胆道支架偏离引起的并发症

K. Kumar, S. Fukuchi, K. Murakami
{"title":"胆道支架偏离引起的并发症","authors":"K. Kumar, S. Fukuchi, K. Murakami","doi":"10.26420/austinjgastroenterol.2021.1112","DOIUrl":null,"url":null,"abstract":"We often encounter complications from biliary stents used as a treatment for obstructive jaundice and acute cholangitis. Early complications after stent placement include pancreatitis, bleeding, and duodenal perforation [1]. Stent deviation is also a complication. This is particularly prominent for plastic stents, where stent deviation is observed in 6-18.7 % of cases [2]. Stent deviation is more common among patients who have undergone endoscopic sphincterotomy (Figure 1). Most deviated biliary plastic stents are excreted in stool or collected endoscopically, but, very rarely, complications causing gastrointestinal perforation have been reported. We have described deviated biliary plastic stents causing sigmoid colon diverticulum perforation and even uterine appendage penetration (Figure 2). Diagnosis can be made from clinical symptoms and abdominal computed tomography. Treatment is basically surgery. Biliary stent-related complications are inevitable, and sometimes become serious. On suspicion of such complications, the most important issue is to accurately and rapidly diagnose complications and conduct appropriate management.","PeriodicalId":93268,"journal":{"name":"Austin journal of gastroenterology","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Complications due to Biliary Stent Deviation\",\"authors\":\"K. Kumar, S. Fukuchi, K. Murakami\",\"doi\":\"10.26420/austinjgastroenterol.2021.1112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We often encounter complications from biliary stents used as a treatment for obstructive jaundice and acute cholangitis. Early complications after stent placement include pancreatitis, bleeding, and duodenal perforation [1]. Stent deviation is also a complication. This is particularly prominent for plastic stents, where stent deviation is observed in 6-18.7 % of cases [2]. Stent deviation is more common among patients who have undergone endoscopic sphincterotomy (Figure 1). Most deviated biliary plastic stents are excreted in stool or collected endoscopically, but, very rarely, complications causing gastrointestinal perforation have been reported. We have described deviated biliary plastic stents causing sigmoid colon diverticulum perforation and even uterine appendage penetration (Figure 2). Diagnosis can be made from clinical symptoms and abdominal computed tomography. Treatment is basically surgery. Biliary stent-related complications are inevitable, and sometimes become serious. On suspicion of such complications, the most important issue is to accurately and rapidly diagnose complications and conduct appropriate management.\",\"PeriodicalId\":93268,\"journal\":{\"name\":\"Austin journal of gastroenterology\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Austin journal of gastroenterology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26420/austinjgastroenterol.2021.1112\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Austin journal of gastroenterology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/austinjgastroenterol.2021.1112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们经常会遇到胆道支架治疗梗阻性黄疸和急性胆管炎的并发症。支架置入术后的早期并发症包括胰腺炎、出血和十二指肠穿孔。支架偏差也是一个并发症。这在塑料支架中尤为突出,在6- 18.7%的病例中观察到支架偏差。支架偏曲在内镜下行括约肌切开术的患者中更为常见(图1)。大多数偏曲的胆道塑料支架随粪便排出或在内镜下收集,但很少有引起胃肠道穿孔的并发症报道。我们描述了胆道塑料支架偏离导致乙状结肠憩室穿孔甚至子宫附件穿透(图2)。诊断可通过临床症状和腹部计算机断层扫描。治疗基本上是手术。胆道支架相关的并发症是不可避免的,有时会变得严重。在怀疑出现此类并发症时,最重要的问题是准确、快速地诊断并发症并进行适当的处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Complications due to Biliary Stent Deviation
We often encounter complications from biliary stents used as a treatment for obstructive jaundice and acute cholangitis. Early complications after stent placement include pancreatitis, bleeding, and duodenal perforation [1]. Stent deviation is also a complication. This is particularly prominent for plastic stents, where stent deviation is observed in 6-18.7 % of cases [2]. Stent deviation is more common among patients who have undergone endoscopic sphincterotomy (Figure 1). Most deviated biliary plastic stents are excreted in stool or collected endoscopically, but, very rarely, complications causing gastrointestinal perforation have been reported. We have described deviated biliary plastic stents causing sigmoid colon diverticulum perforation and even uterine appendage penetration (Figure 2). Diagnosis can be made from clinical symptoms and abdominal computed tomography. Treatment is basically surgery. Biliary stent-related complications are inevitable, and sometimes become serious. On suspicion of such complications, the most important issue is to accurately and rapidly diagnose complications and conduct appropriate management.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信