川崎病儿童计算机断层扫描冠状动脉造影的辐射剂量分析。

Mahesh Chandra Bhatt, Manphool Singhal, Rakesh Kumar Pilania, Subhash Chand Bansal, Niranjan Khandelwal, Pankaj Gupta, Surjit Singh
{"title":"川崎病儿童计算机断层扫描冠状动脉造影的辐射剂量分析。","authors":"Mahesh Chandra Bhatt,&nbsp;Manphool Singhal,&nbsp;Rakesh Kumar Pilania,&nbsp;Subhash Chand Bansal,&nbsp;Niranjan Khandelwal,&nbsp;Pankaj Gupta,&nbsp;Surjit Singh","doi":"10.5409/wjcp.v12.i4.230","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is evolving role of computed tomography coronary angiography (CTCA) in non-invasive evaluation of coronary artery abnormalities in children with Kawasaki disease (KD). Despite this, there is lack of data on radiation dose in this group of children undergoing CTCA.</p><p><strong>Aim: </strong>To audit the radiation dose of CTCA in children with KD.</p><p><strong>Methods: </strong>Study (December 2013-February 2018) was performed on dual source CT scanner using adaptive prospective electrocardiography-triggering. The dose length product (DLP in milligray-centimeters-mGy.cm) was recorded. Effective radiation dose (millisieverts-mSv) was calculated by applying appropriate age adjusted conversion factors as per recommendations of International Commission on Radiological Protection. Radiation dose was compared across the groups (0-1, 1-5, 5-10, and > 10 years).</p><p><strong>Results: </strong>Eighty-five children (71 boys, 14 girls) with KD underwent CTCA. The median age was 5 years (range, 2 mo-11 years). Median DLP and effective dose was 21 mGy.cm, interquartile ranges (IQR) = 15 (13, 28) and 0.83 mSv, IQR = 0.33 (0.68, 1.01) respectively. Mean DLP increased significantly across the age groups. Mean effective dose in infants (0.63 mSv) was significantly lower than the other age groups (1-5 years 0.85 mSv, 5-10 years 1.04 mSv, and > 10 years 1.38 mSv) (<i>P</i> < 0.05). There was no significant difference in the effective dose between the other groups of children. All the CTCA studies were of diagnostic quality. No child required a repeat examination.</p><p><strong>Conclusion: </strong>CTCA is feasible with submillisievert radiation dose in most children with KD. Thus, CTCA has the potential to be an important adjunctive imaging modality in children with KD.</p>","PeriodicalId":75338,"journal":{"name":"World journal of clinical pediatrics","volume":"12 4","pages":"230-236"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/71/a5/WJCP-12-230.PMC10518747.pdf","citationCount":"0","resultStr":"{\"title\":\"Radiation dose analysis of computed tomography coronary angiography in Children with Kawasaki disease.\",\"authors\":\"Mahesh Chandra Bhatt,&nbsp;Manphool Singhal,&nbsp;Rakesh Kumar Pilania,&nbsp;Subhash Chand Bansal,&nbsp;Niranjan Khandelwal,&nbsp;Pankaj Gupta,&nbsp;Surjit Singh\",\"doi\":\"10.5409/wjcp.v12.i4.230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There is evolving role of computed tomography coronary angiography (CTCA) in non-invasive evaluation of coronary artery abnormalities in children with Kawasaki disease (KD). Despite this, there is lack of data on radiation dose in this group of children undergoing CTCA.</p><p><strong>Aim: </strong>To audit the radiation dose of CTCA in children with KD.</p><p><strong>Methods: </strong>Study (December 2013-February 2018) was performed on dual source CT scanner using adaptive prospective electrocardiography-triggering. The dose length product (DLP in milligray-centimeters-mGy.cm) was recorded. Effective radiation dose (millisieverts-mSv) was calculated by applying appropriate age adjusted conversion factors as per recommendations of International Commission on Radiological Protection. Radiation dose was compared across the groups (0-1, 1-5, 5-10, and > 10 years).</p><p><strong>Results: </strong>Eighty-five children (71 boys, 14 girls) with KD underwent CTCA. The median age was 5 years (range, 2 mo-11 years). Median DLP and effective dose was 21 mGy.cm, interquartile ranges (IQR) = 15 (13, 28) and 0.83 mSv, IQR = 0.33 (0.68, 1.01) respectively. Mean DLP increased significantly across the age groups. Mean effective dose in infants (0.63 mSv) was significantly lower than the other age groups (1-5 years 0.85 mSv, 5-10 years 1.04 mSv, and > 10 years 1.38 mSv) (<i>P</i> < 0.05). There was no significant difference in the effective dose between the other groups of children. All the CTCA studies were of diagnostic quality. No child required a repeat examination.</p><p><strong>Conclusion: </strong>CTCA is feasible with submillisievert radiation dose in most children with KD. Thus, CTCA has the potential to be an important adjunctive imaging modality in children with KD.</p>\",\"PeriodicalId\":75338,\"journal\":{\"name\":\"World journal of clinical pediatrics\",\"volume\":\"12 4\",\"pages\":\"230-236\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/71/a5/WJCP-12-230.PMC10518747.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World journal of clinical pediatrics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5409/wjcp.v12.i4.230\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World journal of clinical pediatrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5409/wjcp.v12.i4.230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:计算机断层扫描冠状动脉造影(CTCA)在无创评估川崎病(KD)儿童冠状动脉异常中的作用正在演变。尽管如此,缺乏这组接受CTCA的儿童的辐射剂量数据。目的:审计KD儿童CTCA的辐射剂量。方法:使用自适应前瞻性心电图触发在双源CT扫描仪上进行研究(2013年12月至2018年2月)。记录剂量-长度乘积(DLP,单位为毫格雷厘米mGy.cm)。根据国际辐射防护委员会的建议,通过应用适当的年龄调整转换系数来计算有效辐射剂量(毫西弗-mSv)。比较了各组(0-1、1-5、5-10和>10岁)的辐射剂量。结果:85名KD儿童(71名男孩,14名女孩)接受了CTCA。中位年龄为5岁(2个月至11岁)。DLP和有效剂量的中位数分别为21 mGy.cm,四分位间距(IQR)=15(13,28)和0.83 mSv,IQR=0.33(0.68,1.01)。各年龄组的平均DLP显著增加。婴儿的平均有效剂量(0.63 mSv)显著低于其他年龄组(1-5岁0.85 mSv、5-10岁1.04 mSv和>10岁1.38 mSv)(P<0.05)。其他组儿童的有效剂量没有显著差异。所有CTCA研究都具有诊断质量。没有孩子需要复试。结论:亚毫米波剂量的CTCA治疗大多数KD患儿是可行的。因此,CTCA有可能成为KD儿童的一种重要辅助成像方式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Radiation dose analysis of computed tomography coronary angiography in Children with Kawasaki disease.

