皮质发射静脉:骨锚定助听器植入前需要寻找的重要血管

IF 0.2 Q4 OTORHINOLARYNGOLOGY
A. Dahlan, I. Zainon, Z. Yeoh, Mohd Khairi Md Daud
{"title":"皮质发射静脉:骨锚定助听器植入前需要寻找的重要血管","authors":"A. Dahlan, I. Zainon, Z. Yeoh, Mohd Khairi Md Daud","doi":"10.4103/indianjotol.indianjotol_146_21","DOIUrl":null,"url":null,"abstract":"Bone anchored hearing aid (BAHA) is a device that combines a sound processor with a small titanium fixture implanted at the mastoid area. It is indicated for those having conductive hearing loss, especially in those not suitable for hearing aids. Emissary veins are residual connections between intracerebral veins and their extracranial drainage. The vein may be injured at the time of drilling procedure such as during insertion of implant at the mastoid area. We report a case of difficult BAHA surgery after encounter with cortical emissary vein. Mastoid emissary vein is a rare but definite entity which if not diagnosed preoperatively could be a cause of severe hemorrhage intraoperatively.","PeriodicalId":44304,"journal":{"name":"Indian Journal of Otology","volume":"28 1","pages":"91 - 93"},"PeriodicalIF":0.2000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cortical emissary vein: An important vessel to look for before bone anchored hearing aid implantation\",\"authors\":\"A. Dahlan, I. Zainon, Z. Yeoh, Mohd Khairi Md Daud\",\"doi\":\"10.4103/indianjotol.indianjotol_146_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bone anchored hearing aid (BAHA) is a device that combines a sound processor with a small titanium fixture implanted at the mastoid area. It is indicated for those having conductive hearing loss, especially in those not suitable for hearing aids. Emissary veins are residual connections between intracerebral veins and their extracranial drainage. The vein may be injured at the time of drilling procedure such as during insertion of implant at the mastoid area. We report a case of difficult BAHA surgery after encounter with cortical emissary vein. Mastoid emissary vein is a rare but definite entity which if not diagnosed preoperatively could be a cause of severe hemorrhage intraoperatively.\",\"PeriodicalId\":44304,\"journal\":{\"name\":\"Indian Journal of Otology\",\"volume\":\"28 1\",\"pages\":\"91 - 93\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Otology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/indianjotol.indianjotol_146_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/indianjotol.indianjotol_146_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

骨锚助听器(BAHA)是一种将声音处理器与植入乳突区域的小型钛固定装置相结合的设备。它适用于那些有传导性听力损失的人,尤其是那些不适合使用助听器的人。使静脉是脑内静脉与其颅外引流之间的残余连接。静脉可能在钻孔过程中受伤,例如在乳突区域插入植入物期间。我们报告了一例在遇到皮质发射静脉后难以进行BAHA手术的病例。Mastoid发射静脉是一种罕见但明确的实体,如果术前未诊断,可能是术中严重出血的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cortical emissary vein: An important vessel to look for before bone anchored hearing aid implantation
Bone anchored hearing aid (BAHA) is a device that combines a sound processor with a small titanium fixture implanted at the mastoid area. It is indicated for those having conductive hearing loss, especially in those not suitable for hearing aids. Emissary veins are residual connections between intracerebral veins and their extracranial drainage. The vein may be injured at the time of drilling procedure such as during insertion of implant at the mastoid area. We report a case of difficult BAHA surgery after encounter with cortical emissary vein. Mastoid emissary vein is a rare but definite entity which if not diagnosed preoperatively could be a cause of severe hemorrhage intraoperatively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Journal of Otology
Indian Journal of Otology OTORHINOLARYNGOLOGY-
CiteScore
0.40
自引率
0.00%
发文量
21
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信