一种用于开放性胸腹主动脉瘤修复的新型混合移植物。

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
ACS Applied Electronic Materials Pub Date : 2023-09-28 Epub Date: 2023-09-04 DOI:10.21037/acs-2023-scp-12
Sabine Helena Wipper, Tilo Kölbel, Julia Dumfarth, Hubert Schelzig, Anthony L Estrera, Harleen K Sandhu, Florian Enzmann, E Sebastian Debus
{"title":"一种用于开放性胸腹主动脉瘤修复的新型混合移植物。","authors":"Sabine Helena Wipper, Tilo Kölbel, Julia Dumfarth, Hubert Schelzig, Anthony L Estrera, Harleen K Sandhu, Florian Enzmann, E Sebastian Debus","doi":"10.21037/acs-2023-scp-12","DOIUrl":null,"url":null,"abstract":"The Thoracoflo graft was developed as a new hybrid device for thoracoabdominal aortic aneurysm (TAAA) repair. The aim was to offer strategies to mitigate perioperative mortality/morbidity through a combined endovascular thoracic and open abdominal aortic singlestage operation. The SPIDER technique for graft implantation allows temporary, pulsatile distal perfusion of visceral, renal, and iliac arteries via a side-branch attached to the common iliac artery following the deployment of the stent-supported part of the device. Thoracotomy, radiation, and extracorporeal circulation (ECC) can be avoided, while enabling reimplantation of visceral, renal, and lumbar arteries (1-5).","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2023-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a6/ea/acs-12-05-503.PMC10561343.pdf","citationCount":"0","resultStr":"{\"title\":\"A new hybrid graft for open thoracoabdominal aortic aneurysm repair.\",\"authors\":\"Sabine Helena Wipper, Tilo Kölbel, Julia Dumfarth, Hubert Schelzig, Anthony L Estrera, Harleen K Sandhu, Florian Enzmann, E Sebastian Debus\",\"doi\":\"10.21037/acs-2023-scp-12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Thoracoflo graft was developed as a new hybrid device for thoracoabdominal aortic aneurysm (TAAA) repair. The aim was to offer strategies to mitigate perioperative mortality/morbidity through a combined endovascular thoracic and open abdominal aortic singlestage operation. The SPIDER technique for graft implantation allows temporary, pulsatile distal perfusion of visceral, renal, and iliac arteries via a side-branch attached to the common iliac artery following the deployment of the stent-supported part of the device. Thoracotomy, radiation, and extracorporeal circulation (ECC) can be avoided, while enabling reimplantation of visceral, renal, and lumbar arteries (1-5).\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2023-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a6/ea/acs-12-05-503.PMC10561343.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.21037/acs-2023-scp-12\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/acs-2023-scp-12","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new hybrid graft for open thoracoabdominal aortic aneurysm repair.
The Thoracoflo graft was developed as a new hybrid device for thoracoabdominal aortic aneurysm (TAAA) repair. The aim was to offer strategies to mitigate perioperative mortality/morbidity through a combined endovascular thoracic and open abdominal aortic singlestage operation. The SPIDER technique for graft implantation allows temporary, pulsatile distal perfusion of visceral, renal, and iliac arteries via a side-branch attached to the common iliac artery following the deployment of the stent-supported part of the device. Thoracotomy, radiation, and extracorporeal circulation (ECC) can be avoided, while enabling reimplantation of visceral, renal, and lumbar arteries (1-5).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信