小型水培系统的电池管理及栽培试验

IF 0.5 Q4 ENGINEERING, MANUFACTURING
S. Yamaguchi, Takuya Motosugi, Yoshihiko Takahashi
{"title":"小型水培系统的电池管理及栽培试验","authors":"S. Yamaguchi, Takuya Motosugi, Yoshihiko Takahashi","doi":"10.4018/IJMMME.2021070102","DOIUrl":null,"url":null,"abstract":"A small hydroponic system that can use sustainable energy such as solar power has been developed. However, the amount of power generated is not constant, and in the case of unstable weather, enough power cannot be obtained. Therefore, it is necessary to store the generated energy in a battery. In order to design low-cost charging equipment, it is necessary to use a smaller battery and to estimate the remaining charge capacity (state of charge: SOC) accurately. To provide an accurate SOC estimation for such systems, a fusion of CI (current integral) and OCV (open circuit voltage) methods is proposed. When using this method, it is necessary to frequently disconnect the electronic load. In these experiments, the optimum disconnection duration, the effects on plants of frequent battery disconnection, and cutting off of the lighting were investigated.","PeriodicalId":43174,"journal":{"name":"International Journal of Manufacturing Materials and Mechanical Engineering","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Battery Management for Small Hydroponic Systems and Cultivation Experiments\",\"authors\":\"S. Yamaguchi, Takuya Motosugi, Yoshihiko Takahashi\",\"doi\":\"10.4018/IJMMME.2021070102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A small hydroponic system that can use sustainable energy such as solar power has been developed. However, the amount of power generated is not constant, and in the case of unstable weather, enough power cannot be obtained. Therefore, it is necessary to store the generated energy in a battery. In order to design low-cost charging equipment, it is necessary to use a smaller battery and to estimate the remaining charge capacity (state of charge: SOC) accurately. To provide an accurate SOC estimation for such systems, a fusion of CI (current integral) and OCV (open circuit voltage) methods is proposed. When using this method, it is necessary to frequently disconnect the electronic load. In these experiments, the optimum disconnection duration, the effects on plants of frequent battery disconnection, and cutting off of the lighting were investigated.\",\"PeriodicalId\":43174,\"journal\":{\"name\":\"International Journal of Manufacturing Materials and Mechanical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2021-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Manufacturing Materials and Mechanical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4018/IJMMME.2021070102\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MANUFACTURING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Manufacturing Materials and Mechanical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4018/IJMMME.2021070102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 1

摘要

一种可以使用太阳能等可持续能源的小型水培系统已经开发出来。然而,发电量不是恒定的,在天气不稳定的情况下,无法获得足够的电力。因此,有必要将产生的能量储存在电池中。为了设计低成本的充电设备,必须使用更小的电池,并准确地估计剩余充电容量(充电状态:SOC)。为了对此类系统提供准确的SOC估计,提出了一种融合CI(电流积分)和OCV(开路电压)的方法。使用这种方法时,需要经常断开电子负载。在这些实验中,研究了最佳断电时间、频繁断电和切断照明对植物的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Battery Management for Small Hydroponic Systems and Cultivation Experiments
A small hydroponic system that can use sustainable energy such as solar power has been developed. However, the amount of power generated is not constant, and in the case of unstable weather, enough power cannot be obtained. Therefore, it is necessary to store the generated energy in a battery. In order to design low-cost charging equipment, it is necessary to use a smaller battery and to estimate the remaining charge capacity (state of charge: SOC) accurately. To provide an accurate SOC estimation for such systems, a fusion of CI (current integral) and OCV (open circuit voltage) methods is proposed. When using this method, it is necessary to frequently disconnect the electronic load. In these experiments, the optimum disconnection duration, the effects on plants of frequent battery disconnection, and cutting off of the lighting were investigated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
21
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信