{"title":"三种用于乳牙的根管材料的推出结合强度的体外研究","authors":"Hazal Özer, Merve Abaklı İnci, Sevcihan Acar Tuzluca","doi":"10.3389/fdmed.2023.1140794","DOIUrl":null,"url":null,"abstract":"The study aims to compare the bond strength of three primary tooth root canal filling materials to the root canal wall with a push-out test (Calplus, Diapaste, BIOfactor MTA). First, 30 primary central teeth were cut transversely using a water-cooled low-speed diamond saw vertical to the long axis to obtain 2 mm thick discs from the middle third of the roots. Next the materials used were placed on dentin discs and kept in an incubator for 1 week at 37°C and 100% humidity until the hardening mechanism of the root-canal sealer was completed. Finally, a vertical force was placed on each material from apical to coronal with a 0.75 mm diameter stainless steel cylindrical piston without contacting the root canal dentin. The data were analyzed using the SPSS 22.0 program and Mann-Whitney U test was used as a post hoc test. There was a statistically significant difference between the bonding values of different primary tooth root canal sealers to root canal dentin (p < 0.05). Among the maximum binding values, the lowest measurement was in Calplus (0.43 ± 0.28 MPa), and the highest measurement was in BIOfactor MTA (24.24 ± 17.78 MPa) (p < 0.05). BIOfactor MTA has a higher bonding value to root canal dentin than calcium hydroxide-based primary tooth canal sealers.","PeriodicalId":73077,"journal":{"name":"Frontiers in dental medicine","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The push-out bond strength of three root canal materials used in primary teeth: In vitro study\",\"authors\":\"Hazal Özer, Merve Abaklı İnci, Sevcihan Acar Tuzluca\",\"doi\":\"10.3389/fdmed.2023.1140794\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study aims to compare the bond strength of three primary tooth root canal filling materials to the root canal wall with a push-out test (Calplus, Diapaste, BIOfactor MTA). First, 30 primary central teeth were cut transversely using a water-cooled low-speed diamond saw vertical to the long axis to obtain 2 mm thick discs from the middle third of the roots. Next the materials used were placed on dentin discs and kept in an incubator for 1 week at 37°C and 100% humidity until the hardening mechanism of the root-canal sealer was completed. Finally, a vertical force was placed on each material from apical to coronal with a 0.75 mm diameter stainless steel cylindrical piston without contacting the root canal dentin. The data were analyzed using the SPSS 22.0 program and Mann-Whitney U test was used as a post hoc test. There was a statistically significant difference between the bonding values of different primary tooth root canal sealers to root canal dentin (p < 0.05). Among the maximum binding values, the lowest measurement was in Calplus (0.43 ± 0.28 MPa), and the highest measurement was in BIOfactor MTA (24.24 ± 17.78 MPa) (p < 0.05). BIOfactor MTA has a higher bonding value to root canal dentin than calcium hydroxide-based primary tooth canal sealers.\",\"PeriodicalId\":73077,\"journal\":{\"name\":\"Frontiers in dental medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in dental medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3389/fdmed.2023.1140794\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in dental medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fdmed.2023.1140794","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
The push-out bond strength of three root canal materials used in primary teeth: In vitro study
The study aims to compare the bond strength of three primary tooth root canal filling materials to the root canal wall with a push-out test (Calplus, Diapaste, BIOfactor MTA). First, 30 primary central teeth were cut transversely using a water-cooled low-speed diamond saw vertical to the long axis to obtain 2 mm thick discs from the middle third of the roots. Next the materials used were placed on dentin discs and kept in an incubator for 1 week at 37°C and 100% humidity until the hardening mechanism of the root-canal sealer was completed. Finally, a vertical force was placed on each material from apical to coronal with a 0.75 mm diameter stainless steel cylindrical piston without contacting the root canal dentin. The data were analyzed using the SPSS 22.0 program and Mann-Whitney U test was used as a post hoc test. There was a statistically significant difference between the bonding values of different primary tooth root canal sealers to root canal dentin (p < 0.05). Among the maximum binding values, the lowest measurement was in Calplus (0.43 ± 0.28 MPa), and the highest measurement was in BIOfactor MTA (24.24 ± 17.78 MPa) (p < 0.05). BIOfactor MTA has a higher bonding value to root canal dentin than calcium hydroxide-based primary tooth canal sealers.