{"title":"个人听力设备使用者颈前庭诱发肌源性电位的探索性研究。","authors":"Teja Deepak Dessai, Rashmi J Bhat, Kaushlendra Kumar","doi":"10.4103/nah.nah_13_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Context: </strong>The use of personal listening devices (PLDs) is becoming increasingly popular, particularly among young people. Numerous studies have demonstrated that being exposed to PLDs can have adverse effects on the auditory system. Owing to the similarities between the auditory and vestibular systems, it is possible that the negative effects of PLD use may extend to the vestibular system, an area that has not been extensively studied.</p><p><strong>Aim: </strong>The study aimed to investigate the impact of exposure to PLDs on the vestibular system, specifically the sacculo-collic reflex assessed by the cervical vestibular-evoked myogenic potential.</p><p><strong>Settings and design: </strong>The current study used a cross-sectional study design.</p><p><strong>Materials and methods: </strong>A total of 80 participants were divided into four groups based on the history of PLD exposure. Each group consisted of 20 participants who underwent cervical vestibular-evoked myogenic potential (cVEMP) testing using alternating polarity 500 Hz tone bursts.</p><p><strong>Statistical analysis used: </strong>Analysis of variance (ANOVA) and Bonferroni post hoc test were used to obtain the statistically significant difference among the group.</p><p><strong>Results: </strong>The results showed that the amplitude of p1-n1 of cVEMP was significantly reduced in individuals with longer PLD exposure duration.</p><p><strong>Conclusion: </strong>The study suggests that listening to music through a PLD at high levels of volume controls could be deleterious to the vestibular well-being of an individual. The study highlights the importance of being aware of the adverse effects of using PLDs to prevent potential damage to the vestibular systems.</p>","PeriodicalId":19195,"journal":{"name":"Noise & Health","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10747808/pdf/","citationCount":"0","resultStr":"{\"title\":\"An Exploratory Study of Cervical Vestibular-Evoked Myogenic Potential in Users of Personal Listening Devices.\",\"authors\":\"Teja Deepak Dessai, Rashmi J Bhat, Kaushlendra Kumar\",\"doi\":\"10.4103/nah.nah_13_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Context: </strong>The use of personal listening devices (PLDs) is becoming increasingly popular, particularly among young people. Numerous studies have demonstrated that being exposed to PLDs can have adverse effects on the auditory system. Owing to the similarities between the auditory and vestibular systems, it is possible that the negative effects of PLD use may extend to the vestibular system, an area that has not been extensively studied.</p><p><strong>Aim: </strong>The study aimed to investigate the impact of exposure to PLDs on the vestibular system, specifically the sacculo-collic reflex assessed by the cervical vestibular-evoked myogenic potential.</p><p><strong>Settings and design: </strong>The current study used a cross-sectional study design.</p><p><strong>Materials and methods: </strong>A total of 80 participants were divided into four groups based on the history of PLD exposure. Each group consisted of 20 participants who underwent cervical vestibular-evoked myogenic potential (cVEMP) testing using alternating polarity 500 Hz tone bursts.</p><p><strong>Statistical analysis used: </strong>Analysis of variance (ANOVA) and Bonferroni post hoc test were used to obtain the statistically significant difference among the group.</p><p><strong>Results: </strong>The results showed that the amplitude of p1-n1 of cVEMP was significantly reduced in individuals with longer PLD exposure duration.</p><p><strong>Conclusion: </strong>The study suggests that listening to music through a PLD at high levels of volume controls could be deleterious to the vestibular well-being of an individual. The study highlights the importance of being aware of the adverse effects of using PLDs to prevent potential damage to the vestibular systems.</p>\",\"PeriodicalId\":19195,\"journal\":{\"name\":\"Noise & Health\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10747808/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Noise & Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/nah.nah_13_23\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Noise & Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/nah.nah_13_23","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
An Exploratory Study of Cervical Vestibular-Evoked Myogenic Potential in Users of Personal Listening Devices.
Context: The use of personal listening devices (PLDs) is becoming increasingly popular, particularly among young people. Numerous studies have demonstrated that being exposed to PLDs can have adverse effects on the auditory system. Owing to the similarities between the auditory and vestibular systems, it is possible that the negative effects of PLD use may extend to the vestibular system, an area that has not been extensively studied.
Aim: The study aimed to investigate the impact of exposure to PLDs on the vestibular system, specifically the sacculo-collic reflex assessed by the cervical vestibular-evoked myogenic potential.
Settings and design: The current study used a cross-sectional study design.
Materials and methods: A total of 80 participants were divided into four groups based on the history of PLD exposure. Each group consisted of 20 participants who underwent cervical vestibular-evoked myogenic potential (cVEMP) testing using alternating polarity 500 Hz tone bursts.
Statistical analysis used: Analysis of variance (ANOVA) and Bonferroni post hoc test were used to obtain the statistically significant difference among the group.
Results: The results showed that the amplitude of p1-n1 of cVEMP was significantly reduced in individuals with longer PLD exposure duration.
Conclusion: The study suggests that listening to music through a PLD at high levels of volume controls could be deleterious to the vestibular well-being of an individual. The study highlights the importance of being aware of the adverse effects of using PLDs to prevent potential damage to the vestibular systems.
Noise & HealthAUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
CiteScore
2.10
自引率
14.30%
发文量
27
审稿时长
6-12 weeks
期刊介绍:
Noise and Health is the only International Journal devoted to research on all aspects of noise and its effects on human health. An inter-disciplinary journal for all professions concerned with auditory and non-auditory effects of occupational, environmental, and leisure noise. It aims to provide a forum for presentation of novel research material on a broad range of topics associated with noise pollution, its control and its detrimental effects on hearing and health. It will cover issues from basic experimental science through clinical evaluation and management, technical aspects of noise reduction systems and solutions to environmental issues relating to social and public health policy.