N. P. Kopylov, D. Fedotkin, E. Sushkina, V.I. Novikova
{"title":"自发泡气体气溶胶泡沫脉冲灭火装置的标准化","authors":"N. P. Kopylov, D. Fedotkin, E. Sushkina, V.I. Novikova","doi":"10.24000/0409-2961-2023-7-16-20","DOIUrl":null,"url":null,"abstract":"Pulse fire extinguishing was actively developing. There is a wide range of impulse fire extinguishing devices on the market. However, existing standards do not cover the entire class of these products. Hence there are problems with their certification. To date, two standards are approved and in force: GOST R 53291—2009 «Fire-fighting equipment. Mobile and portable fire extinguishing devices with high-speed delivery of fire extinguishing agent. General technical requirements. Test methods», and GOST R 53286—2009 «Fire-fighting equipment. Automatic powder fire-extinguishing installations. Modules. General technical requirements. Test methods». Two more standards are under development: one of them is essentially a slightly modified version of GOST R 53291—2009 — it will be given the status of interstate; the second supplements GOST R 53286—2009 and concerns installations and modules for gas-powder fire extinguishing. Impulse fire extinguishing installations with self-foaming gas-aerosol-filled foam are not subject to the listed standards for technical requirements and test methods. This applies primarily to the requirements for the volume of vessels used to obtain foam and displace it from there, as well as for the operating time of the pulse fire extinguishing installation, measuring the rate of exit of the fire extinguishing agent, calculating this rate according to the graph of pressure change in the vessel, etc. Therefore, for these installations a separate standard is required. In this case, in general, it is required to give clear definitions of what is meant by impulse fire extinguishing and impulse fire extinguishing installations.","PeriodicalId":35650,"journal":{"name":"Bezopasnost'' Truda v Promyshlennosti","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Standardization of Impulse Extinguishing Installations for Delivery of Self Foaming Gas-aerosol Foam\",\"authors\":\"N. P. Kopylov, D. Fedotkin, E. Sushkina, V.I. Novikova\",\"doi\":\"10.24000/0409-2961-2023-7-16-20\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pulse fire extinguishing was actively developing. There is a wide range of impulse fire extinguishing devices on the market. However, existing standards do not cover the entire class of these products. Hence there are problems with their certification. To date, two standards are approved and in force: GOST R 53291—2009 «Fire-fighting equipment. Mobile and portable fire extinguishing devices with high-speed delivery of fire extinguishing agent. General technical requirements. Test methods», and GOST R 53286—2009 «Fire-fighting equipment. Automatic powder fire-extinguishing installations. Modules. General technical requirements. Test methods». Two more standards are under development: one of them is essentially a slightly modified version of GOST R 53291—2009 — it will be given the status of interstate; the second supplements GOST R 53286—2009 and concerns installations and modules for gas-powder fire extinguishing. Impulse fire extinguishing installations with self-foaming gas-aerosol-filled foam are not subject to the listed standards for technical requirements and test methods. This applies primarily to the requirements for the volume of vessels used to obtain foam and displace it from there, as well as for the operating time of the pulse fire extinguishing installation, measuring the rate of exit of the fire extinguishing agent, calculating this rate according to the graph of pressure change in the vessel, etc. Therefore, for these installations a separate standard is required. In this case, in general, it is required to give clear definitions of what is meant by impulse fire extinguishing and impulse fire extinguishing installations.\",\"PeriodicalId\":35650,\"journal\":{\"name\":\"Bezopasnost'' Truda v Promyshlennosti\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bezopasnost'' Truda v Promyshlennosti\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24000/0409-2961-2023-7-16-20\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bezopasnost'' Truda v Promyshlennosti","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24000/0409-2961-2023-7-16-20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
摘要
脉冲灭火正在积极发展。市场上有各种各样的脉冲灭火装置。然而,现有的标准并没有涵盖这些产品的全部类别。因此,他们的认证存在问题。迄今为止,有两个标准已获得批准并生效:GOST R 53291-2009《消防设备》。移动式和便携式灭火装置,可高速输送灭火剂。一般技术要求。《试验方法》和GOST R 53286-2009《消防设备》。自动粉末灭火装置。模块。一般技术要求。测试方法»。另外两个标准正在开发中:其中一个基本上是GOST R 53291-2009的略微修改版本——它将被赋予州际地位;第二个补充GOST R 53286-2009,涉及气体粉末灭火装置和模块。具有自发泡气体气溶胶填充泡沫的脉冲灭火装置不受所列技术要求和试验方法标准的约束。这主要适用于用于获得泡沫并将其从中排出的容器的体积要求,以及脉冲灭火装置的操作时间要求,测量灭火剂的排出速率,根据容器中的压力变化图计算该速率等。因此,对于这些安装,需要单独的标准。在这种情况下,通常需要对脉冲灭火和脉冲灭火装置的含义给出明确的定义。
Standardization of Impulse Extinguishing Installations for Delivery of Self Foaming Gas-aerosol Foam
Pulse fire extinguishing was actively developing. There is a wide range of impulse fire extinguishing devices on the market. However, existing standards do not cover the entire class of these products. Hence there are problems with their certification. To date, two standards are approved and in force: GOST R 53291—2009 «Fire-fighting equipment. Mobile and portable fire extinguishing devices with high-speed delivery of fire extinguishing agent. General technical requirements. Test methods», and GOST R 53286—2009 «Fire-fighting equipment. Automatic powder fire-extinguishing installations. Modules. General technical requirements. Test methods». Two more standards are under development: one of them is essentially a slightly modified version of GOST R 53291—2009 — it will be given the status of interstate; the second supplements GOST R 53286—2009 and concerns installations and modules for gas-powder fire extinguishing. Impulse fire extinguishing installations with self-foaming gas-aerosol-filled foam are not subject to the listed standards for technical requirements and test methods. This applies primarily to the requirements for the volume of vessels used to obtain foam and displace it from there, as well as for the operating time of the pulse fire extinguishing installation, measuring the rate of exit of the fire extinguishing agent, calculating this rate according to the graph of pressure change in the vessel, etc. Therefore, for these installations a separate standard is required. In this case, in general, it is required to give clear definitions of what is meant by impulse fire extinguishing and impulse fire extinguishing installations.