{"title":"考虑几何参数的螺栓连接超高性能混凝土板节点强度与性能","authors":"Yang-Hee Kwon, S. Chung, Sung-Gul Hong","doi":"10.4172/2168-9873.1000261","DOIUrl":null,"url":null,"abstract":"One of the most reasonable ways to connect thin ultra-high performance concrete (UHPC) facades to building structures is bolted joints. To design the joints for the facades economically and safely, a clear investigation of the structural behavior is needed. In this study, the joint strength, failure modes and strain concentration phenomena of the bolted UHPC panels are investigated by direct tensile test. The main experimental variables are the geometric parameters, which are the width of the specimen, its thickness, and the distance from the center of the hole to the edge. Experimental results show that ductility of the joint depends on the failure mode. In addition, it is shown that the increase in the material cost of the panel, such as size and thickness, does not necessarily lead to an increase in the joint strength.","PeriodicalId":90573,"journal":{"name":"Journal of applied mechanical engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4172/2168-9873.1000261","citationCount":"3","resultStr":"{\"title\":\"Strength and Behavior of Bolted Ultra-High Performance Concrete PanelJoint with Geometric Parameter\",\"authors\":\"Yang-Hee Kwon, S. Chung, Sung-Gul Hong\",\"doi\":\"10.4172/2168-9873.1000261\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the most reasonable ways to connect thin ultra-high performance concrete (UHPC) facades to building structures is bolted joints. To design the joints for the facades economically and safely, a clear investigation of the structural behavior is needed. In this study, the joint strength, failure modes and strain concentration phenomena of the bolted UHPC panels are investigated by direct tensile test. The main experimental variables are the geometric parameters, which are the width of the specimen, its thickness, and the distance from the center of the hole to the edge. Experimental results show that ductility of the joint depends on the failure mode. In addition, it is shown that the increase in the material cost of the panel, such as size and thickness, does not necessarily lead to an increase in the joint strength.\",\"PeriodicalId\":90573,\"journal\":{\"name\":\"Journal of applied mechanical engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4172/2168-9873.1000261\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of applied mechanical engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2168-9873.1000261\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied mechanical engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2168-9873.1000261","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

连接超薄高性能混凝土(UHPC)外墙与建筑结构的最合理方法之一是螺栓连接。为了经济、安全地设计立面接缝,需要对结构性能进行明确的研究。通过直接拉伸试验,研究了螺栓连接的UHPC板的连接强度、破坏模式和应变集中现象。主要的实验变量是几何参数,即试样的宽度、厚度和孔中心到边缘的距离。试验结果表明,节点的延性与破坏模式有关。此外,表明面板的材料成本的增加,如尺寸和厚度,并不一定导致接头强度的增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Strength and Behavior of Bolted Ultra-High Performance Concrete PanelJoint with Geometric Parameter
One of the most reasonable ways to connect thin ultra-high performance concrete (UHPC) facades to building structures is bolted joints. To design the joints for the facades economically and safely, a clear investigation of the structural behavior is needed. In this study, the joint strength, failure modes and strain concentration phenomena of the bolted UHPC panels are investigated by direct tensile test. The main experimental variables are the geometric parameters, which are the width of the specimen, its thickness, and the distance from the center of the hole to the edge. Experimental results show that ductility of the joint depends on the failure mode. In addition, it is shown that the increase in the material cost of the panel, such as size and thickness, does not necessarily lead to an increase in the joint strength.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信