用微传感器测量Hawley固位器的磨损时间与下颌弓的稳定性有关吗?

IF 1.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Ezgi Atik, Tulin Taner, Muge Aksu
{"title":"用微传感器测量Hawley固位器的磨损时间与下颌弓的稳定性有关吗?","authors":"Ezgi Atik,&nbsp;Tulin Taner,&nbsp;Muge Aksu","doi":"10.1007/s00056-023-00495-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to show a possible correlation between the mean wear time of Hawley retainers and long-term mandibular arch stability as assessed via wear time analysis with microsensors.</p><p><strong>Methods: </strong>This longitudinal retrospective study comprised 47 subjects (mean age 16.30 ± 1.06 years) having been treated with a nonextraction protocol and presenting moderate crowding at pretreatment. For retention, all patients were instructed to use a mandibular Hawley retainer for 12 months, and wear time was documented every 3 months during a posttreatment period of 6 months using TheraMon software. These individuals were divided into two groups. Those who adhered to a wear time equal to or more than 12 h/day (group 1A; N = 17) and those who complied for less than 12 h/day (group 2A; N = 30) were compared with respect to changes of the mandibular arch during the first 6 months of retention. Furthermore, a subgroup of 28 patients who completed a 12-month follow-up period were again divided into two groups: the individuals in group 1B (N = 12) adhered to a wear time equal to or more than 8 h/day, while those in group 2B (N = 16) complied for less than 8 h/day. Little's Irregularity Index, intercanine and intermolar widths, arch length, overjet, and overbite were measured on mandibular models taken at pretreatment (T0) and posttreatment (T1), as well as 6 months (T2) and 12 months (T3) after debonding. Pearson correlation test, independent samples t‑test, and Mann-Whitney U test were used for statistical evaluation.</p><p><strong>Results: </strong>From T1 to T2, group 1A and group 2A showed a significant relapse in intermolar width with a difference in the median value of 0.38 mm (p = 0.019). At the complete 12-month follow-up, the increase in Little's irregularity score was significantly greater in group 2B (2.54 ± 1.29 mm) than in group 1B (1.32 ± 1.03 mm; p = 0.012). The established wear time measurements showed significant negative correlations with the Little's irregularity score and overjet changes between T1 and T3 (p < 0.05).</p><p><strong>Conclusions: </strong>The results emphasized that the use of a retainer should not fall below a level of at least 8 h/day.</p>","PeriodicalId":54776,"journal":{"name":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2023-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Is wear time of Hawley retainers measured with microsensors related to mandibular arch stability?\",\"authors\":\"Ezgi Atik,&nbsp;Tulin Taner,&nbsp;Muge Aksu\",\"doi\":\"10.1007/s00056-023-00495-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to show a possible correlation between the mean wear time of Hawley retainers and long-term mandibular arch stability as assessed via wear time analysis with microsensors.</p><p><strong>Methods: </strong>This longitudinal retrospective study comprised 47 subjects (mean age 16.30 ± 1.06 years) having been treated with a nonextraction protocol and presenting moderate crowding at pretreatment. For retention, all patients were instructed to use a mandibular Hawley retainer for 12 months, and wear time was documented every 3 months during a posttreatment period of 6 months using TheraMon software. These individuals were divided into two groups. Those who adhered to a wear time equal to or more than 12 h/day (group 1A; N = 17) and those who complied for less than 12 h/day (group 2A; N = 30) were compared with respect to changes of the mandibular arch during the first 6 months of retention. Furthermore, a subgroup of 28 patients who completed a 12-month follow-up period were again divided into two groups: the individuals in group 1B (N = 12) adhered to a wear time equal to or more than 8 h/day, while those in group 2B (N = 16) complied for less than 8 h/day. Little's Irregularity Index, intercanine and intermolar widths, arch length, overjet, and overbite were measured on mandibular models taken at pretreatment (T0) and posttreatment (T1), as well as 6 months (T2) and 12 months (T3) after debonding. Pearson correlation test, independent samples t‑test, and Mann-Whitney U test were used for statistical evaluation.</p><p><strong>Results: </strong>From T1 to T2, group 1A and group 2A showed a significant relapse in intermolar width with a difference in the median value of 0.38 mm (p = 0.019). At the complete 12-month follow-up, the increase in Little's irregularity score was significantly greater in group 2B (2.54 ± 1.29 mm) than in group 1B (1.32 ± 1.03 mm; p = 0.012). The established wear time measurements showed significant negative correlations with the Little's irregularity score and overjet changes between T1 and T3 (p < 0.05).</p><p><strong>Conclusions: </strong>The results emphasized that the use of a retainer should not fall below a level of at least 8 h/day.</p>\",\"PeriodicalId\":54776,\"journal\":{\"name\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00056-023-00495-x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00056-023-00495-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是通过微传感器的磨损时间分析来评估Hawley固位器的平均磨损时间与长期下颌弓稳定性之间的可能相关性。方法:这项纵向回顾性研究包括47名受试者(平均年龄16.30 ± 1.06年),已经用非牵引方案治疗并且在预处理时呈现中度拥挤。对于固位,所有患者都被要求使用下颌Hawley固位器12个月,并使用TheraMon软件在6个月的治疗后每3个月记录一次佩戴时间。这些人被分成两组。那些坚持佩戴时间等于或超过12 h/天(第1A组;N = 17) 以及那些遵守规定不到12 h/天(2A组;N = 30)与在保留的前6个月期间下颌弓的变化进行比较。此外,完成12个月随访期的28名患者再次被分为两组:1B组(N = 12) 磨损时间等于或大于8 h/天,而2B组(N = 16) 符合8 h/天。在处理前(T0)和处理后(T1)以及脱粘后6个月(T2)和12个月(T3)的下颌模型上测量Little’s不规则指数、齿间和齿间宽度、弓长、外覆和覆牙。Pearson相关检验、独立样本t检验和Mann-Whitney U检验用于统计评估。结果:从T1到T2,1A组和2A组的分子间宽度明显复发,中位数相差0.38 毫米(p = 0.019)。在整个12个月的随访中,2B组的利特尔不规则评分的增加明显更大(2.54 ± 1.29 mm)比1B组(1.32 ± 1.03 mm;p = 0.012)。所建立的磨损时间测量结果显示,在T1和T3之间,与利特尔不规则性评分和overset变化呈显著负相关(p 结论:研究结果强调,保持器的使用不应低于至少8 h/天。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Is wear time of Hawley retainers measured with microsensors related to mandibular arch stability?

