SCIENCE, BIOMATERIALS
Daniel Smith, Elizabeth N. Lemieux, Sutapa Barua
{"title":"修正比辛胆酸(BCA)吸光度法分析蛋白质浓度","authors":"Daniel Smith, Elizabeth N. Lemieux, Sutapa Barua","doi":"10.1142/S1793984418500058","DOIUrl":null,"url":null,"abstract":"Conducting the bicinchoninic acid (BCA) assay directly after a coupling reaction using (1-ethyl-3-(3-dimethylaminopropyl) carbodiimide) (EDC) and [Formula: see text]-hydroxysuccinimide (NHS) chemistry produces significant errors. Here we present a correction for the quantification of gelatin in the supernatant (SN) following gelatin conjugation to polymer microparticles using EDC and NHS chemistry. Following the conjugation reaction, SNs from the gelatin-microparticle formation reaction are treated with BCA assay reagents and quantified for the percentage of unbound gelatin in the solution. NHS was found to interfere with the BCA assay reagents and is dependent on incubation time. It is found that the large concentration (500[Formula: see text][Formula: see text]g/mL) of NHS in the conjugation reaction interferes with the sensitivity of gelatin present in SNs. The interference from NHS requires a careful analysis to distinguish the BCA background absorbance from the sample absorbance. Using an NHS control solution can correct NHS interference and thus decrease the expensive iterations in gelatin quantification and enable accurate analysis of gelatin content. The accuracy of gelatin quantification is further improved by reducing the BCA assay incubation time to approximately 20[Formula: see text]min, compared with the recommended 30[Formula: see text]min. This re-assessment of BCA assay is important to avoid misestimating biases in bioconjugation processes.","PeriodicalId":44929,"journal":{"name":"Nano Life","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1142/S1793984418500058","citationCount":"5","resultStr":"{\"title\":\"Correction in Bicinchoninic Acid (BCA) Absorbance Assay to Analyze Protein Concentration\",\"authors\":\"Daniel Smith, Elizabeth N. Lemieux, Sutapa Barua\",\"doi\":\"10.1142/S1793984418500058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conducting the bicinchoninic acid (BCA) assay directly after a coupling reaction using (1-ethyl-3-(3-dimethylaminopropyl) carbodiimide) (EDC) and [Formula: see text]-hydroxysuccinimide (NHS) chemistry produces significant errors. Here we present a correction for the quantification of gelatin in the supernatant (SN) following gelatin conjugation to polymer microparticles using EDC and NHS chemistry. Following the conjugation reaction, SNs from the gelatin-microparticle formation reaction are treated with BCA assay reagents and quantified for the percentage of unbound gelatin in the solution. NHS was found to interfere with the BCA assay reagents and is dependent on incubation time. It is found that the large concentration (500[Formula: see text][Formula: see text]g/mL) of NHS in the conjugation reaction interferes with the sensitivity of gelatin present in SNs. The interference from NHS requires a careful analysis to distinguish the BCA background absorbance from the sample absorbance. Using an NHS control solution can correct NHS interference and thus decrease the expensive iterations in gelatin quantification and enable accurate analysis of gelatin content. The accuracy of gelatin quantification is further improved by reducing the BCA assay incubation time to approximately 20[Formula: see text]min, compared with the recommended 30[Formula: see text]min. This re-assessment of BCA assay is important to avoid misestimating biases in bioconjugation processes.\",\"PeriodicalId\":44929,\"journal\":{\"name\":\"Nano Life\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1142/S1793984418500058\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nano Life\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/S1793984418500058\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nano Life","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S1793984418500058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 5

摘要

在使用(1-乙基-3-(3-二甲氨基丙基)碳二亚胺(EDC)和[公式:见正文]-羟基琥珀酰亚胺(NHS)化学偶联反应后直接进行bicinchoninic酸(BCA)测定会产生显着误差。在这里,我们提出了明胶定量上清(SN)后明胶偶联到聚合物微粒使用EDC和NHS化学校正。在结合反应之后,用BCA测定试剂处理明胶-微粒形成反应产生的SNs,并定量测定溶液中未结合明胶的百分比。发现NHS干扰BCA测定试剂,并依赖于孵育时间。结果发现,偶联反应中NHS的大浓度(500 g/mL)干扰了SNs中明胶的敏感性。来自NHS的干扰需要仔细分析,以区分BCA背景吸光度与样品吸光度。使用NHS控制解决方案可以纠正NHS干扰,从而减少明胶定量中昂贵的迭代,并能够准确分析明胶含量。与推荐的30分钟相比,将BCA测定的孵育时间减少到大约20分钟,进一步提高了明胶定量的准确性。对BCA检测的重新评估对于避免生物偶联过程中的错误估计偏差很重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Correction in Bicinchoninic Acid (BCA) Absorbance Assay to Analyze Protein Concentration
Conducting the bicinchoninic acid (BCA) assay directly after a coupling reaction using (1-ethyl-3-(3-dimethylaminopropyl) carbodiimide) (EDC) and [Formula: see text]-hydroxysuccinimide (NHS) chemistry produces significant errors. Here we present a correction for the quantification of gelatin in the supernatant (SN) following gelatin conjugation to polymer microparticles using EDC and NHS chemistry. Following the conjugation reaction, SNs from the gelatin-microparticle formation reaction are treated with BCA assay reagents and quantified for the percentage of unbound gelatin in the solution. NHS was found to interfere with the BCA assay reagents and is dependent on incubation time. It is found that the large concentration (500[Formula: see text][Formula: see text]g/mL) of NHS in the conjugation reaction interferes with the sensitivity of gelatin present in SNs. The interference from NHS requires a careful analysis to distinguish the BCA background absorbance from the sample absorbance. Using an NHS control solution can correct NHS interference and thus decrease the expensive iterations in gelatin quantification and enable accurate analysis of gelatin content. The accuracy of gelatin quantification is further improved by reducing the BCA assay incubation time to approximately 20[Formula: see text]min, compared with the recommended 30[Formula: see text]min. This re-assessment of BCA assay is important to avoid misestimating biases in bioconjugation processes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nano Life
Nano Life MATERIALS SCIENCE, BIOMATERIALS-
CiteScore
0.70
自引率
12.50%
发文量
14
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信