弯曲渠道中渠道运输和中心率的比较评估:锥形束计算机断层扫描和微型计算机断层扫描的研究。

Q3 Dentistry
Yazdan Shantiaee, Babak Zandi, Ali Rahbar Taramsari, Alireza Akbarzadeh Baghban, Nazanin Zargar, Shiva Shojaeian, Niloofar Mortezapour, Kourosh Shantiaee, Fatemeh Soltaninejad
{"title":"弯曲渠道中渠道运输和中心率的比较评估:锥形束计算机断层扫描和微型计算机断层扫描的研究。","authors":"Yazdan Shantiaee,&nbsp;Babak Zandi,&nbsp;Ali Rahbar Taramsari,&nbsp;Alireza Akbarzadeh Baghban,&nbsp;Nazanin Zargar,&nbsp;Shiva Shojaeian,&nbsp;Niloofar Mortezapour,&nbsp;Kourosh Shantiaee,&nbsp;Fatemeh Soltaninejad","doi":"10.22037/iej.v18i4.41541","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files.</p><p><strong>Material and methods: </strong>Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA.</p><p><strong>Results: </strong>Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods.</p><p><strong>Conclusions: </strong>CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings.</p>","PeriodicalId":14534,"journal":{"name":"Iranian Endodontic Journal","volume":"18 4","pages":"241-247"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/32/78/IEJ-18-241.PMC10566004.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography.\",\"authors\":\"Yazdan Shantiaee,&nbsp;Babak Zandi,&nbsp;Ali Rahbar Taramsari,&nbsp;Alireza Akbarzadeh Baghban,&nbsp;Nazanin Zargar,&nbsp;Shiva Shojaeian,&nbsp;Niloofar Mortezapour,&nbsp;Kourosh Shantiaee,&nbsp;Fatemeh Soltaninejad\",\"doi\":\"10.22037/iej.v18i4.41541\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files.</p><p><strong>Material and methods: </strong>Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA.</p><p><strong>Results: </strong>Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods.</p><p><strong>Conclusions: </strong>CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings.</p>\",\"PeriodicalId\":14534,\"journal\":{\"name\":\"Iranian Endodontic Journal\",\"volume\":\"18 4\",\"pages\":\"241-247\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/32/78/IEJ-18-241.PMC10566004.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Endodontic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22037/iej.v18i4.41541\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22037/iej.v18i4.41541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

引言:本研究旨在比较锥形束计算机断层扫描(CBCT)和微型计算机断层扫描在使用旋转锉进行根管器械后评估根管运输和定心率方面的准确性和一致性。材料与方法:采用2Shape序列旋转系统制备20根下颌磨牙近中颊根管。在仪器前后进行CBCT和显微CT扫描,并测量运输量和定心率。可接受的传输设置为≤0.15mm。计算CBCT和micro-CT之间的准确性和一致性,并确定类内相关系数(ICC)和kappa系数,以评估两种模式之间的一致性。使用重复测量ANOVA进行统计分析。结果:两种模式在器械植入后距离顶点的所有距离都能检测到运输。在距离根尖1、3、5和7 mm处,分别有80%、85%、75%和75%的标本观察到CBCT和micro-CT在评估椎管运输方面的一致性。运输和居中比率的ICC远低于0.75,表明两种模式之间的一致性较差。kappa系数未显示出两种方法之间可接受的一致性。结论:CBCT和micro-CT在评估椎管运输和定心率方面的一致性较差。显微CT仍然是体外研究的首选方式,而CBCT应仅限于临床环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography.

Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography.

Introduction: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files.

Material and methods: Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA.

Results: Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods.

Conclusions: CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iranian Endodontic Journal
Iranian Endodontic Journal Dentistry-Dentistry (all)
CiteScore
1.30
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊介绍: The Iranian Endodontic Journal (IEJ) is an international peer-reviewed biomedical publication, the aim of which is to provide a scientific medium of communication for researchers throughout the globe. IEJ aims to publish the highest quality articles, both clinical and scientific, on all aspects of Endodontics. The journal is an official Journal of the Iranian Center for Endodontic Research (ICER) and the Iranian Association of Endodontists (IAE). The Journal welcomes articles related to the scientific or applied aspects of endodontics e.g. original researches, systematic reviews, meta-analyses, review articles, clinical trials, case series/reports, hypotheses, letters to the editor, etc. From the beginning (i.e. since 2006), the IEJ was the first open access endodontic journal in the world, which gave readers free and instant access to published articles and enabling them faster discovery of the latest endodontic research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信