Is wear time of Hawley retainers measured with microsensors related to mandibular arch stability?

Purpose: The aim of this study was to show a possible correlation between the mean wear time of Hawley retainers and long-term mandibular arch stability as assessed via wear time analysis with microsensors.

Methods: This longitudinal retrospective study comprised 47 subjects (mean age 16.30 ± 1.06 years) having been treated with a nonextraction protocol and presenting moderate crowding at pretreatment. For retention, all patients were instructed to use a mandibular Hawley retainer for 12 months, and wear time was documented every 3 months during a posttreatment period of 6 months using TheraMon software. These individuals were divided into two groups. Those who adhered to a wear time equal to or more than 12 h/day (group 1A; N = 17) and those who complied for less than 12 h/day (group 2A; N = 30) were compared with respect to changes of the mandibular arch during the first 6 months of retention. Furthermore, a subgroup of 28 patients who completed a 12-month follow-up period were again divided into two groups: the individuals in group 1B (N = 12) adhered to a wear time equal to or more than 8 h/day, while those in group 2B (N = 16) complied for less than 8 h/day. Little's Irregularity Index, intercanine and intermolar widths, arch length, overjet, and overbite were measured on mandibular models taken at pretreatment (T0) and posttreatment (T1), as well as 6 months (T2) and 12 months (T3) after debonding. Pearson correlation test, independent samples t‑test, and Mann-Whitney U test were used for statistical evaluation.

Results: From T1 to T2, group 1A and group 2A showed a significant relapse in intermolar width with a difference in the median value of 0.38 mm (p = 0.019). At the complete 12-month follow-up, the increase in Little's irregularity score was significantly greater in group 2B (2.54 ± 1.29 mm) than in group 1B (1.32 ± 1.03 mm; p = 0.012). The established wear time measurements showed significant negative correlations with the Little's irregularity score and overjet changes between T1 and T3 (p < 0.05).

Conclusions: The results emphasized that the use of a retainer should not fall below a level of at least 8 h/day.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
64
审稿时长
>12 weeks
期刊介绍: The Journal of Orofacial Orthopedics provides orthodontists and dentists who are also actively interested in orthodontics, whether in university clinics or private practice, with highly authoritative and up-to-date information based on experimental and clinical research. The journal is one of the leading publications for the promulgation of the results of original work both in the areas of scientific and clinical orthodontics and related areas. All articles undergo peer review before publication. The German Society of Orthodontics (DGKFO) also publishes in the journal important communications, statements and announcements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信