变异型血红蛋白E表型上检测不到的高效液相色谱法血红蛋白A1c:一例报告。

Nadia Sadriani, Ferdy Royland Marpaung
{"title":"变异型血红蛋白E表型上检测不到的高效液相色谱法血红蛋白A1c:一例报告。","authors":"Nadia Sadriani,&nbsp;Ferdy Royland Marpaung","doi":"10.11613/BM.2023.030801","DOIUrl":null,"url":null,"abstract":"<p><p>The gold standard for long-term monitoring of diabetic patients is glycated haemoglobin (HbA1c), which is routinely tested for glycaemic control. Furthermore, the National glycohemoglobin standardization program (NGSP) has designated high-performance liquid chromatography (HPLC) as the reference method for HbA1c measurement. A woman from the Sumba tribe, Indonesia, aged 52, visited the Internal Medicine Clinic for a routine check-up. She had been taking diabetic and hypertension medicines on a regular basis for over 10 years. The HPLC procedure yielded \"no result\" for the patient's HbA1c assessment and there was no peak on the HPLC graphic. However, there was a discrepancy between the data history of HbA1c measured by turbidimetric method (average of 51 mmol/mol, reference range < 48 mmol/mol), fasting blood glucose (average of 7.7 mmol/L, reference range < 7.0 mmol/L) and 2-hour plasma glucose (average of 13 mmol/L, reference range < 11.1 mmol/L). Glycated albumin was 3.1 mmol/L (reference range 1.8-2.4 mmol/L). Haemoglobin electrophoresis identified homozygote haemoglobinopathy E (HbE). Patients with haemoglobin variants are proposed to utilize glycated albumin.</p>","PeriodicalId":94370,"journal":{"name":"Biochemia medica","volume":"33 3","pages":"030801"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10564149/pdf/","citationCount":"0","resultStr":"{\"title\":\"Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.\",\"authors\":\"Nadia Sadriani,&nbsp;Ferdy Royland Marpaung\",\"doi\":\"10.11613/BM.2023.030801\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The gold standard for long-term monitoring of diabetic patients is glycated haemoglobin (HbA1c), which is routinely tested for glycaemic control. Furthermore, the National glycohemoglobin standardization program (NGSP) has designated high-performance liquid chromatography (HPLC) as the reference method for HbA1c measurement. A woman from the Sumba tribe, Indonesia, aged 52, visited the Internal Medicine Clinic for a routine check-up. She had been taking diabetic and hypertension medicines on a regular basis for over 10 years. The HPLC procedure yielded \\\"no result\\\" for the patient's HbA1c assessment and there was no peak on the HPLC graphic. However, there was a discrepancy between the data history of HbA1c measured by turbidimetric method (average of 51 mmol/mol, reference range < 48 mmol/mol), fasting blood glucose (average of 7.7 mmol/L, reference range < 7.0 mmol/L) and 2-hour plasma glucose (average of 13 mmol/L, reference range < 11.1 mmol/L). Glycated albumin was 3.1 mmol/L (reference range 1.8-2.4 mmol/L). Haemoglobin electrophoresis identified homozygote haemoglobinopathy E (HbE). Patients with haemoglobin variants are proposed to utilize glycated albumin.</p>\",\"PeriodicalId\":94370,\"journal\":{\"name\":\"Biochemia medica\",\"volume\":\"33 3\",\"pages\":\"030801\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10564149/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biochemia medica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11613/BM.2023.030801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemia medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11613/BM.2023.030801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

糖尿病患者长期监测的金标准是糖化血红蛋白(HbA1c),它是血糖控制的常规测试。此外,国家糖化血红蛋白标准化计划(NGSP)已指定高效液相色谱法(HPLC)作为HbA1c测量的参考方法。一名来自印度尼西亚Sumba部落的52岁妇女前往内科诊所进行常规检查。10多年来,她一直定期服用糖尿病和高血压药物。HPLC程序对患者的HbA1c评估“没有结果”,HPLC图上也没有峰值。然而,浊度法测得的HbA1c数据史(平均值51 mmol/mol,参考范围<48 mmol/mol)、空腹血糖(平均值7.7 mmol/L,参考范围<7.0 mmol/L)和2小时血糖(平均13 mmol/L,参照范围<11.1 mmol/L)之间存在差异。糖化白蛋白为3.1 mmol/L(参考范围1.8-2.4 mmol/L)。血红蛋白电泳鉴定纯合血红蛋白病E(HbE)。有血红蛋白变体的患者被建议使用糖化白蛋白。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.

Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.

Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.

Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report.

The gold standard for long-term monitoring of diabetic patients is glycated haemoglobin (HbA1c), which is routinely tested for glycaemic control. Furthermore, the National glycohemoglobin standardization program (NGSP) has designated high-performance liquid chromatography (HPLC) as the reference method for HbA1c measurement. A woman from the Sumba tribe, Indonesia, aged 52, visited the Internal Medicine Clinic for a routine check-up. She had been taking diabetic and hypertension medicines on a regular basis for over 10 years. The HPLC procedure yielded "no result" for the patient's HbA1c assessment and there was no peak on the HPLC graphic. However, there was a discrepancy between the data history of HbA1c measured by turbidimetric method (average of 51 mmol/mol, reference range < 48 mmol/mol), fasting blood glucose (average of 7.7 mmol/L, reference range < 7.0 mmol/L) and 2-hour plasma glucose (average of 13 mmol/L, reference range < 11.1 mmol/L). Glycated albumin was 3.1 mmol/L (reference range 1.8-2.4 mmol/L). Haemoglobin electrophoresis identified homozygote haemoglobinopathy E (HbE). Patients with haemoglobin variants are proposed to utilize glycated albumin.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信