Yen-Chun Hsieh, Po-Hsun Lin, Pin-Hui Lee, Emily K. Kin
{"title":"膜生物反应器与反渗透一体化处理纺织废水的中试研究","authors":"Yen-Chun Hsieh, Po-Hsun Lin, Pin-Hui Lee, Emily K. Kin","doi":"10.46604/peti.2023.5273","DOIUrl":null,"url":null,"abstract":"Membrane bioreactor (MBR) technology, a combination of traditional activated sludge and membrane filtration, has been widely used for industrial wastewater treatment and reclamation. This paper highlights a pilot-scale MBR system treating textile wastewater from a textile factory in Taiwan. Over 7 months of continuous operation, the average MBR influent chemical oxygen demand (COD) is 332 mg/L, and the average effluent COD is 38 mg/L, which results in approximately 88% COD removal. A reverse osmosis (RO) module is installed after 2 months of MBR operation and uses the MBR permeate as its influent. The RO produces pure water with average COD, conductivity, and color of 7 mg/L, 16 μS/cm, and 7 Pt-Co, respectively. The RO permeate is suitable for reuse in manufacturing processes, and the RO membrane shows stable performance with TMP, which is less than or equal to 0.5 kg/cm2 during the test. The study demonstrates the great feasibility of MBR combined with RO for treating and reclaiming textile wastewater.","PeriodicalId":33402,"journal":{"name":"Proceedings of Engineering and Technology Innovation","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Integration of Membrane Bioreactor and Reverse Osmosis for Textile Wastewater Treatment and Reclamation: A Pilot-Scale Study\",\"authors\":\"Yen-Chun Hsieh, Po-Hsun Lin, Pin-Hui Lee, Emily K. Kin\",\"doi\":\"10.46604/peti.2023.5273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Membrane bioreactor (MBR) technology, a combination of traditional activated sludge and membrane filtration, has been widely used for industrial wastewater treatment and reclamation. This paper highlights a pilot-scale MBR system treating textile wastewater from a textile factory in Taiwan. Over 7 months of continuous operation, the average MBR influent chemical oxygen demand (COD) is 332 mg/L, and the average effluent COD is 38 mg/L, which results in approximately 88% COD removal. A reverse osmosis (RO) module is installed after 2 months of MBR operation and uses the MBR permeate as its influent. The RO produces pure water with average COD, conductivity, and color of 7 mg/L, 16 μS/cm, and 7 Pt-Co, respectively. The RO permeate is suitable for reuse in manufacturing processes, and the RO membrane shows stable performance with TMP, which is less than or equal to 0.5 kg/cm2 during the test. The study demonstrates the great feasibility of MBR combined with RO for treating and reclaiming textile wastewater.\",\"PeriodicalId\":33402,\"journal\":{\"name\":\"Proceedings of Engineering and Technology Innovation\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Engineering and Technology Innovation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46604/peti.2023.5273\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Engineering and Technology Innovation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46604/peti.2023.5273","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Integration of Membrane Bioreactor and Reverse Osmosis for Textile Wastewater Treatment and Reclamation: A Pilot-Scale Study
Membrane bioreactor (MBR) technology, a combination of traditional activated sludge and membrane filtration, has been widely used for industrial wastewater treatment and reclamation. This paper highlights a pilot-scale MBR system treating textile wastewater from a textile factory in Taiwan. Over 7 months of continuous operation, the average MBR influent chemical oxygen demand (COD) is 332 mg/L, and the average effluent COD is 38 mg/L, which results in approximately 88% COD removal. A reverse osmosis (RO) module is installed after 2 months of MBR operation and uses the MBR permeate as its influent. The RO produces pure water with average COD, conductivity, and color of 7 mg/L, 16 μS/cm, and 7 Pt-Co, respectively. The RO permeate is suitable for reuse in manufacturing processes, and the RO membrane shows stable performance with TMP, which is less than or equal to 0.5 kg/cm2 during the test. The study demonstrates the great feasibility of MBR combined with RO for treating and reclaiming textile wastewater.