Background: There is evolving role of computed tomography coronary angiography (CTCA) in non-invasive evaluation of coronary artery abnormalities in children with Kawasaki disease (KD). Despite this, there is lack of data on radiation dose in this group of children undergoing CTCA.

Aim: To audit the radiation dose of CTCA in children with KD.

Methods: Study (December 2013-February 2018) was performed on dual source CT scanner using adaptive prospective electrocardiography-triggering. The dose length product (DLP in milligray-centimeters-mGy.cm) was recorded. Effective radiation dose (millisieverts-mSv) was calculated by applying appropriate age adjusted conversion factors as per recommendations of International Commission on Radiological Protection. Radiation dose was compared across the groups (0-1, 1-5, 5-10, and > 10 years).

Results: Eighty-five children (71 boys, 14 girls) with KD underwent CTCA. The median age was 5 years (range, 2 mo-11 years). Median DLP and effective dose was 21 mGy.cm, interquartile ranges (IQR) = 15 (13, 28) and 0.83 mSv, IQR = 0.33 (0.68, 1.01) respectively. Mean DLP increased significantly across the age groups. Mean effective dose in infants (0.63 mSv) was significantly lower than the other age groups (1-5 years 0.85 mSv, 5-10 years 1.04 mSv, and > 10 years 1.38 mSv) (P < 0.05). There was no significant difference in the effective dose between the other groups of children. All the CTCA studies were of diagnostic quality. No child required a repeat examination.

Conclusion: CTCA is feasible with submillisievert radiation dose in most children with KD. Thus, CTCA has the potential to be an important adjunctive imaging modality in children with KD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信