{"title":"电渗透中界面阻力的测量方法及特性","authors":"Kang-shi Guo, Y. Zhuang","doi":"10.1680/jgein.22.00156","DOIUrl":null,"url":null,"abstract":"The electro-osmosis technique can be used for rapid dewatering and consolidation of deep soft foundations. Considering the abnormal volt-ampere characteristics of soil at the initial stage of electro-osmosis using electrokinetic geosynthetics (EKG) electrodes, the hypothesis that the interfacial resistance between electrode and soil is related to current was formulated. A new method was used to distinguish the soil resistance and interfacial resistance, and an experiment was designed to verify them. The results show that the soil resistance does not change with the changing current in the circuit, but the interfacial resistance is closely related to the current. The interfacial resistance decreases as the current increases and is approximately a power function of the current. This relationship applies to aluminium, copper, iron and EKG electrodes. In addition, a design for the field application of electro-osmosis was developed focusing on power supply and efficiency. The calculation results show that the proportion of soil effective potential is closely related to the potential gradient imposed by the power supply. The experimental results reveal the relationship between the potential gradient and the efficiency of electro-osmosis, which provides a theoretical basis for the determination and optimisation of electric power in electro-osmosis system design.","PeriodicalId":12616,"journal":{"name":"Geosynthetics International","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2022-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement methodology and characteristics of interfacial resistance in electro-osmosis\",\"authors\":\"Kang-shi Guo, Y. Zhuang\",\"doi\":\"10.1680/jgein.22.00156\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The electro-osmosis technique can be used for rapid dewatering and consolidation of deep soft foundations. Considering the abnormal volt-ampere characteristics of soil at the initial stage of electro-osmosis using electrokinetic geosynthetics (EKG) electrodes, the hypothesis that the interfacial resistance between electrode and soil is related to current was formulated. A new method was used to distinguish the soil resistance and interfacial resistance, and an experiment was designed to verify them. The results show that the soil resistance does not change with the changing current in the circuit, but the interfacial resistance is closely related to the current. The interfacial resistance decreases as the current increases and is approximately a power function of the current. This relationship applies to aluminium, copper, iron and EKG electrodes. In addition, a design for the field application of electro-osmosis was developed focusing on power supply and efficiency. The calculation results show that the proportion of soil effective potential is closely related to the potential gradient imposed by the power supply. The experimental results reveal the relationship between the potential gradient and the efficiency of electro-osmosis, which provides a theoretical basis for the determination and optimisation of electric power in electro-osmosis system design.\",\"PeriodicalId\":12616,\"journal\":{\"name\":\"Geosynthetics International\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2022-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Geosynthetics International\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1680/jgein.22.00156\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, GEOLOGICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geosynthetics International","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1680/jgein.22.00156","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 0

摘要

电渗透技术可用于深层软基的快速脱水和固结。考虑到电动土工合成材料电极电渗初期土壤的异常伏安特性,提出了电极与土壤界面电阻与电流有关的假设。采用一种新的方法来区分土壤阻力和界面阻力,并设计了一个实验来验证它们。结果表明,土壤电阻不随电路中电流的变化而变化,但界面电阻与电流密切相关。界面电阻随着电流的增加而减小,并且近似为电流的幂函数。这种关系适用于铝、铜、铁和心电图电极。此外,还开发了一个针对电渗现场应用的设计,重点关注电源和效率。计算结果表明,土壤有效电位的比例与电源施加的电位梯度密切相关。实验结果揭示了电位梯度与电渗效率之间的关系,为电渗系统设计中电功率的确定和优化提供了理论依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement methodology and characteristics of interfacial resistance in electro-osmosis
The electro-osmosis technique can be used for rapid dewatering and consolidation of deep soft foundations. Considering the abnormal volt-ampere characteristics of soil at the initial stage of electro-osmosis using electrokinetic geosynthetics (EKG) electrodes, the hypothesis that the interfacial resistance between electrode and soil is related to current was formulated. A new method was used to distinguish the soil resistance and interfacial resistance, and an experiment was designed to verify them. The results show that the soil resistance does not change with the changing current in the circuit, but the interfacial resistance is closely related to the current. The interfacial resistance decreases as the current increases and is approximately a power function of the current. This relationship applies to aluminium, copper, iron and EKG electrodes. In addition, a design for the field application of electro-osmosis was developed focusing on power supply and efficiency. The calculation results show that the proportion of soil effective potential is closely related to the potential gradient imposed by the power supply. The experimental results reveal the relationship between the potential gradient and the efficiency of electro-osmosis, which provides a theoretical basis for the determination and optimisation of electric power in electro-osmosis system design.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Geosynthetics International
Geosynthetics International ENGINEERING, GEOLOGICAL-GEOSCIENCES, MULTIDISCIPLINARY
CiteScore
6.90
自引率
20.00%
发文量
91
审稿时长
>12 weeks
期刊介绍: An online only, rapid publication journal, Geosynthetics International – an official journal of the International Geosynthetics Society (IGS) – publishes the best information on current geosynthetics technology in research, design innovation, new materials and construction practice. Topics covered The whole of geosynthetic materials (including natural fibre products) such as research, behaviour, performance analysis, testing, design, construction methods, case histories and field experience. Geosynthetics International is received by all members of the IGS as part of their membership, and is published in e-only format six times a year.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信